Conclusion first:Subway cast-in channel construction must strictly comply withTB/T 3329-2013, Cast-in Channels for Tunnel Catenary of Electrified RailwaysandT/CAMET 02002-2019, Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transitand other standards. Core quality requirements include: channel material not lower thanQ345B/Q355B, and pass the 1,200-hour salt spray test, with weld quality grade70-80μmnot lower than class IIand pass the 1,200-hour salt spray test, with weld quality gradeand on dedicated fixtures, with construction subject toDrilling → hole cleaning → installation → fixing → acceptancefive steps; after concrete curing is completed, asampling test of load capacity(sampling at 1‰). Daring cast-in channels strictly comply with the above standards, with materials covering Q355 steel and 304/316 stainless steel, and both welded and riveted processes available. They have passed multiple tests including 2 million-cycle fatigue resistance and fire resistance.
In subway tunnels and urban rail transit projects, cast-in channels are key embedded components for the secure fixing of catenary systems, pipelines and equipment. Their construction quality directly affects operational safety and service life. Many construction workers lack systematic understanding of the construction codes and quality requirements for subway cast-in channels, often resulting in wrong selection or improper construction. This article provides a comprehensive analysis in terms of the code system, construction process, quality inspection and acceptance standards.
I. Code system for subway cast-in channel construction
1.1 Core codes and standards
The design, production and construction of subway cast-in channels are mainly based on the following codes:
TB/T 3329-2013Cast-in Channels for Tunnel Catenary of Electrified Railways — railway industry standard, specifying terms and definitions, classification, technical requirements, test methods, inspection rules, packaging and marking of cast-in channels. Similar channels used in urban rail transit may refer to this standard.
T/CAMET 02002-2019Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit — group standard of the China Urban Rail Transit Association, applicable to design selection, product testing and cast-in construction of channels and sleeves in reinforced concrete structures of urban rail transit projects.
GB/T 38525-2020Cast-in Channel Components for Building Curtain Walls — national standard, specifying classification, requirements and test methods of cast-in channel components.
Local and group standards: various regions have also issued relevant standards, such as Jiangsu Province'sDB32/T 5169-2025Technical Specification for Application of Channel Systems in Urban Rail Transit Engineering; Shenzhen City'sSJG 214-2025Technical Specification for Cast-in Channels and Sleeves in Rail Transit; Shandong Province'sT/SDRTS 003-2022Technical Specification for Cast-in Channels in Urban Rail Transit, etc.
1.2 Key points of the 2023 amendment to TB/T 3329
TB/T 3329-2013 wasin September 2023technically revised through Amendment No. 1. The main revisions include:
Material optimization: channel material optimized toQ355B low-alloy steelor specific stainless steel
Improved welding quality: weld quality grade changed fromgrade I to not lower than grade II, with the reference standard for welding processes updated accordingly
Stricter corrosion protection requirements: added1,200-hour salt spray testand other technical indicators
II. Material quality requirements
2.1 Material requirements
According to TB/T 3329-2013 and related standards, cast-in channel materials should meet the following requirements:
The channel steel and anchor rod materials should be consistent
Rimmed steel must not be used
Mechanical property indicators must not be lower than the provisions for Q345B in GB/T 1591, and elongation after fracture must not be less than 14%
Carbon content must not exceed 0.20%, and carbon equivalent must not exceed 0.44%
After revision, the material was optimized toQ355B low-alloy steelor specific stainless steel
Daring cast-in channels are made ofQ355 steelor304/316 stainless steel, strictly meeting the above material requirements.
2.2 Corrosion protection requirements
Cast-in channels are embedded in concrete for the long term, so corrosion resistance is critical:
Hot-dip galvanized coating thickness: the hot-dip galvanized coating thickness of cast-in embeds is generally required to be ≥70-80μm
Salt spray test: the 2023 revision requires the hot-dip galvanized coating to pass the1,200-hour neutral salt spray test
Stainless steel material: for special corrosive environments such as coastal high salt spray, select304 or 316 stainless steelMaterial
Daring cast-in channels use hot-dip galvanized corrosion protection for carbon steel, with coating thickness meeting standard requirements; 304/316 stainless steel options are also available for different corrosive environments.
