Product Knowledge

What embedment depth is right for back bolts in 20 mm granite? Code basis and selection guide

Views: 0Posted on: 2026-08-31

Conclusion first:The recommended embedment depth for back bolts in 20 mm thick granite is10-13mm, with the specific value determined comprehensively based on panel strength, curtain wall height, wind load and other factors. According to code requirements, the back bolt embedment depth must not be less than1/2, and preferably not more than2/3. By this calculation, the embedment depth range for 20 mm thick granite is10mm-13.3mm。Screw-in back bolts are recommended as the preferred choice, with the specification ofM6×10 or M6×12, with material recommended as304 or 316 stainless steel. A 20 mm thick panel is of medium thickness; hammer-in back bolts generate high impact stress during installation, which can easily cause panel cracking or damage, thereforehammer-in back bolts are not recommended. During construction, note that theremaining thickness must not be less than 10 mm, the hole bottom must be reamed, and unreamed back bolt connections are strictly prohibited. Daring offers a full range of back bolts with matching drilling machines and hole-gauge tools to meet dry-hung anchoring needs for panels of different thicknesses.

In back bolt stone curtain wall projects, determining the embedment depth is a key link directly affecting curtain wall safety. Too shallow an embedment results in insufficient connection strength between the back bolt and the panel, with a risk of detachment; too deep an embedment weakens the effective panel thickness and may cause cracking at the hole. As a common panel thickness in stone curtain walls, the appropriate embedment depth for 20 mm thick granite has always been a focus of designers and construction workers. This article provides a systematic analysis in terms of code requirements, calculation formulas, model recommendations and construction points.

I. Code basis for back bolt embedment depth

1.1 Core code requirements

According toTechnical Standard for Building Curtain Wall Engineering, DB32/T 4065-2021clause 7.4.21 andTechnical Code for Engineering of Panel Curtain Walls, JGJ 336-2016the relevant provisions, the embedment depth of back bolts should meet the following requirements:

  • The back bolt embedment depth must not be less than 1/2 of the stone panel thickness, and preferably not more than 2/3 of the stone thickness

  • double-cut back boltsmust have a remaining thickness from hole bottom to panel surface of not less than 6 mm, while for other back bolt types the remaining thickness from hole bottom to panel surfacemust not be less than 10 mmof the panel thickness, the hole bottom must be reamed

  • and unreamed back bolt connections are strictly prohibited, and the machining accuracy of the back bolt hole must be inspected during installation

  • Back bolts should be made of stainless steel not lower than06Cr17Ni12Mo2 (S31608) austenitic stainless steel, with a diameter of not less than 6 mm

1.2 Embedment depth calculation formula

According to code requirements, the embedment depth of a back bolt can be determined by the following formula:

  • Minimum embedment depth= panel thickness × 1/2

  • Maximum embedment depth= panel thickness × 2/3

For 20 mm thick granite: minimum embedment depth = 20 × 1/2 =10mm; maximum embedment depth = 20 × 2/3 ≈13.3mm. Therefore, for 20 mm thick granite, the back bolt embedment depth should be controlled10-13mmwithin this range.

II. Back bolt selection recommendations for 20 mm thick granite

2.1 Back bolt type selection — why screw-in rather than hammer-in

A 20 mm thick granite panel isof medium thickness, and particular attention must be paid to the effect of installation stress on the panel when selecting the back bolt type:

  • Screw-in back bolt: the expansion sleeve expands slowly byrotating the shank, with noimpact stress during installation, making it very panel-friendly. Screw-in back bolts can be installed in panels as thin as10 mm minimum, making them very suitable for 20 mm thick granite. Daring holds the patent for screw-in back bolts and has improved the machining process so the expansion tabs on the bolt head are very uniform in thickness, with a higher product pass rate than similar products on the market.

  • Hammer-in back bolt: installed byhammering, which generates significant impact stress. Although 20 mm thick granite has high hardness, it is a brittle material, and hammering stress can easily causemicrocracks or even cracking. Hammer-in back bolts are mostly used forthick panels above 25 mmand are not recommended for 20 mm thickness.

Therefore, for 20 mm thick granite,screw-in back bolts are recommended as the preferred choiceto ensure the panel is not damaged by impact during installation. Screw-in back bolts expand slowly by rotation, forming a controllable stress-free anchoring structure that better protects the panel.

2.2 Recommended back bolt models

Based on the principle that embedment depth should be 1/2 to 2/3 of panel thickness, the recommended back bolt models for 20 mm thick granite are as follows:

Panel thicknessEmbedment depthRecommended back bolt modelRecommended back bolt type
20mm10mmM6×10Screw-in
20mm12mmM6×12Screw-in
20mm13mmM6×13 (custom)Screw-in
25-30mm15mmM6×15/M8×15Hammer-in / screw-in

Note:Data in the table refer to Daring's recommended back bolt models for stone dry-hung cladding. M6×10 and M6×12 are relatively standard models, while M6×13 and above usually require customization. Daring can provide custom-size back bolts to project requirements.

