In short:For the embedment depth of back bolts in 25mm-thick granite, the code requirement isno less than 12.5mm (1/2 of the panel thickness) and preferably no more than 16.7mm (2/3 of the panel thickness). From a practical engineering perspective,15mm is the most commonly used safe depth— this depth both meets the lower code limit and preserves a 10mm remaining thickness at the hole bottom; it also corresponds to Daring's two standard specifications, M6×15 and M8×15, requiring no customization and offering the shortest delivery time. Daring engineers recommend that for 25mm-thick granite, preference be given toM8×15 hammer-in back bolt(embedment depth 15mm), with installation torque controlled at 8-10 N·m. Daring hammer-in back bolts are made of 304/316 stainless steel and have passed Tongji University's 9-degree rare earthquake seismic test (acceleration 1.24g), making them a safe choice for dry-hung 25mm-thick granite.

25mm-thick granite is one of the most commonly used specifications in stone curtain walls. Embedment depth is the most critical parameter determining the load capacity of a back bolt—if it is too shallow, the interlock cannot form effectively; if it is too deep, the remaining thickness at the hole bottom is insufficient and cracking is likely. Many designers and construction personnel lack a systematic understanding of the question of 'how deep to drill exactly for 25mm thickness.' This paper provides practical answers from Daring engineers across four dimensions: code basis, safe depth calculation, matching Daring specifications, and construction control.

I. Code Basis for the Embedment Depth of Back Bolts in 25mm-Thick Granite

1.1 Core Code Clauses

According to the relevant provisions of DB32/T 4065-2021 Technical Standard for Building Curtain Wall Engineering and JGJ 133-2001 Technical Code for Metal and Stone Curtain Wall Engineering, back bolt connection details should comply with the following requirements:

The embedment depth of a back bolt should be no less than 1/2 of the stone panel thickness and preferably no more than 2/3 of the stone thickness. For double-cut back bolts, the remaining thickness from the bottom of the hole to the panel surface should be no less than 6mm; for other types of back bolts, the remaining thickness from the bottom of the hole to the panel surface should be no less than 10mm, and the bottom of the hole should be reamed.

For 25mm-thick granite, calculated according to this code:

  • Minimum embedment depth:25mm × 1/2 = 12.5mm

  • Maximum embedment depth:25mm × 2/3 ≈ 16.7mm

  • Remaining thickness requirement at the hole bottom: should be no less than 10mm

1.2 Why the Embedment Depth Cannot Be Less Than 12.5mm

The anchoring force of a back bolt comes from the mechanical interlock formed after reaming at the bottom of the hole. When the embedment depth is insufficient, the engagement area between the expansion segment and the reamed groove at the bottom of the hole is inadequate, so the interlock structure cannot form effectively and the load capacity is substantially reduced.

According to the base material load capacity verification formula for undercut back bolts, the anchoring tensile capacity is proportional to the effective embedment depth raised to the 1.5 power. When the effective embedment depth is less than 15mm, a reduction factor of 0.8 for shallow holes must also be applied. This means that for 25mm-thick granite, if the hole is drilled only to 12.5mm (just at the lower code limit), the load capacity is already in the critical zone requiring reduction. When drilled to 15mm, however, the load capacity has an ample safety margin.

1.3 Why the Embedment Depth Cannot Exceed 16.7mm

Excessive embedment depth means the remaining thickness at the hole bottom is too small. If 25mm-thick granite is drilled to 16.7mm, the remaining thickness at the hole bottom for a non-double-cut back bolt is only 8.3mm, below the 10mm required by the code. When the remaining thickness is insufficient, stress concentrates in the hole-bottom area during installation or under load, easily causing the panel to crack or spall at the hole bottom.

II. 15mm — The Safest Practical Depth for 25mm-Thick Granite

2.1 Why 15mm

Within the code-permitted range of 12.5mm to 16.7mm, 15mm is theoptimal depthrecommended by Daring engineers for three reasons:

  • Sufficient load capacity: an embedment depth of 15mm is above the critical value for shallow-hole reduction (15mm), so the 0.8 reduction factor is not needed and the load capacity can be calculated at its standard value.

  • Safe remaining thickness: after deducting the 15mm embedment depth from the 25mm panel thickness, the remaining thickness at the hole bottom is 10mm, just meeting the code requirement for non-double-cut back bolts; the panel will not crack due to an overly thin hole bottom.

