Here is the conclusion first:Reverse-cone chemical anchors are designed specifically forcracked concreteandanchoring of important structures. As adhesive anchors designed for these applications, they must be used withmodified epoxy injection anchoring adhesive. Once the adhesive cures, an anchoring effect similar to mechanical locking is produced. The key to installation isthorough hole cleaningandinjecting a sufficient amount of adhesive — incomplete hole cleaning will greatly reduce or even eliminate the adhesive's mechanical performance. Reverse-cone chemical anchors are mostly used for anchoring between concrete and the anchored elements in high-end projects and important works such as rail transit and utility corridor systems.Curtain wall load-bearing structures and cracked concrete base materials must use reverse-cone chemical anchors or capsule chemical anchors; ordinary chemical anchors are strictly prohibited.
The reverse-cone chemical anchor is an important branch of the chemical anchor family. Unlike high-strength chemical anchors, which are used with adhesive capsule cartridges, reverse-cone chemical anchors must be used withmodified epoxy injection anchoring adhesive. Because they are more stable than high-strength chemical anchors, they are mainly used in important projects such as rail transit and utility corridor systems. Some provinces, such as Zhejiang, have issued regulations strictly prohibiting the use of high-strength chemical anchors on curtain walls, in which case only reverse-cone chemical anchors or capsule chemical anchors can be used instead. This article details the installation steps, adhesive consumption reference, and specification table for reverse-cone chemical anchors.
1. Understanding reverse-cone chemical anchors
1.1 What is a reverse-cone chemical anchor
The tail of the threaded rod of a reverse-cone chemical anchor adopts areverse-cone design, generally used with injection anchoring adhesive. Its load-bearing principle isthe combined action of chemical bonding and mechanical interlock — the adhesive provides bond strength, while the reverse cone forms a mechanical interlock with the concrete. Once the adhesive cures, an anchoring effect similar to mechanical locking is produced, making the anchorage more reliable.
1.2 The relationship between reverse-cone chemical anchors and capsule chemical anchors
Reverse-cone chemical anchors and capsule chemical anchorsdiffer only slightly and can generally be used interchangeably. Both are adhesive anchoring products that can be used with injection anchoring adhesive in cracked concrete. The same-size models perform almost identically in mechanical performance, and their prices are nearly the same.
Note that reverse-cone anchors in M8 are generally hard to find on the market; if an M8 chemical anchor is needed, a high-strength chemical anchor is usually the only option.
2. Installing reverse-cone chemical anchors
The installation steps for reverse-cone chemical anchors are as follows:
Step 1: Drilling — drill a hole of the specified diameter and depth according to the product instructions
Step 2: Blowing out dust — use a blow-out pump to blow the hole at least twice
Step 3: Brushing — use a brush to clean dust from the hole wall at least twice
Step 4: Blowing again — blow the hole again with the blow-out pump until no dust comes out of it
Step 5: Injecting adhesive — inject the modified epoxy anchoring adhesive
Step 6: Screwing in the anchor — simply screw in the reverse-cone chemical anchor
Steps (2), (3), and (4) serve toremove the dust adhering inside the hole and on the hole wall, preventing hazards caused by reduced or lost mechanical performance of the chemical adhesive.
3. Installation points in detail
3.1 Drilling points
When drilling, it is best to use a bit matched to the anchor — choose a model designed for drilling concrete. During drilling you mustavoid rebar, both to protect the main reinforcement and to protect the bit. Use an electric drill as the drilling tool, and drill precisely to the required diameter and depth. Before construction, mark the anchor positions accurately based on the design drawings and the base material conditions on site. Select a suitable rotary hammer or percussion drill, keep the bit perpendicular to the base material surface, and drill at a steady speed to prevent slanted holes that would cause uneven loading on the anchor.
