The conclusion first:There is no uniform answer such as "how much is one set?" for curtain-wall anchoring systems; there is onlyComprehensive unit price per square metrebefore figures become comparable. The unit price consists of four parts — back bolts, pendants, substrate anchorage (cast-in channels or chemical/mechanical anchors), and auxiliary materials and testing — with typical shares of approximately 40%, 25%, 25%, and 10% respectively, though these vary widely between projects. What truly drives the total price apart are three variables:panel thickness and dimensions, wind pressure and building height, and corrosion-protection rating. Only when all five parameters are provided in the inquiry do the quotes become meaningfully comparable.
Scope of application:This article discussesback-bolt curtain walls with solid panelsThe unit price of the anchoring system material comprises back bolts, pendants, substrate anchors, and supporting auxiliary materials. The pricing of framing and structural sealant for framed glass curtain walls, the stiffener systems of aluminium panel curtain walls, and regional differences in installation labour and taxes are outside the scope of this article.
The most common mistake on site is to ask for the price of "curtain-wall anchoring" as if it were a standard part: send a photo, ask "how much is one set?", and then compare the figures from three suppliers. The result is often one quotes 80, one 45, and one 130 — a threefold difference on paper, when in fact the three are not pricing the same thing at all. Some quote only the back bolt itself, some include pendants but not substrate anchorage, some convert cast-in channels into chemical anchors, and some do not include pull-out testing or dedicated drilling tools in their quotes at all.
Worse still, this way of comparing prices steers procurement in the wrong direction: the supplier with the lowest figure is often precisely the onewith the narrowest scope. Once the contract is signed and the site starts requesting pendants, chemical anchors, and hole gauges, change orders are signed one after another, and the final settlement price turns out to be the highest of all. There is only one way to avoid this — break "one set" down into a granularity that can be aligned item by item, first unify the basis of comparison, and then compare the figures.
1. Why "how much is one set?" yields no usable answer
1.1 Mismatched units of measurement: "set", "piece", and "square metre" are three different things
The pricing basis for curtain walls issquare metre, because the design institute works in area, the client reviews area, and settlement is based on area. "Set" is retail language — the number of anchorage points on a panel and the number of components per point vary completely with different panel types and wind pressures. For the same 1200×600 panel, four-point hanging and four-edge support can differ twofold in component quantity; pricing by "set" sacrifices comparability from the very first day.
The correct conversion path is:Panel dimensions → number of anchorage points → number of pieces per square metre → unit price per square metre. If any link in this chain is not aligned, quotes cannot be compared. The table below lays out three common bases for comparison.
| Basis of pricing | Calculation basis | Advantages | Drawbacks | Applicable situations |
|---|---|---|---|---|
| By "set" | Anchoring components for a single panel | Fast quoting, convenient for small-batch procurement | Inconsistent boundaries; becomes invalid as soon as the panel type changes | Maintenance and occasional supplementary materials |
| By square metre | Number of pieces per m² × unit price | Consistent with design and settlement bases, allowing direct comparison | Panel type and wind-pressure parameters must be provided first | Tender pricing and cost estimation |
| By weight (tonnes) | Weight of steel / stainless steel | Linked to raw material market prices | Masks differences in processing and certification costs | Bulk sections and cast-in inserts |
1.2 The boundaries of "one set" are never uniform
Even for the same "one set", there are at least five different scopes: back bolt only; back bolt + pendant; back bolt + pendant + connecting bolt; any of the above plus substrate anchors; everything included with testing and technical services. The price differences between these five scopes are usually much greater than those between different manufacturers for the same scope. So the correct first step is not to bargain down the price, but towrite the scope into the inquiry first— when written clearly, a 30% price difference is a real difference and can be queried item by item; when written vaguely, a 30% price difference is merely a difference in basis and asking about it is pointless.
2. First calculate the quantity accurately: How many anchorage points per square metre
2.1 Deriving the number of points from panel dimensions
For solid-panel back-bolt curtain walls, the number of points is determined by the load-bearing configuration of the panel; common types include four-point hanging, four-point support, and six-point reinforcement. Larger, thinner panels and higher wind pressure require more points. A rough rule commonly used in engineering is:Keep the area carried per point within 0.36 m²(i.e. a coverage area of approximately 600×600); if exceeded, add points or increase panel thickness. This rule is not a code provision but a long-standing rule of thumb in the industry; the curtain-wall calculation report should govern for a specific project.
From this, the number of pieces per square metre can be derived in reverse: for a 1200×600 panel with four-point hanging, each panel is 0.72 m² with 4 points, equivalent to about 5.6 back bolts per m²; change the same panel to 900×600, each panel is 0.54 m² with 4 points, equivalent to about 7.4 back bolts per m². When the panel gets smaller but the number of points stays the same, the number of pieces per unit area actually increases — this is the arithmetic reason why "small panels are more expensive".
