Product Knowledge

An In-Depth Look at the Reaming Principle and Zero Expansion Stress Mechanism of Daring Undercut Anchors

Views: 0Posted on: 2026-10-09

The bottom line first:The core of the Daring undercut anchor's undercutting principle lies in"secondary reaming at the hole bottom plus mechanical interlock". A straight hole is drilled first with a hammer drill, then a specialized undercut drill bit reams the hole bottom a second time, forming a reverse-cone cavity that is larger at the bottom and smaller at the top. After the anchor is installed, the bottom key segments expand within the reverse-cone cavity, forming a rigid mechanical interlock with the cavity shoulder. This structure achieves"zero expansion stress"for three fundamental reasons: first, the undercut cavity provides space to accommodate the deformation of the expanding key segments; the segments do not "wedge open" against the straight-hole wall but "lock in" inside the cavity, so the radial compression on the hole wall approaches zero; second, the source of anchoring force shifts from the expansion anchor'sfriction-based load bearingto the undercut anchor'smechanical interlock load bearing. In terms of durability mechanisms, the undercut anchor relies purely on mechanical interlock load bearing, with

The undercut anchor is the safest class of mechanical anchor in post-installed anchoring works. Yet many people's understanding of its working principle stops at "knowing that reaming is needed", lacking a systematic understanding of how the mechanical interlock is actually established after undercutting and why it can eliminate expansion stress. This article provides an in-depth mechanical analysis of the Daring undercut anchor's undercutting mechanism and the path to zero expansion stress.

I. First, understand why expansion anchors have expansion stress

1.1 The anchoring logic of the expansion anchor: friction generated by "wedging"

The anchoring principle of the expansion anchor can be summarized in one sentence: friction generated by radial compression against the hole wall resists pull-out. During installation, applied torque pulls the threaded rod outward via the nut; the cone at the bottom of the rod compresses the expansion sleeve, wedging it radially outward against the hole wall. The reaction force of the hole wall on the expansion sleeve creates frictional resistance that prevents the anchor from being pulled out.

This principle involves an unavoidable physical fact: the magnitude of the anchoring force depends directly on the radial pressure the expansion sleeve exerts on the hole wall. Greater pressure means greater friction and higher anchoring force. But the radial pressure also pushes against the hole wall concrete—the greater the pressure, the higher the risk of the concrete being split open. This is an irreconcilable contradiction and the root of the inherent defect of expansion anchors.

1.2 Two failure paths of expansion stress in concrete

The radial expansion stress of an expansion anchor damages concrete through two paths. The first path isoutward pushing: when the anchor is close to the member's edge, the outward component of the radial stress pushes against the concrete edge, directly forming splitting cracks when edge distance is insufficient. The second path isinward compression: even when the anchor is far from the edge, the radial stress generates circumferential tensile stress around the hole wall; when the tensile stress exceeds the concrete's tensile strength, micro-cracks extend outward from the hole wall.

More critically, when an expansion anchor is subjected to external tension, the radial expansion stress does not decrease but ratherincreases with the tensile force. Research shows that the splitting force of a metal expansion anchor is proportional to the applied tensile force. Under extreme conditions such as wind vibration and earthquakes, tensile force increases suddenly, radial expansion stress surges accordingly, and concrete splitting can occur in an instant.

II. Breakdown of the Daring undercut anchor's undercutting principle

2.1 The critical first step: secondary reaming at the hole bottom forms a reverse-cone cavity

Installation of the Daring undercut anchor (also called the mould-undercut anchor or post-cut anchor) takes two steps. The first step is drilling a straight hole with a hammer drill; the second step uses thespecialized undercut drill bitto ream the hole bottom a second time, forming a reverse-cone cavity that is larger at the bottom and smaller at the top.