3.2 Hole-cleaning points
Hole cleaning isthe most error-pronestep in reverse-cone chemical anchor installation. Strictly repeat the cycle of “blow out dust — brush — blow out dust” until no dust comes out of the hole. If cleaning falls short of the requirement, the bond between the adhesive and the concrete hole wall will be greatly compromised, and the anchorage cannot be guaranteed. We recommend the “three brushes and three blows” approach — blow, brush, blow again, brush again, then a third blow — to ensure the hole wall is clean.
3.3 Adhesive injection points
Injecting the anchoring adhesive requires adedicated adhesive gun, and installers must trial the adhesive on site to dose it correctly without waste. When injecting, note the following:
Adhesive consumption: approximately1/2—2/3
Purging the first beads: the first beads of anchoring adhesive have no bond; extrude them until the mixed color turns uniform
Injection method: start injecting steadily from the bottom of the hole, ensuring the adhesive fills gradually from the hole bottom toward the opening
Adhesive quantity control: fill to about two-thirds of the hole depth; a small amount of adhesive should overflow when the anchor is screwed in, ensuring a full adhesive layer
3.4 Setting the anchor
After injecting, immediately press the threaded rod into the hole with arotary pressing motion down to the bottom of the holerather than hammering it in, to ensure the adhesive is evenly distributed. Keep the anchor vertical as it is set, slowly pushing it in a single direction to the designed depth. Use a powered torque tool gripping the installation head to screw the anchor into the hole.
3.5 Curing and waiting
The injection anchoring adhesive used with reverse-cone chemical anchors has arelatively long curing time; allow sufficient curing time in the construction schedule:
| Base material temperature (℃) | Initial set time (min) | Full cure time (d) |
|---|---|---|
| -10 — -5 | 180 | 7 |
| -5 — 0 | 120 | 5 |
| 0 — 10 | 60 | 3 |
| 10 — 25 | 40 | 2 |
| 25 — 40 | 20 | 1 |
| ≥40 | 10 | 0.5 |
When the temperature falls below-10℃, the anchoring adhesive will not cure. At lower air temperatures curing takes even longer, so plan the construction schedule in advance.
The difference between initial set time and full cure time:Initial set time is when the adhesive begins turning from liquid to solid and the anchor is initially fixed. After initial set, the anchor can carry light loads (such as self-weight and wind loads), butmust not carry design loads. Full cure time is the time required for the adhesive to reach its final design strength; only after that may the anchor carry the full design load. Strictly distinguish these two stages on site, and apply loads only after full cure.
4. Reverse-cone chemical anchor specification table
The common national-standard sizes for reverse-cone chemical anchors are as follows:
| Model | Threaded rod diameter (mm) | Threaded rod overall length (mm) |
|---|---|---|
| M8×110 | 8 | 110 |
| M10×130 | 10 | 130 |
| M12×160 | 12 | 160 |
| M16×190 | 16 | 190 |
| M20×260 | 20 | 260 |
| M24×300 | 24 | 300 |
| M30×380 | 30 | 380 |
Daring also offerscustom non-standard productionservice; the company once supplied chemical anchors as large asM56×1500for a nuclear power project. For non-standard sizes such as M14 or M27, you can also consult Daring for custom solutions.
5. Adhesive consumption reference for reverse-cone chemical anchors
The reference adhesive consumption values for reverse-cone chemical anchors are as follows (based on one 390ml cartridge of anchoring adhesive):
| Reverse-cone anchor model | Hole diameter (mm) | Embedment depth (mm) | Holes per cartridge (390ml) |
|---|---|---|---|
| M12×160 | 14 | 110 | 28 |
| M16×190 | 18 | 125 | 15 |
| M20×260 | 25 | 170 | 6 |
| M24×300 | 28 | 210 | 4 |
| M30×380 | 35 | 280 | 2 |
6. Materials and surface treatments for reverse-cone chemical anchors
Daring reverse-cone chemical anchors are available incarbon steel of grade 5.8 or higheror304/316 stainless steel. Surface treatments for the carbon steel version (stainless steel excluded) include:electro-galvanizing、hot-dip galvanizingas options.