2.3 Weld quality requirements
The connection between the channel and anchor rods is a key link in cast-in channel quality:
Connection method: the connection between channel and anchor rods may usewelding or mechanical connection
Weld quality grade: weld quality should comply with GB 50017, withquality grade not lower than class II
Fixture requirements: welding should be performed ondedicated fixturesto prevent side bending, torsion and thermal deformation
Stress relief: after welding, surface stress relief should be carried outat the weld area
Welding process: may useCO2 or argon gas-shielded weldingand other processes
Daring cast-in channels offerwelded and rivetedprocesses; welding is carried out strictly according to the code. The riveting process avoids welding heat effects, giving stable product quality and good seismic and fatigue resistance.
III. Construction process and quality requirements
3.1 Pre-construction preparation
The following preparations should be completed before construction:
Incoming acceptance: conduct visual, dimensional and galvanized coating thickness inspections on arriving cast-in channels and keep incoming acceptance records
Construction plan: prepare a dedicated construction plan specifying cast-in position, elevation, positioning accuracy and other requirements
Fixture preparation: prepare positioning fixtures, fixing clamps and other auxiliary tools
3.2 Positioning and fixing
The positioning accuracy of cast-in channels directly affects subsequent equipment installation:
Positioning requirements: determine the cast-in channel'sposition, elevation and orientation
Fixing method: bywelding or tyingfix the cast-in channel to the structural reinforcement to ensure no displacement during concrete pouring
Perpendicularity control: the channel should beperpendicularto the formwork surface; inclined embedding will affect installation of T-head bolts
Anti-clogging measures: the channel interior should be filled withfoam and end capsto prevent concrete slurry from entering and clogging the channel
3.3 Concrete pouring and curing
Pay attention to the following during concrete pouring:
Pouring protection: avoid direct contact between the vibrator and the cast-in channel during pouring to prevent displacement or damage
Concrete strength: the applicable concrete strength grade range for cast-in channel systems isC25-C80
Curing requirements: cure the concrete according to code requirements and do not disturb the cast-in channel during curing
3.4 Construction error control
Construction errors of cast-in channels should be controlled within allowable ranges:
Position deviation: deviation between the channel centerline and the design position should comply with design requirements
Elevation deviation: deviation of the channel top elevation should be within the allowable range
Angular deviation: perpendicularity deviation between the channel and the formwork surface should meet code requirements
IV. Quality inspection and acceptance standards
4.1 Incoming inspection
The following inspections should be carried out when cast-in channels arrive on site:
Visual inspection: mainly visual inspection; where necessary, a magnifier of no more than 10× may be used
Dimensional inspection: measure key dimensions with a vernier caliper with accuracy of 0.02 mm
Angular inspection: cut thin slices along the direction perpendicular to the length by wire cutting and measure with a universal tool microscope
Galvanized coating thickness: measured with a coating thickness gauge
4.2 In-process inspection
The following inspections should be carried out during construction:
Positioning inspection: check whether the position, elevation and perpendicularity of the cast-in channel meet design requirements
Fixing inspection: check whether the channel is firmly fixed to the reinforcement
Anti-clogging inspection: check that the foam and end caps inside the channel are intact
4.3 Acceptance of main control items
After concrete curing is completed, the following main control items should be accepted for the cast-in channels:
Load capacity test: cast-in channels embedded in concrete should be subjected totensile, shear and sliding load capacitytesting
Sampling quantity: the contractor samples1‰
Inspection method: apply load up to the design load capacity using loading equipment
Embedding inspection: check whether the cast-in channel is embedded in place
4.4 Main test items
According to TB/T 3329-2013, the main test items for cast-in channels include:
Visual and dimensional inspection: channel dimensions (W, H, C, D, F), T-head bolt dimensions (α, X)
Mechanical property test: single-anchor stud tensile load, double-anchor stud tensile load, shear working load, deflection test
T-head bolt test: T-head bolt load capacity, standard tightening torque test, allowable sliding load along the channel axis
Fatigue performance: fatigue test on precast concrete specimens
Fire resistance: fire resistance duration test
Corrosion resistance: salt spray test, galvanized coating thickness measurement
Torsion measurement: angular inspection
V. Daring subway cast-in channel solutions
5.1 Product advantages
Daring cast-in channels are produced strictly in accordance with TB/T 3329-2013, GB/T 38525-2020 and other standards, with the following advantages:
Reliable materials: Q355 steel or 304/316 stainless steel, with mechanical properties meeting code requirements
Diverse processes: offeringwelded and rivetedprocesses available
Durable corrosion protection: hot-dip galvanized corrosion protection, with coating thickness meeting standard requirements
Three-dimensional adjustment: flexible three-dimensional adjustment with matching T-head bolts
Comprehensive testing: passed multiple tests including 2 million-cycle fatigue resistance and fire resistance
5.2 Application scenarios
Daring cast-in channels are widely used in:
Subway tunnels: catenary suspension, pipeline supports, equipment fixing
Urban utility corridors: pipeline supports, electromechanical equipment installation
Building curtain walls: curtain wall framing connections
Rail transit: platform screen doors, safety facility fixing
Cast-in channels are installed before concrete pouring, requiring no on-site drilling and causing no damage to concrete reinforcement, effectively avoiding the safety risks of post-installed embeds.
VI. Frequently asked questions
| Q1 | What codes apply to subway cast-in channel construction? Mainly TB/T 3329-2013, Cast-in Channels for Tunnel Catenary of Electrified Railways, and T/CAMET 02002-2019, Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit. Similar channels used in urban rail transit may refer to TB/T 3329-2013. |
| Q2 | What weld quality grade is required for cast-in channels? According to TB/T 3329-2013 and its 2023 amendment, weld quality between the channel and anchor rods should comply with GB 50017, with a quality grade not lower than class II. Welding should be performed on dedicated fixtures to prevent side bending, torsion and thermal deformation. |
| Q3 | What are the corrosion protection requirements for cast-in channels? Carbon steel should be protected by hot-dip galvanizing, with coating thickness generally ≥70-80 μm. The 2023 revision requires passing a 1,200-hour neutral salt spray test. For special corrosive environments, 304/316 stainless steel should be selected. |
| Q4 | How is quality acceptance carried out after cast-in channel installation? After concrete curing, cast-in channels should be tested for tensile, shear and sliding load capacity. The contractor samples at 1‰ and inspects by applying load up to the design load capacity with loading equipment. |
| Q5 | Are Daring cast-in channels suitable for subway projects? Yes. Daring cast-in channels strictly comply with TB/T 3329-2013, GB/T 38525-2020 and other standards, using Q355 steel or 304/316 stainless steel, with welded and riveted processes available. The products have passed multiple tests including 2 million-cycle fatigue resistance and fire resistance, and are widely used in subways, utility corridors and curtain walls. |
Daring cast-in channels strictly comply with TB/T 3329-2013, GB/T 38525-2020 and other standards, using Q355 steel or 304/316 stainless steel, with welded and riveted processes available. The products have passed multiple tests including 2 million-cycle fatigue resistance and fire resistance at the national building materials testing center, and enable flexible three-dimensional adjustment with matching T-head bolts. For cast-in channel selection and construction advice for specific projects, please consult the Daring technical team.
References
Daring website — welded cast-in channel product page
Daring website — riveted cast-in channel product page
Daring website — cast-in channel product series
TB/T 3329-2013, Cast-in Channels for Tunnel Catenary of Electrified Railways, and Amendment No. 1
T/CAMET 02002-2019, Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit
GB/T 38525-2020, Cast-in Channel Components for Building Curtain Walls
GB 50017, Standard for Design of Steel Structures