2.2 Quantity conversion table
| Panel specification (mm) | Area per panel (m²) | Common number of points | Back bolts / m² | Pendants / m² |
|---|---|---|---|---|
| 600×600 | 0.36 | 4 | Approx. 11.1 | Approx. 5.6–11.1 |
| 900×600 | 0.54 | 4 | Approx. 7.4 | Approx. 3.7–7.4 |
| 1200×600 | 0.72 | 4 | Approx. 5.6 | Approx. 2.8–5.6 |
| 1200×800 | 0.96 | 4~6 | Approx. 4.2–6.3 | Approx. 2.1–4.2 |
| 1500×750 | 1.125 | 6 | Approx. 5.3 | Approx. 1.8–3.6 |
The number of pendants in the table is given as a range because "one pendant per point" and "two pendants per panel" are two different constructions: in the former, the pendant carries the entire panel weight and wind load, while in the latter the load is transferred directly by the back bolts and the pendants serve only for positioning. With different constructions, pendant quantities differ by a factor of two, and this item is often the one most easily glossed over in quotes. This is also why two companies can quote completely different pendant quantities for the same drawings — not a calculation error, but a difference in interpretation.
3. Breaking down the four cost components item by item
3.1 Back bolts: Material is the biggest variable
The cost of back bolts is determined by three factors: specification (mainly M6/M8), material (304/316 stainless steel), and structural form (hammer-in/screw-in). A step up in specification raises the unit price by roughly one notch; switching material from 304 to 316 usually increases the unit price by more than 30%, with the exact figure fluctuating with current nickel and molybdenum prices; screw-in types cost more than hammer-in types because of additional machining steps. By value, back bolts account for about 40% of the anchoring system material cost, making them the heaviest of the four components.
3.2 Pendants: Form determines quantity, material determines unit price
Pendants fall into several categories including C-type, ear-type, and SE combination, with two material routes: aluminium alloy and stainless steel. C-type pendants involve higher machining costs and higher unit prices but offer good adjustability; ear-type pendants have a simple structure and good cost-effectiveness, with clear advantages in projects using large quantities; SE combination pendants balance adjustability and cost through a split design, but require more pieces. The unit price of a pendant is usually lower than that of a back bolt, but because 2–11 pieces are needed per square metre, the total amount often accounts for one quarter, making it the item most easily concealed by "per-piece pricing".
3.3 Substrate anchorage: Cast-in or post-installed, the difference lies in structure and schedule
This is the component with the greatest price fluctuation, because the solution itself can be changed: where cast-in installation is possible during construction of the main structure, use cast-in channels, priced per linear metre, with fewer pieces and fast installation; where the cast-in window has been missed, chemical anchors or undercut anchors must be installed individually, priced per set, in larger numbers and with additional costs for drilling and curing time. For the same wall, the material cost of the two solutions can differ by a factor of two, and the schedule difference is even greater. Therefore, before comparing prices, one must first confirm: does the quote correspond to cast-in or post-installed anchorage?
3.4 Auxiliary materials, tools, and testing: A small share that determines whether acceptance is possible
This accounts for about 10%, including dedicated drill bits, hole gauge rods and hole gauges, torque wrenches, pull-out test support, and documentation preparation. The amount is small, but it is a hard threshold in the acceptance process: whether undercutting at the bottom of the hole meets the standard must be checked batch by batch with a hole gauge, pull-out tests require batch sampling, and reports must be traceable to the test pieces and substrate. Remove this item from the quote and the money saved will eventually be spent on retesting and rework.
| Cost item | Typical share | Pricing unit | Main variables | Common ambiguities in quotes |
|---|---|---|---|---|
| Back bolt | Approx. 40% | CNY per piece | Specification, material, structural form | Not stating the material grade, only "stainless steel" |
| Pendant | Approx. 25% | CNY per piece | Form, material, number of pieces per point | Quoted as "one pendant per panel" when two points are actually required |
| Substrate anchorage | Approx. 25% | CNY per m or CNY per set | Cast-in / post-installed, specification, substrate | Omitting drilling and curing waiting time |
| Auxiliary materials and testing | Approx. 10% | CNY per item or CNY per window | Tool configuration and sampling batches | Writing "testing coordinated with the client" leaves responsibilities unclear |
4. Three variables affecting the total price
4.1 Panel thickness and dimensions
The thinner the panel, the more limited the embedment depth of the back bolt and the smaller the available specification, so points must be added for safety; the larger the panel, the greater the area carried per point, again requiring more points or larger specifications. The combined result of these two rules is:Thin panels + large panelsis the combination with the highest unit price, and many projects choose precisely this combination for façade aesthetics. If the budget is estimated only on the basis of standard panel types, this item will be the most seriously underestimated.
