Conclusion first:An undercut mechanical anchor is asuitable for cracked and uncracked concretemechanical anchor that achievesBottom reaming forms a mechanical interlockanchoring, with advantages ofimmediate load bearing on installation, no waiting for curing, high load capacity and excellent seismic performance, with materials ofM8、M10、M12、M16、M20, with materials ofgrade 5.8 and 8.8 carbon steel(hot-dip galvanizing ≥45 μm) and304/316 stainless steel. Installation requiresDrilling → undercutting → hole cleaning → hammer-in installationFour-step process; it must be useddedicated undercutting drill bitanddriving sleeve. Daring undercut mechanical anchors have passed seismic tests at a building materials testing center and comply with JGJ 145-2013.
In building post-installed anchorage, the undercut mechanical anchor isload-bearing structure anchoringone of the compliant choices. Many designers and construction workers lack systematic understanding of the specifications and installation methods of undercut mechanical anchors, often resulting in wrong selection or improper construction. This article provides a comprehensive analysis in terms of specification parameters, performance data, installation steps and precautions.
I. Basic understanding of undercut mechanical anchors
1.1 What is an undercut mechanical anchor
An undercut mechanical anchor is also calledform-undercut anchor or post-cutting anchor, and refers to an anchor where, after a straight hole is drilled in the concrete base material, the bottom of the hole isreamed again, and the reamed cavity together with the expanded keys of the anchor form amutual locking mechanism, realizing the post-installed connection. Its load transfer takes the form ofmechanical interlock loading, independent of friction; the anchoring principle is similar to the stress distribution of cast-in foundation bolts.
The specification series of undercut anchors coversM8、M10、M12、M16、M20, with materials ofgrade 5.8 and 8.8 carbon steel(hot-dip galvanizing ≥45 μm) or304/316 stainless steel. Daring undercut anchors are supplied with original undercutting drill bits, driving sleeves and electric installation tools to ensure construction quality.
1.2 Load-bearing principle of undercut anchors
Undercut anchors are installed bypre-reaming the hole bottomso that the keys at the base of the anchor expand and formmechanical interlockwith the reamed cavity. This interlocking structuredoes not rely on friction, so stable anchoring force is maintained even if the base material cracks. In simple terms: an expansion anchor 'squeezes' into place, while an undercut anchor 'locks' into place — one relies on friction, the other on mechanical interlock.
II. Specification parameters of undercut mechanical anchors
2.1 Common sizes and installation parameters
| Specification model | Drilling diameter (mm) | Undercut diameter (mm) | Embedment depth (mm) | Applicable panel thickness (min) | Maximum installation torque (N·m) |
|---|---|---|---|---|---|
| M8 | 8 | 10.5 | 30 | 40 | 10 |
| M10 | 10 | 13.5 | 40 | 50 | 20 |
| M12 | 12 | 16 | 40 | 60 | 40 |
| M16 | 16 | 21 | 50 | 75 | 80 |
| M20 | 20 | 26 | 60 | 95 | 150 |
2.2 Material and corrosion protection options
Daring undercut mechanical anchors are available in the following materials:
Grade 5.8 carbon steel: suitable for general indoor environments, high cost-effectiveness
Grade 8.8 carbon steel: suitable for applications with higher load requirements, with higher strength
Hot-dip galvanized carbon steel: zinc coating thickness ≥45 μm, suitable for general outdoor environments
304 stainless steel (A2): suitable for outdoor exposed and humid environments
316 stainless steel (A4): suitable for coastal high-salt-spray and chemical corrosive environments
2.3 Reference load capacity values (C30 concrete)
| Size | Material grade | Design tensile load (kN) | Ultimate tensile load (kN) | Design shear load (kN) | Ultimate shear load (kN) |
|---|---|---|---|---|---|
| M8 | Grade 8.8 | 7.4 | 19.0 | 7.7 | 11.4 |
| M10 | Grade 8.8 | 12.8 | 30.2 | 12.6 | 18.1 |
| M12 | Grade 8.8 | 14.5 | 43.8 | 18.3 | 26.3 |
| M16 | Grade 8.8 | 28.9 | 70.9 | 34.6 | 49.0 |
| M20 | Grade 8.8 | 52.4 | 127.4 | 53.5 | 76.4 |
Note:The above data are reference values for C30 concrete with large spacing and large edge distances. Actual design values should be based on product test reports and structural design drawings.
