Here is the conclusion first:Undercut anchors (mold-undercut anchors) and self-undercutting anchors (self-cutting anchors) are both undercut-type mechanical anchors, and they are the only two undercut anchor types available for curtain wall load-bearing structures. Their core difference lies in thethe only two availableundercut anchor types. The core difference between them lies in theundercutting method: undercut anchors require a specialized undercut bit toream the hole a second timebefore installation — the process is more complex but the anchorage is more complete. Self-undercutting anchors, during installation, use their own cutting heads tocomplete the undercut and installation simultaneously, making installation easier. For small sizes (such as M12), the mechanical performance of the two is close; at larger sizes, undercut anchors offer better load capacity. Self-undercutting anchors are available up to M20, while undercut anchors generally stop at M16.Load-bearing structures must use undercut-type anchors (undercut or self-undercutting); expansion anchors are strictly prohibited.
In post-installed anchoring of buildings, undercut anchors and self-undercutting anchors are the two most commonly used undercut-type mechanical anchors. Many designers and installers often “can't tell them apart” — their applications are similar, but their usage differs greatly. This article provides a systematic comparison across definition, installation methods, available sizes, mechanical performance, safety performance, and other dimensions.
1. Basic definitions of undercut anchors and self-undercutting anchors
1.1 Undercut anchors (mold-undercut anchors)
An undercut anchor (also known as amold-undercut anchor, post-cut anchor, or pre-reamed anchor) is produced by first drilling a straight hole into a concrete base material with a rotary hammer and then using aspecialized undercut drilling bitto ream the bottom of the hole a second time, forming a wedge-shaped hole that is wider at the bottom and narrower at the top. The anchor is then inserted, and hammering or torque opens the expansion segments at the bottom of the anchor, forming aninterlock effectwith the step at the bottom of the undercut, achieving mechanical anchorage.
The undercut anchor is a highly mature product among building anchors, with excellent load capacity and seismic performance. Daring undercut anchors are made of carbon steel of grade 5.8 or higher, or 304/316 stainless steel.
1.2 Self-undercutting anchors (self-cutting anchors)
A self-undercutting anchor (also known as aself-cutting anchor or self-reaming anchor) is an anchor whose expansion element carrieshard cutting edges(diamond or tungsten carbide). During installation, the installation rod on the rotary hammer engages the slot on the anchor's expansion sleeve and rotates while hammering, so thatthe undercut and the embedding of the expansion element are completed simultaneouslywith anchor installation, without any separate reaming step.
Self-undercutting anchors have an anchoring mechanism similar to that of undercut anchors, only without the separate reaming operation, and their safety performance is also good; they are currently one of the most widely used anchor types. Daring self-undercutting anchors are made of carbon steel of grade 5.8 or higher, or 304/316 stainless steel.
2. The core differences between undercut and self-undercutting anchors
| Comparison dimension | Undercut anchor (mold-undercut) | Self-undercutting anchor (self-cutting) |
|---|---|---|
| Installation method | Drill a straight hole →secondary reaming with a specialized bit→ install the anchor | Drill a straight hole →undercutting and installation completed simultaneously(no separate reaming required) |
| Installation complexity | Higher(requires a specialized undercut bit; more steps) | Lower(can be installed with a rotary hammer; saves time and effort) |
| Undercut size (M12 example) | Undercut size reaches M24 | Relatively small undercut size |
| Probability of hitting rebar | Higher(large undercut size) | Lower(no separate reaming required) |
| Largest size available | Generally only up toM16 | Up toM20 |
| Small-size load capacity (M12) | Bothvery close(both fail by anchor steel fracture) | Bothvery close(both fail by anchor steel fracture) |
| Large-size load capacity | Superior | Slightly below undercut anchors |
| Undercut quality | Better(complete pre-reaming; full expansion) | Fair (only partially cuts through the concrete) |
| Pull-out test failure mode | Anchor steel fracture or concrete cone failure | Anchor steel fracture or concrete cone failure |
| Suitability for cracked concrete | Suitable(has an interlock effect) | Suitable(has an interlock effect) |
| Suitability for load-bearing structures | Suitable | Suitable |
3. Installation methods in depth
3.1 Undercut anchors: secondary reaming
Installing an undercut anchor takes three steps:
- Step 1: drill a straight hole in the concrete base material with a rotary hammer
- Step 2: use aspecialized mold-undercut toolto perform the secondary reaming with a straight pressing motion (pressed vertically down from the hole opening)
- Step 3: place the anchor into the undercut hole and apply torque to expand the segments at the bottom of the anchor, forming aninterlock effect
The pre-reaming operation for undercut anchors allows the anchor to expandmore fullyafter installation; in pull-out tests, the anchor is almost never pulled out directly.