The existence of this reverse-cone cavity fundamentally changes how the anchor carries load. The expansion sleeve of an expansion anchor wedges open in astraight hole of constant diameter, with the sleeve compressed against the hole wall, so the expansion force with nowhere to be released acts entirely on the hole wall. The expansion elements of the undercut anchor, in contrast, expand in anundercut cavity of larger diameter, and the cavity provides space to accommodate the expansion deformation.

Daring supplies matching original undercut drill bits, available in square shank or round shank to fit different hammer drills. When the specialized undercut drill bit is used for secondary reaming, the undercut diameter and depth allow only positive deviation, not negative deviation, ensuring the undercut cavity is well-shaped and dimensionally precise.

2.2 The critical second step: key segments expand to form the mechanical interlock

After reaming, the anchor is placed in the hole, and the bottom key segments expand within the reverse-cone cavity through hammering or torque. Once expanded, the key segments lodge on the cavity shoulder, forming themechanical interlock。

. From a mechanics perspective, the load capacity of mechanical interlock is far higher than friction expansion. The expansion anchor relies on the friction between the expansion sleeve and the hole wall—a single frictional surface dependent on normal force and friction coefficient. The undercut anchor relies on thegeometric interlocking—to pull out the anchor, the key segments must be "sheared" out of the cavity or the cavity shoulder must "crumble", which requires overcoming the shear strength of the concrete rather than merely friction.

In the Daring undercut anchor, the key segments and the undercut cavity form a full-ring, reverse-undercut anti-withdrawal support expansion ring cut into the concrete surface. The interlock area is large and loading is uniform—this is the key to achieving high load capacity and seismic performance. Compared with the ring line contact of ordinary expansion anchors, the interlock loading of the undercut anchor issurface contact, with a more uniform stress distribution and no local stress concentration.

2.3 The fundamental change in load transfer path

When an expansion anchor is subjected to tension, the force transfers through the path cone head → expansion sleeve → hole wall, with radial stress increasing as tension increases. When an undercut anchor is subjected to tension, the force transfers through the path key segments → undercut cavity shoulder → deep concrete; the transfer path isaxial-shearrather thanradial-friction。

. All loads are transferred to the dense concrete deep at the hole bottom, with no radial expansion compression on the upper hole wall or at the hole opening. This load-bearing mode resembles the stress distribution effect of cast-in foundation bolts—cast-in inserts are safe precisely because their loads transfer directly into the interior of the concrete through the anchor plate rather than through hole wall friction.

III. How zero expansion stress is achieved: an in-depth analysis of the three mechanisms

3.1 First mechanism: the undercut cavity releases deformation space

This is thephysical basisfor achieving zero expansion stress. The expansion sleeve of an expansion anchor wedges open in a straight hole with no space to release the expansion deformation, so it all converts into radial pressure on the hole wall. The key segments of the undercut anchor expand within the undercut cavity, whose radial dimension is larger than the straight-hole section, giving the key segments sufficient space to complete their expansion deformation. The radial pressure generated when the key segments contact the cavity wall is distributed over the cavity's entire inner surface rather than concentrated on the narrow hole wall of the straight-hole section, greatly reducing radial stress per unit area.

3.2 Second mechanism: mechanical interlock replaces friction anchoring

This is themechanical basisfor achieving zero expansion stress. Anchoring force no longer depends on the friction generated by radial pressure but on the mechanical interlocking between the key segments and the cavity shoulder. The installation torque only needs to fully expand the key segments, far less than the "wedging tight" torque required by an expansion anchor. The drastic reduction in torque demand means the initial stress disturbance to the concrete during installation is also greatly reduced.

The installation torque of the Daring undercut anchor is strictly calibrated to the product specification and applied with a specialized torque wrench. During installation, hammering until the embedment depth line on the threaded rod is flush with the substrate surface indicates the anchor is fully installed; there is no need to rely on torque magnitude to judge the anchoring force.