III. Installation method of undercut mechanical anchors
3.1 Tools required for installation
The following special tools are required for installing undercut mechanical anchors:
Rotary hammer: for drilling and reaming; a rotary hammer with power ≥800 W is recommended
Straight-hole drill bit: straight-hole drill bit matching the anchor size
Undercutting drill bit: dedicated undercutting bit matching the anchor size (supplied by Daring)
Dust blower: for cleaning the hole and removing dust
Driving sleeve: for driving the anchor into the hole (supplied by Daring)
Torque wrench: for final tightening of the nut
3.2 Installation steps
Step 1: drilling
Use astraight-hole drill bitto drill a straight hole of the corresponding diameter and depth in the base material. Drilling depth should equal the embedment depth (see the specification parameter table). Pay attention to the following during drilling:
Drilling direction should be perpendicular to the base material surface, with perpendicularity deviation ≤2°
Drilling depth deviation should be controlled within +5 mm
If reinforcing steel is encountered, adjust the hole position appropriately; never cut main reinforcement forcibly
Step 2: undercutting (reaming)
Replace the straight-hole drill bit with adedicated undercutting drill bitand perform undercutting at the bottom of the hole. Undercut drilling is thekey process:
Insert the undercutting bit into the bottom of the straight hole and start the rotary hammer to ream
Undercut depth and diameter must be controlled strictly according to the specification parameters
If reinforcement is encountered during reaming and prevents expansion, especially for large-size anchors, adjust the hole position
After reaming, a wedge-shaped cavity should be formed at the bottom of the hole
Step 3: hole cleaning
Use adust bloweror compressed air to thoroughly clean dust from the hole:
Blow into the hole at least twice until no dust comes out
Installation is strictly prohibited when water or moisture is present in the hole
Incomplete cleaning will affect the interlocking effect between the anchor and the hole wall
Step 4: hammer-in installation
Place the anchor into the cleaned hole and use adriving sleevetogether with ahammerfor hammer-in installation:
Fit the driving sleeve over the anchor shank
Strike the driving sleeve with a hammer until the anchor sleeve is flush with the base material surface
Keep the striking direction consistent with the anchor axis during hammering
Avoid damage to the anchor from excessive hammering
Step 5: tightening and fixing
Once installed in place, use atorque wrenchaccording to themaximum installation torquein the specification parameter table to tighten the nut:
Tighten the nut to the design torque value
Avoid over-torque installation causing anchor damage or base material cracking
After tightening, anchoring is complete and the anchor can bear load immediately
IV. Installation precautions and common problems
4.1 Handling reinforcement encountered during reaming
Reaming is the stage most prone to problems in undercut anchor installation. If reinforcement is encountered, reaming cannot be completed, especially for large-size anchors (M20 and above). In such cases,adjust the hole position and re-drill and ream, and never cut reinforcement forcibly or install without reaming.
4.2 Direct installation without reaming strictly prohibited
If an undercut anchor is used as an expansion anchor (installed without reaming), its load performance is even worse than an expansion anchor— because undercut anchors have thicker walls that cannot expand. An undercut anchor must be reamed before it can deliver its proper anchoring performance. This is a common construction misconception and must be avoided.
4.3 Base material thickness requirements
Undercut anchors have a minimum base material thickness requirement. According to JGJ 145-2013, the embedment depth (h_eff) should satisfy:Base material thickness ≥ 1.5 × h_eff. See the specification parameter table for specific minimum base material thickness. When used in thin-slab structures, special attention must be paid to whether the base material thickness meets requirements.
4.4 Undercut anchors vs. self-undercutting anchors
Undercut anchors and self-undercutting anchors are both undercut mechanical anchors; the main differences are:
Undercut anchor: requires drilling a straight hole first and then reaming separately; more steps, but reaming is complete and the safety factor is high
Self-undercutting anchor: completes reaming during installation; simpler construction, but large sizes (M20 and above) are less common
The two have similar mechanical properties; the undercut anchor involves more steps but a higher safety factor, while the self-undercutting anchor is simpler to install but limited in size range.
V. Code basis
The design, production and installation of undercut mechanical anchors should meet the following code requirements:
JGJ 145-2013Technical Specification for Post-Installed Anchorage of Concrete Structures — anchor design and construction
GB 50367-2013Code for Design of Strengthening Concrete Structures — anchor selection for load-bearing structures
GB/T 16938-2008General Technical Conditions for Fasteners: Bolts, Screws, Studs and Nuts
GB/T 3098.1-2010Mechanical Properties of Fasteners: Bolts, Screws and Studs
VI. Frequently asked questions
| Q1 | What are the common sizes of undercut mechanical anchors? Common sizes include M6, M8, M10, M12, M16 and M20. Materials include grade 5.8 and 8.8 carbon steel (hot-dip galvanized) and 304/316 stainless steel. |
| Q2 | What special tools are needed for installing undercut anchors? A rotary hammer, straight-hole drill bit, dedicated undercutting drill bit, dust blower, driving sleeve and torque wrench are required. The undercutting bit and driving sleeve must be dedicated tools matched to the anchor size. |
| Q3 | Can undercut anchors be used directly without reaming? No. An undercut anchor installed without reaming performs even worse than an expansion anchor. It must be reamed before it can deliver its mechanical interlocking anchoring performance. |
| Q4 | What is the difference between undercut anchors and self-undercutting anchors? Undercut anchors require drilling a straight hole first and then reaming separately, involving more steps but a high safety factor; self-undercutting anchors complete reaming during installation, which is simpler but less common in large sizes (M20 and above). |
| Q5 | What tests have Daring undercut anchors passed? Daring undercut anchors have passed seismic tests at a building materials testing center, comply with JGJ 145-2013, and are supplied with original undercutting drill bits and driving sleeves. |
The Daring undercut mechanical anchor range covers M6-M20, with materials including grade 5.8 and 8.8 carbon steel (hot-dip galvanizing ≥45 μm) and 304/316 stainless steel, achieving mechanical locking withinstant lock on installation, no curing required, high load capacity, seismic and fatigue resistance, suitable for cracked/uncracked concrete, natural stone and other base materials. Daring supplies original undercutting drill bits, driving sleeves and electric installation tools, and its products comply with JGJ 145-2013, GB/T 16938-2008 and other standards. For undercut anchor selection and construction advice for specific projects, please consult the Daring technical team.
References
Daring website — undercut mechanical anchor product page
Daring website — differences between undercut anchors and expansion anchors
Daring website — how to use undercut mechanical anchors