3.2 Self-undercutting anchors: simultaneous undercutting
Self-undercutting anchors are even simpler to install:
- Step 1: drill a straight hole with a rotary hammer
- Step 2: place the anchor into the hole; the installation rod on the rotary hammer engages the slot on the anchor's expansion sleeve,rotating and hammering
- Step 3: the cutting head at the bottom of the anchor (set with diamond or tungsten carbide edges)completes the undercut simultaneouslyduring installation, forming the interlock effect
Self-undercutting anchorsrequire no separate reaming, which saves considerable labor hours, and they can be installed with a rotary hammer, making the work very easy.
3.3 The two forms of self-undercutting anchors
Self-undercutting anchors on the market mainly come in two forms:
- Diamond-head type: excellent undercutting performance, but expensive, and the single-use heads inevitably create waste
- Mechanical-mechanism type: achieves self-undercutting by adjusting the withdrawal height, the taper, and the sleeve slot design; simple to install, but only partially cuts the concrete, so the undercut quality is somewhat lower
4. Mechanical performance comparison
4.1 Small sizes (M12): the two are close
For small sizes such as M12, undercut and self-undercutting anchors havevery similar tension capacity. When an M12 anchor reaches an embedment depth of 80mm, even in grade 8.8 carbon steel, the pull-out test result isanchor steel fracture. Actual demand for M12 undercut anchors accounts formore than 60%of the total, making it the workhorse size in this field.
The most commonly used undercut anchor model isM12×80×125(M12 refers to the threaded rod outer diameter, 80 to the embedment depth, and 125 to the overall length); this model is relatively well balanced in all respects.
4.2 Large sizes: undercut anchors are better
At larger sizes,the mechanical performance of undercut anchors is superior to that of self-undercutting anchors. The main reason is that the pre-reaming operation allows the undercut anchor to expandmore fullyafter installation, producing a more complete interlock effect.
This also explains why undercut anchors are preferred in large-size applications — their anchorage is more reliable and their load capacity higher.
4.3 Seismic performance: the unique advantage of undercut anchors
The ultimate load capacity of undercut anchors (both undercut and self-undercutting) isessentially unaffected by dynamic loading, giving them excellent seismic performance. This is one of the core advantages that set undercut-type anchors apart from expansion anchors and chemical anchors — the ultimate load capacity of expansion anchors and chemical anchors decreases to varying degrees under dynamic loads.
Therefore, in structures in seismic design zones and in members subject directly to dynamic loads,undercut-type anchors must be used, and expansion anchors must not be used.
5. Differences in available sizes
5.1 Undercut anchors: limited size range
Installing an undercut anchor requires secondary reaming, and the undercut size is large. Taking an M12 undercut anchor as an example, its undercut size reachesM24, making it relatively easy to hit rebar during installation. This imposes a major limitation on the size range of undercut anchors —most manufacturers only produce undercut anchors up to M16.
5.2 Self-undercutting anchors: a richer size range
For self-undercutting anchors, since there is no separate reaming step, theprobability of hitting rebar is comparatively lower. As a result, self-undercutting anchors are available in sizes up toM20。
However, when using large-size anchors, it is advisable to first learn the rebar layout in the concrete in order to devise a sensible drilling plan.