3.3 Third mechanism: increased tension does not increase radial stress

This is the key to maintaining zero expansion stress in thelong-term service phase. The vicious cycle of the expansion anchor is: external tension increases → the cone head compresses the expansion sleeve → radial expansion stress increases → splitting risk rises. The undercut anchor breaks this chain—tension transfers directly through the key segments to the cavity shoulder, so increased tension does not cause increased radial stress. Even under extreme dynamic loads such as wind vibration and earthquakes, the hole wall and hole opening are not subjected to additional radial compression.

IV. Structural design of the Daring undercut anchor

4.1 Materials and sizes

Daring undercut anchor materials cover Class 5.8/8.8 carbon steel and 304/316 stainless steel, with sizes covering M8-M20. The products comply with the JGJ 145-2013 standard and are suitable for cracked and non-cracked concrete substrates from C20 to C60.

4.2 Key structural features

  • Key segment structure: The bottom key segments are precision machined; once expanded, they form a full-ring mechanical interlock cut into the concrete surface with the undercut cavity, with uniform loading.

  • Embedment depth line marking: The threaded rod has an embedment depth line marking; hammering until the line is flush with the substrate surface indicates full installation, with no additional measuring tools needed on site.

  • Thread design: The rod threads are precision machined and pass thread accuracy testing, ensuring fit accuracy with the mating nuts.

4.3 Supplied construction tools

Daring undercut anchors are supplied with original undercut drill bits, hammering sleeves, and powered installation tools. The undercut drill bits are available in square shank or round shank to fit different hammer drills. Daring provides original undercut drill bits matched to the undercut anchors proportionally, ensuring the reaming effect meets expectations. The load-bearing of an un-reamed hole and that after secondary reaming can differ by more than 3 times; without reaming, the load-bearing often fails to reach the design value—this is a hard criterion for judging whether the work is acceptable.

V. Performance verification of the Daring undercut anchor

5.1 Authoritative certifications

  • EU ETA certification: Passed by the back bolts, undercut anchors, and Anka anchors. ETA certification requires a full suite of tests covering tensile/shear load capacity, seismic performance, fatigue cycling, extreme salt spray corrosion, and cracked concrete suitability.

  • Class S anchor certification: The highest classification, suitable for cracked concrete and seismic zones.

  • 2-million-cycle fatigue test: Verifies reliability under long-term dynamic loads.

  • 120-minute fire resistance test: Verifies load capacity retention under fire and high-temperature conditions.

  • Seismic testing: Stable anchoring performance under high loads, vibration loads, and impact loads.

  • Salt spray testing, coating thickness inspection, elongation testing, and thread accuracy testing and more than ten other authoritative tests.

5.2 The essential difference in failure modes

Comparison dimensionExpansion anchorDaring undercut anchor
Load-bearing principleFriction anchoring—friction generated by radial compressionMechanical interlock—load transferred through geometric interlocking
Radial expansion stressLarge, and increases with tensile forceApproaches zero; the undercut cavity releases deformation space
Installation torque requirementHigh; the anchor must be "wedged tight" to anchorLow; the key segments only need to fully expand
Splitting riskHigh; splitting occurs easily with insufficient edge distance or spacingLow; suitable for small edge distances and small spacings
Cracked concrete suitabilityNot suitable—crack opening causes loss of anchoring forceSuitable—mechanical interlock does not rely on expansion force
Failure modeAnchor pull-out (brittle, no warning)Anchor rod fracture or concrete cone failure (ductile, with warning)