  • Standard specifications, no customization required: 15mm corresponds to Daring's two standard specifications, M6×15 and M8×15, which are readily available on the market at reasonable prices with no need to wait for customization.

2.2 Comparison of Load Capacity Across Different Specifications

Daring hammer-in back bolts are commonly available in M6 and M8; taking a 15mm embedment depth as an example:

SpecificationEmbedment depthDesign value of tensile load capacityDesign value of shear load capacityInstallation torque
M6×1515mm≥11.5 kN≥6.4 kN4-6 N·m
M8×1515mm≥20.9 kN≥11.9 kN8-10 N·m

The design tensile load capacity of M8×15 is 1.82 times that of M6×15, and its design shear load capacity is 1.86 times that of M6×15. For 25mm-thick granite, if the panel is large or the wind load is high, M8×15 is recommended as the first choice.

2.3 Practical Recommendations from Daring Engineers

Daring has been deeply engaged in the field of building anchoring for more than 20 years, and the practical experience accumulated in numerous granite curtain wall projects is as follows:for 25mm-thick granite, drilling to an embedment depth of 15mm and using M8×15 hammer-in back bolts is currently the most mature and safest configuration in engineering practice. After drilling, use Daring's supplied hole-gauge rod to check the hole depth and the hole gauge to verify that reaming is properly completed.

III. Consequences of Insufficient or Excessive Embedment Depth

3.1 Insufficient Embedment Depth (<12.5mm)

  • The mechanical interlock cannot form effectively: the engagement area between the expansion segment and the reamed groove at the bottom of the hole is insufficient, so the interlock structure cannot be established.

  • Load capacity drops precipitously: when the effective embedment depth is less than 15mm, the 0.8 shallow-hole reduction factor must be applied, further reducing the load capacity.

  • The failure mode changes to pull-out failure: in the pull-out test, the back bolt is pulled out directly rather than the panel failing in a cone, which is a brittle failure without warning.

  • High scatter in load-bearing capacity: when the embedment depth is equal to or less than 12mm, there is considerable scatter in load-bearing failure, making it impossible to accurately assess the actual anchoring force by calculation.

3.2 Excessive Embedment Depth (>16.7mm)

  • Insufficient remaining thickness at the hole bottom: a remaining thickness of ≥10mm is required; after drilling 16.7mm into a 25mm panel, the remaining thickness is 8.3mm, below the code requirement.

  • Increased risk of panel cracking: when the remaining thickness is insufficient, stress concentrates in the hole-bottom area during installation or under load, easily causing the panel to crack or spall at the hole bottom.

  • Risk of drilling through the panel: if drilling is not properly controlled in 25mm-thick granite, a hole depth of more than 17mm may penetrate the panel completely.

IV. Key Construction Control Points for Back Bolts in 25mm-Thick Granite

4.1 Drilling Accuracy Control

The deviation in drilling depth for 25mm-thick granite should be controlled within±0.5mm. Drilling too deep reduces the remaining thickness at the hole bottom, while drilling too shallow results in insufficient embedment depth.

Daring supplies dedicated back bolt drilling machines and matching diamond bits, with drilling depths of 7-70mm and drilling diameters of 10-20mm, which can meet the drilling needs of 25mm-thick granite. Daring also provides a dedicated back bolt drilling service; its workers all have more than 5 years of skilled drilling experience, and on-site guidance can be provided.

4.2 Reaming Quality Control

Reaming is the key step in forming the mechanical interlock of an undercut back bolt. Reaming must be carried out a second time using a dedicated undercutting bit to form a well-shaped reverse-cone cavity. Only positive tolerances are allowed for the undercut diameter and depth; negative tolerances are not permitted.

Daring is uniquely equipped with hole-gauge rods and hole gauges, used respectively to check whether the hole depth is acceptable and whether reaming is properly completed. Generally, one check is required for every 30-50 holes; in high-intensity seismic design zones or important projects, every hole should be inspected.

4.3 Installation Torque Control

The installation torque for back bolts in 25mm-thick granite must be applied strictly in accordance with the product technical parameter table:

  • M6×15: installation torque 4-6 N·m

  • M8×15: installation torque 8-10 N·m

Too little torque prevents the back bolt from expanding fully, resulting in insufficient anchoring force; too much torque may damage the panel or cause cracking at the hole bottom. Daring supplies dedicated impact sockets and torque wrenches to ensure precise and controllable construction quality. Tightening in two steps is recommended: first pre-tighten to 50% of the specified torque, then tighten evenly to the final torque value.