6. Code requirements for load-bearing structures
According to Article 16.1.3 of GB 50367-2013, Design Code for Strengthening Concrete Structures:
- Mechanical anchors used in load-bearing structures must be undercut anchors with an interlock effect. Based on their construction, these anchors are further divided intoself-undercutting and mold-undercut typesas well as the adhesive-mold-undercut type — three types in total
- Adhesive anchors used in load-bearing structures must be special reverse-cone adhesive anchors
According to Article 16.1.4 of GB 50367-2013:
- In structures in seismic design zones and in members subject directly to dynamic loads, expansion anchors must not be used as connections in load-bearing structures
In brief:Load-bearing structures must use undercut-type anchors (undercut or self-undercutting); expansion anchors are strictly prohibited.
7. Selection decision guide
Situations favoring undercut anchors
- Extremely high load capacity requirements: undercut anchors expand more fully and offer better mechanical performance
- Large-size anchors (M16 and above): undercut anchors offer better load capacity at large sizes
- Pursuing the highest safety factor: complete pre-reaming delivers a more reliable interlock effect
- Curtain wall load-bearing structures: the anchor type preferred by the code
Situations favoring self-undercutting anchors
- Installation efficiency as the priority: no separate reaming required; can be installed with a rotary hammer, saving time and effort
- Avoiding rebar: self-undercutting anchors are less likely to hit rebar
- Large sizes needed (M16-M20): undercut anchors generally stop at M16, while self-undercutting anchors reach M20
- Small sizes (M12) for routine projects: the two have similar mechanical performance, and self-undercutting anchors are easier to install
8. Frequently asked questions
| Q1 | Which is better, an undercut anchor or a self-undercutting anchor? There is no absolute “better” — it depends on the application. At small sizes (M12), the mechanical performance of the two is close, and self-undercutting anchors are easier to install; at large sizes, undercut anchors offer better load capacity. If the highest safety factor is the goal, undercut anchors are reamed more completely and anchor more reliably; if installation efficiency is the goal, self-undercutting anchors save more time and effort. |
| Q2 | Is the load capacity gap large between M12 undercut and self-undercutting anchors? No. The tension capacity of M12 undercut and self-undercutting anchors is very close. When an M12 anchor reaches an embedment depth of 80mm, even in grade 8.8 carbon steel, the pull-out test result is anchor steel fracture. Demand for this size accounts for more than 60% of the undercut anchor total. |
| Q3 | Why are large-size undercut anchors hard to find on the market? Installing an undercut anchor involves a large secondary undercut; for M12, the undercut size reaches M24, making it easy to hit rebar. As a result, the size range of undercut anchors is severely limited, and most manufacturers only produce M16 and below. Self-undercutting anchors, with no separate reaming step, are available up to M20. |
| Q4 | Can undercut and self-undercutting anchors be used in load-bearing structures? Yes. GB 50367-2013 states explicitly: mechanical anchors used in load-bearing structures must be undercut anchors with an interlock effect (including self-undercutting, mold-undercut, and adhesive-mold-undercut types). Both are undercut-type anchors and both can be used in load-bearing structures; expansion anchors are strictly prohibited. |
| Q5 | What undercut anchor products does Daring offer? Daring offers a full range of undercut anchors and self-undercutting anchors, made of carbon steel of grade 5.8 or higher or 304/316 stainless steel. Undercut anchors offer superior load capacity and seismic performance and are suitable for curtain wall load-bearing structures; self-undercutting anchors are quick to install and available in a richer size range (up to M20), commonly used in all kinds of undercut anchoring scenarios. For undercut anchor selection advice on a specific project, please contact the Daring technical team. |
Daring offers a full range of undercut anchors and self-undercutting anchors, made of carbon steel of grade 5.8 or higher or 304/316 stainless steel. Undercut anchors offer superior load capacity and seismic performance and are suitable for curtain wall load-bearing structures; self-undercutting anchors are quick to install and available in a richer size range (up to M20), commonly used in all kinds of undercut anchoring scenarios. For undercut anchor selection advice on a specific project, please contact the Daring technical team.