VI. Frequently asked questions

Q1What is the undercutting principle of the Daring undercut anchor?
A straight hole is drilled first with a hammer drill, then a specialized undercut drill bit reams the hole bottom a second time, forming a reverse-cone cavity that is larger at the bottom and smaller at the top. After the anchor is installed, the bottom key segments expand within the reverse-cone cavity and form a rigid mechanical interlock with the cavity shoulder—the mechanical interlock. Loads transfer through the path key segments → cavity shoulder → deep concrete, in an axial-shear mode rather than a radial-friction mode.
Q2How is zero expansion stress achieved?
Three mechanisms work together. First, the undercut cavity provides space to accommodate the expanding key segments, which "lock in" inside the cavity rather than "wedging open" against the straight-hole wall, so radial pressure is distributed over the cavity's inner surface. Second, the source of anchoring force shifts from friction-based load bearing to mechanical interlock, greatly reducing the installation torque requirement. Third, increased tension does not increase radial stress, breaking the failure chain of "tension → radial stress → splitting".
Q3What is the essential difference in load-bearing principle between undercut anchors and expansion anchors?
The expansion anchor relies on friction anchoring—the expansion sleeve wedges open in a straight hole and resists pull-out through friction with the hole wall, with radial expansion stress increasing as tension increases. The undercut anchor relies on mechanical interlock anchoring—the key segments expand in the undercut cavity and resist pull-out through geometric interlocking, requiring overcoming the concrete's shear strength rather than friction. The interlock structure does not depend on friction, so stable anchoring force is maintained even when the substrate cracks.
Q4What happens if an undercut anchor is installed without reaming?
Without reaming, the undercut anchor still works by expansion compression, functioning through the friction compression generated by ring line contact. Expansion stress becomes concentrated; when used in cracked concrete areas under long-term external loads, cracks gradually widen, causing anchor loosening and dynamic slippage. The load-bearing without reaming and that after secondary reaming can differ by more than 3 times, and pull-out tests usually fail outright.
Q5What are the features of the Daring undercut anchor's undercut drill bit?
Daring supplies original undercut drill bits matched to the undercut anchors proportionally to ensure the reaming effect meets expectations. The drill bits are available in square shank or round shank to fit different hammer drills. The undercut diameter and depth allow only positive deviation, not negative deviation. Reaming with the specialized undercut drill bit must use a pressurized straight-push method; wobbling eccentric drill reaming is not permitted.
Q6Which certifications has the Daring undercut anchor passed?
The Daring undercut anchor has passed more than ten authoritative tests including EU ETA certification, Class S anchor certification, the 2-million-cycle fatigue test, the 120-minute fire resistance test, seismic testing, coating thickness inspection, salt spray testing, elongation testing, and thread accuracy testing. Materials cover Class 5.8/8.8 carbon steel and 304/316 stainless steel, with sizes covering M8-M20.

The Daring undercut anchor adopts a deep-hole-bottom mechanical interlock design with no shallow expansion stress, and has passed Class S anchor certification and seismic testing, remaining safe and reliable even in small-edge-distance installations. Conventional undercut anchors can be used normally with a minimum edge distance of ≥3d, whereas expansion anchors usually require ≥8d-10d. Daring also offers a full chain of anchoring products including undercut anchors, self-undercutting anchors, chemical anchors, and back bolts, providing compliant anchoring solutions for demanding conditions such as load-bearing structures, cracked concrete, and seismic design zones. For undercut anchor selection calculations and construction technical guidance for specific projects, please contact the Daring technical team.

References

JGJ 145-2013 Technical Specification for Post-installed Anchors in Concrete Structures—Detailing and construction requirements for undercut-type anchors

GB 50367-2013 Design Code for Strengthening Concrete Structures—Provisions on the interlock effect of undercut anchors

JG/T 160-2017 Mechanical Anchors for Use in Concrete—Classification and technical requirements for mechanical anchors

Daring website—Why do ordinary expansion anchors split concrete? An in-depth breakdown of the zero expansion stress principle of undercut anchors

Daring website—Edge distance too small for expansion anchors? Undercut anchors have no expansion stress, so small-edge-distance installation is just as safe

Daring website—What are the differences between expansion anchors and undercut anchors? A thorough guide to choosing

Daring website—What is the difference between undercut anchors and self-undercutting anchors? Understanding how to choose in one article

Daring website—Why is the undercut anchor safer than both chemical anchors and expansion anchors? Five core advantages explained at once

Daring website—A complete guide to undercut mechanical anchor specifications and installation methods

Daring website—Mechanical anchor product range

Back to Daring Home  Back to Top