2.3 Material selection

Back bolt material should be selected according to the project environment:

  • 304 stainless steel: suitable for general indoor and outdoor environments, high cost-effectiveness

  • 316 stainless steel: suitable for harsh environments such as coastal high salt spray and chemical corrosion

The code requires back bolts to be made of material not lower than06Cr17Ni12Mo2 (S31608) austenitic stainless steel, and 316 stainless steel is preferred to ensure long-term durability.

III. Construction points for back bolts in 20 mm thick granite

3.1 Drilling accuracy control

The machining accuracy of the back bolt hole directly affects anchoring performance. Taking an M6 screw-in back bolt as an example:

  • Straight hole diameter: should follow the technical requirements of the screw-in back bolt product

  • Undercut diameter: should follow the technical requirements of the screw-in back bolt product

The drilling depth in 20 mm thick granite should match the embedment depth (10-13 mm); during construction, use adedicated back bolt drilling machine, to ensure drilling accuracy. Daring offers a fully automatic benchtop twin-head back bolt drilling machine with drilling depth up to 7-70 mm and drilling diameter 10-20 mm.

3.2 Reaming requirements

The code explicitly stipulates thatthe hole bottom must be reamed, and the use of unreamed back bolt connections is strictly prohibited. Reaming is the key process for forming the mechanical interlock of a back bolt; inadequate reaming will prevent effective anchoring. Daring's uniquehole-depth gauge rodcan check whether the back bolt hole depth is acceptable, and the matchinghole gaugecan measure whether reaming is in place.

3.3 Remaining thickness requirement

For 20 mm thick granite, theremaining thickness from the bottom of the back bolt hole to the panel surface must not be less than 10 mm. This means:

  • At 10 mm embedment, remaining thickness = 20 - 10 =10mm(meets requirement)

  • At 12 mm embedment, remaining thickness = 20 - 12 =8mm(does not meet requirement)

Therefore, for 20 mm thick granite, to ensure a remaining thickness ≥10 mm, the embedment depth should be keptwithin 10 mm. However, if adouble-cut back boltis used, the remaining thickness requirement can be relaxed to 6 mm, allowing an embedment depth up to 14 mm. It is recommended to confirm the remaining thickness requirement according to the specific back bolt type selected.

IV. Frequently asked questions

Q1What is the appropriate embedment depth for back bolts in 20 mm thick granite?
According to code requirements, the embedment depth should not be less than 1/2 of the panel thickness (10 mm) and preferably not more than 2/3 (13.3 mm). M6×10 or M6×12 screw-in back bolts are recommended, with an embedment of 10-12 mm. To ensure a remaining thickness ≥10 mm, an embedment of 10 mm is recommended.
Q2Should screw-in or hammer-in back bolts be used for 20 mm thick granite?
Screw-in back bolts are recommended. A 20 mm thick granite panel is of medium thickness; hammer-in back bolts generate high impact stress during installation, easily causing cracking or damage. Screw-in back bolts are installed by rotation with no impact stress and are panel-friendly.
Q3What is the remaining thickness requirement for back bolt holes in 20 mm thick granite?
For other back bolt types, the remaining thickness from the bottom of the hole to the panel surface must not be less than 10 mm. Double-cut back bolts can be relaxed to 6 mm. Confirm the requirement according to the specific back bolt type selected.
Q4What material should be used for back bolts in 20 mm thick granite?
304 or 316 stainless steel is recommended. The code requires back bolts to be made of austenitic stainless steel not lower than 06Cr17Ni12Mo2 (S31608). For general environments 304 stainless steel is sufficient; for harsh environments such as coastal high salt spray, 316 stainless steel should be selected.
Q5Does Daring offer screw-in back bolts suitable for 20 mm thick granite?
Yes. Daring holds the patent for screw-in back bolts and offers standard sizes such as M6×10 and M6×12 as well as custom sizes. Daring also provides matching fully automatic benchtop twin-head back bolt drilling machines and inspection tools such as hole-depth gauge rods and hole gauges.

The Daring back bolt range covers hammer-in, screw-in, cast-in and high-load back bolts, made of 304/316 stainless steel, achieving stress-free dry-hung anchoring of exterior wall panels through mechanical locking. Daring holds the patent for screw-in back bolts and has improved the machining process so that the expansion tabs on the bolt head are very uniform in thickness. Daring provides matching fully automatic benchtop twin-head back bolt drilling machines and dedicated inspection tools such as hole-depth gauge rods and hole gauges to help construction workers precisely control drilling quality. For back bolt selection and construction advice for specific projects, please consult the Daring technical team.

References

Daring website — how to select back bolt specifications for stone dry-hung cladding

Daring website — how to choose back bolts for curtain wall dry-hung cladding

Daring website — a discussion of the unimplemented JGJ 133-2013 back bolt code

JGJ 336-2016, Technical Code for Engineering of Panel Curtain Walls

DB32/T 4065-2021, Technical Standard for Building Curtain Wall Engineering

General industry technical standard for back bolts — embedment depth of 1/2 to 2/3 of panel thickness

Back to Daring Home  Back to Top