4.4 Verification by Pull-Out Testing

The pull-out test is the ultimate means of judging the quality of the embedment depth. The test load for non-destructive inspection should reach 1.2 times the design value, with a stable load-holding time of no less than 2 minutes and a drop in the load reading of no more than 5% within those 2 minutes. If, in the pull-out test, the back bolt is pulled out directly rather than the panel failing in a cone, this indicates insufficient embedment depth or inadequate reaming, and the point is judged as failed.

V. Frequently Asked Questions

Q1What embedment depth is safest for back bolts in 25mm-thick granite?
The code requires an embedment depth of no less than 12.5mm (1/2 of the panel thickness) and preferably no more than 16.7mm (2/3 of the panel thickness). Daring engineers recommend 15mm in practice as the safest depth—it is above the shallow-hole reduction threshold (15mm), leaves a 10mm remaining thickness at the hole bottom that meets the code requirement, and corresponds to Daring's two standard specifications, M6×15 and M8×15, with no customization required.
Q2Should M6 or M8 back bolts be selected for 25mm-thick granite?
M8×15 is recommended as the first choice. The design tensile load capacity of M8×15 is ≥20.9 kN and its design shear load capacity is ≥11.9 kN, which are 1.82 times and 1.86 times those of M6×15, respectively. The installation torque is 8-10 N·m. If the panel is small or the wind load is low, M6×15 can also meet the requirements, with an installation torque of 4-6 N·m.
Q3What should the drilling depth deviation be controlled to for back bolts in 25mm-thick granite?
The drilling depth deviation should be controlled within ±0.5mm. Drilling too deep reduces the remaining thickness at the hole bottom and increases the risk of panel cracking; drilling too shallow results in insufficient embedment depth and reduced load capacity. Use Daring's supplied hole-gauge rod to inspect every hole; in high-intensity seismic design zones or important projects, every hole should be inspected.
Q4What is the remaining thickness at the hole bottom when the embedment depth is 15mm?
Subtracting the 15mm embedment depth from the 25mm panel thickness gives a remaining thickness at the hole bottom of 10mm. For back bolts, the code requires the remaining thickness at the hole bottom to be no less than 10mm, so this just meets the requirement.
Q5What certifications and test reports do Daring back bolts have for use in 25mm-thick granite?
Daring hammer-in back bolts have fully passed Tongji University's 9-degree rare earthquake seismic test, with an acceleration of 1.24g. Daring back bolts, undercut anchors, and Anka anchors have all passed EU ETA certification. Daring can provide mechanical properties test reports (tensile strength, yield strength, elongation, thread accuracy), material analysis reports (confirmation of 304/316 stainless steel), salt spray test reports, and more. Every shipment is accompanied by a quality certificate whose number corresponds one-to-one with the test report.

The Daring back bolt series covers hammer-in, screw-in, cast-in, and high-load back bolts, made of 304/316 stainless steel. Through mechanical locking, it achieves stress-free dry-hung anchoring of exterior wall panels and is paired with dedicated drilling machines and 6063-T6 aluminium alloy pendants. The Daring back bolt dry-hung cladding system has fully passed Tongji University's 9-degree rare earthquake seismic test, with an acceleration of 1.24g, and back bolts, undercut anchors, and Anka anchors have all passed EU ETA certification. For technical guidance on back bolt embedment depth calculation and drilling accuracy control for specific projects, please consult the Daring technical team.

References

JGJ 133-2001 Technical Code for Metal and Stone Curtain Wall Engineering — design provisions for back bolt connections

DB32/T 4065-2021 Technical Standard for Building Curtain Wall Engineering — Clause 7.4.21 on back bolt connection detailing requirements

JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures — testing and acceptance of anchoring load capacity

Daring website — What is the appropriate embedment depth for back bolts in 20mm-thick granite? Code basis and selection guide

Daring website — What to do when back bolt embedment depth is insufficient? Code requirements and solutions

Daring website — How to select the back bolt specification and model for stone dry-hung cladding

Daring website — What is the back bolt installation torque value? How to control construction quality with a torque wrench

Daring website — How much does the load capacity differ between M8 and M6 back bolts? A selection guide

Daring website — Back bolt product series

Back to Daring Home  Back to Top