4.2 Wind pressure and building height
Wind pressure directly determines point density and substrate anchor specifications. In the same building, wind pressure at the podium and at the top of the tower can differ by more than a factor of two, with corresponding changes in the specification and quantity of anchors. Many problem quotes arise from multiplying the standard-floor unit price by the total area, ignoring the top reinforcement zone and corner areas — the quantity used in these two areas is often more than 1.5 times that of a standard floor. Negative wind pressure concentrates at corners; this is usually specifically marked on design drawings and should be priced separately in sections.
4.3 Corrosion-protection rating
For standard inland environments, 304 stainless steel is sufficient; coastal, industrial, and high-chloride environments require 316 or 316L, with a marked increase in unit price. For carbon steel components, coating thickness matters — hot-dip galvanizing and electro-galvanizing differ by an order of magnitude in both cost and service life. The corrosion-protection rating affects back bolts, pendants, and substrate anchors alike, and is the only variable that "raises prices across the board".
| Variable | Direction of change | Effect on unit price | Sensitivity |
|---|---|---|---|
| Panel thickness | 25mm → 20mm | Limited embedment depth → more points, smaller specifications | High |
| Panel dimensions | Larger area | More area per point → add points or increase thickness | Medium-high |
| Wind pressure / height | Greater height, corner areas | Denser points, upgraded substrate anchorage | High |
| Corrosion-protection rating | 304 → 316/316L | Material upgrade across the board | Medium (but the greatest impact on service life) |
5. Five parameters that must be provided in an inquiry
Include these five items in the inquiry and the spread between quotes will narrow immediately. If any item is missing, manufacturers can only fill in assumed values, and those assumptions differ from one to another — this is why the same drawings can produce widely different quotes.
| No. | Required parameter | Example entry | Consequence if omitted |
|---|---|---|---|
| 1 | Panel material and thickness | 25 mm granite | Back bolt specification and embedment depth cannot be determined |
| 2 | Standard panel dimensions and number of points | 1200×600, four-point hanging | Number of pieces per m² is pure guesswork |
| 3 | Basic wind pressure and building height | 0.45kN/m²,98m | Cannot price by zones; top areas are omitted |
| 4 | Corrosion-protection rating / environmental category | Coastal C4, 316 stainless steel | Quoted by default as 304, with later changes |
| 5 | Substrate type: cast-in or post-installed | Main structure already topped out, post-installed chemical anchors | Different solutions can differ by a factor of two in price |
6. Common misconceptions: Five actions that compare prices incorrectly
| Symptom | Consequence | Correct approach |
|---|---|---|
| Comparing only the unit price of back bolts | Ignoring pendants and substrate anchorage results in a higher total price instead | Compare using a unified comprehensive unit price per m² |
| Not asking for the material grade, only writing "stainless steel" | 304 and 316 are quoted together, planting hidden risks in coastal projects | Specify the grade and applicable standard in the contract and technical agreement |
| Multiplying the standard-floor unit price by the total area | Serious underestimation of top and corner reinforcement zones | Price by wind-pressure zones and sections |
| Quotes exclude testing and tools | Additions during acceptance raise the settlement price | Require testing support and a tool list to be itemized separately |
| Comparing cast-in and post-installed solutions on the same basis | Completely distorted conclusions and the wrong solution chosen | Determine the construction stage first, then compare prices within the same solution |
7. What Daring provides in this system
The Daring curtain-wall anchoring system covers seven product categories: back bolts, aluminium alloy pendants, angle brackets, cast-in channels, chemical anchors, mechanical anchors, and panel anti-fall systems. It can be quoted as a complete package of "back bolts + pendants + substrate anchorage", avoiding the blurred boundaries caused by multiple subcontractors. Back bolts use 304/316 stainless steel; undercut anchors and Anka anchors have passed EU ETA certification, and the company holds Class S certification and rare-earthquake seismic test reports at intensity 9. Certification and test documents can be attached directly to the quote for verification by the client and supervisor.
| Product | Material | Common specifications | Surface treatment | Applicable substrate / panel | Certification and testing | Supporting tools |
|---|---|---|---|---|---|---|
| Back bolts (hammer-in / screw-in) | 304/316 stainless steel | M6、M8 | Natural / passivated | Granite, ceramic panels, microcrystalline stone | ETA, rare-earthquake resistance at intensity 9, salt spray test | Dedicated drilling machine, hole gauge rod, hole gauge |
| Aluminium alloy pendant | 6063 series aluminium alloy | C-type / ear-type / SE combination | Anodized | Stone, ceramic panels | Material and mechanical property testing | Torque wrench, positioning fixtures |
| Cast-in channel | Carbon steel / stainless steel | Single C, double C | Hot-dip galvanized / hot-roll formed | Reinforced concrete (pre-cast embedment) | Load capacity and corrosion testing | T-head bolt, positioning accessories |
| Undercut / chemical anchor | Galvanized carbon steel / stainless steel | M8~M16 | Hot-dip galvanized / electro-galvanized | Cracked / uncracked concrete | ETA, Class S certification | Undercutting drill bit, hole-cleaning tools, pull-out tester |
The parameters in the table above are common configurations; load capacity and coating thickness for specific specifications are subject to the product parameter table and type test report. If only an order-of-magnitude estimate is needed for budgeting: taking 25 mm granite, normal wind pressure, and a C3 environment as an example, the anchoring system material cost usually ranges from several tens to just over one hundred yuan per square metre, with a two- to threefold spread; which end of the range applies depends on how the three variables above are combined.
8. Frequently asked questions
| Q1 | How much does one set of a curtain-wall anchoring system actually cost? There is no standard price. The proper question is "how much per square metre?", and it must be accompanied by the five conditions of panel thickness, panel dimensions, wind pressure, corrosion-protection rating, and cast-in or post-installed. Under different conditions, the unit price of the same wall can differ by more than a factor of two. |
| Q2 | Why is the unit price higher for small panels than for large ones? Because the panel becomes smaller while the number of points stays the same, the number of back bolts per square metre increases. A 600×600 panel works out to about 11 back bolts per m², while a 1200×600 panel needs only about 5.6; the number of pieces nearly doubles, so the unit price naturally rises. |
| Q3 | Which is more economical, cast-in channels or post-installed anchors? In terms of material cost, the former is usually more economical, because one channel replaces a row of back bolts; however, cast-in channels must be inserted during construction of the main structure, and if that window is missed, post-installation is the only option. The decision should be based not on unit price but on the construction stage and progress of the main structure. |
| Q4 | Should pull-out testing be included in the quote? It is advisable to list it separately. Testing is usually performed by a third party, but who bears the costs of sampling support, providing test pieces, and retesting must be stated clearly in the quote; otherwise repeated additions are likely during the acceptance stage. |
| Q5 | How much does the total price rise when switching from 304 to 316? For back bolts alone, the increase is usually more than 30%; including pendants and substrate anchors, the increase in total system price is somewhat smaller, because auxiliary materials and testing do not change with the material. The exact magnitude fluctuates with current nickel and molybdenum prices and should be quoted for the relevant period. |
| Q6 | Can we buy only the back bolts and source pendants and anchors from another manufacturer? Technically feasible, but attention must be paid to interface compatibility: the threads, bearing surfaces, and adjustment range of pendants and back bolts must be matched, and the specification of substrate anchors must fit the slotted holes of the pendants. Money saved by separate purchasing is often spent on rework at the interfaces. |
Returning to the original question: how much is one set? The answer is not a single number but a formula —Number of pieces per m² × unit price × four cost components. The number of pieces is determined by panel type and wind pressure, the unit price by material and specification, and the four components by the procurement boundary. Separate these three layers and comparing quotes changes from "who is lowest" to "who is right"; if they cannot be separated, the lowest quote often turns out to be the most expensive in the end. The Daring curtain-wall anchoring system can be quoted as a complete package of back bolts, pendants, and substrate anchorage, with parameter tables, certification documents, and supporting tool lists provided for direct entry into a comparison sheet. For quantity estimation and price breakdown for a specific project, please consult the Daring technical team.
References
JGJ 133-2001 Technical Code for Engineering of Metal and Stone Curtain Walls — Back-bolt connection and anchorage detail requirements for stone panels
JGJ 102-2003 Technical Code for Engineering of Glass Curtain Walls — Load values and calculation principles for supporting structures
JGJ 145-2013 Technical Specification for Post-installed Anchorage in Concrete Structures — Design, construction, and acceptance provisions for post-installed anchorage
GB 50210-2018 Standard for Acceptance of Construction Quality of Building Decoration — Acceptance of curtain-wall sub-projects and division of inspection batches
Daring website — Which products are included in the Daring curtain-wall anchoring system solution
Daring website — Differences in cost and application between cast-in channels and plate inserts
Disclaimer:The technical parameters, construction details, and assessment methods set out in this article are compiled on the basis of current national standards, industry codes, and product type test reports, and are provided as a reference for technical selection. The anchorage design, connection calculations, and acceptance criteria for a specific project should be reviewed and determined by a suitably qualified design institute in light of actual project conditions; actual product performance is subject to the parameter table and type test report for the corresponding batch. This article does not replace the design documents and technical agreement for a specific project.