The reverse-cone chemical anchor is paired with Daring'sDL-200E modified epoxy injection anchoring adhesive, which meets the national Class A adhesive standard, delivering strong bond anchorage, temperature and seismic resistance, and suitability for cracked concrete. Once the adhesive cures, the anchor produces an anchoring effect similar to mechanical locking.
7. Scope of application and code requirements
Reverse-cone chemical anchors are mostly used for anchoring between concrete and the anchored elements inhigh-end projects, with main applications in important works such as rail transit and utility corridor systems.
In cracked concrete areas, structural elements can only be anchored using a combination of reverse-cone anchors and undercut mechanical anchors.Ordinary chemical anchors cannot be used on cracked concrete.
Some provinces, such as Zhejiang, have issued relevant regulations:Post-installed inserts for building curtain walls must, in accordance with design requirements, use reliable anchors such as post-cut (undercut) mechanical anchors and capsule chemical anchors; ordinary chemical anchors must not be used. When capsule chemical anchors are used, the supplier must provide a high-temperature test report for the chemical anchors. Over time, more and more provinces may introduce similar policies.
8. Frequently asked questions
| Q1 | What is the difference between reverse-cone chemical anchors and high-strength chemical anchors? High-strength chemical anchors are used with adhesive capsule cartridges, while reverse-cone chemical anchors are used with injection anchoring adhesive. Reverse-cone chemical anchors are suitable for cracked concrete, whereas high-strength chemical anchors are not. At large sizes, the ultimate tension of a reverse-cone chemical anchor can be about 20% higher than that of a high-strength chemical anchor. |
| Q2 | Can reverse-cone chemical anchors and capsule chemical anchors be used interchangeably? Yes. The two differ only slightly and can generally be used interchangeably. The same-size models perform almost identically in mechanical performance. Note, however, that reverse-cone anchors cannot be used with adhesive capsule cartridges, whereas capsule anchors can. |
| Q3 | How long does a reverse-cone chemical anchor take to cure? Reverse-cone chemical anchors use injection anchoring adhesive, which takes longer to cure. At 25℃-40℃, full cure takes about 2 days; at 10℃-25℃, about 4 days; below -10℃, the adhesive cannot cure. Plan the schedule in advance; after initial set the anchor can carry light loads, and only after full cure can it carry the full design load. |
| Q4 | Can a reverse-cone chemical anchor be installed with adhesive capsule cartridges? No. Reverse-cone chemical anchors must be used with injection anchoring adhesive. The adhesive quantity in a capsule cartridge is insufficient for a reverse-cone anchor, and the mechanical performance cannot be guaranteed. |
| Q5 | What reverse-cone chemical anchor products does Daring offer? The Daring chemical anchor range covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors. The special reverse-cone chemical anchors are made of carbon steel of grade 5.8 or higher or 304/316 stainless steel, paired with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Class A adhesive standard. For reverse-cone chemical anchor selection advice on a specific project, please contact the Daring technical team. |
The Daring chemical anchor range covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Class A adhesive standard, with carbon steel of grade 5.8 or higher or 304/316 stainless steel as options. The special reverse-cone chemical anchors deliver strong bond anchorage, temperature and seismic resistance, and suitability for cracked concrete, with stable anchorage under static and dynamic loads. They are widely used in various post-installed anchoring scenarios between concrete and exterior wall structural elements. For reverse-cone chemical anchor selection advice on a specific project, please contact the Daring technical team.
References
1. Daring website — difference between high-strength chemical anchors and reverse-cone chemical anchors(definition and comparison of reverse-cone chemical anchors)
2. Daring website — classification and uses of chemical anchors(chemical anchor classification and selection)
3. JGJ 145-2013, Technical Specification for Post-Installed Anchoring in Concrete Structures(national industry standard)
4. Daring website — what are the chemical anchor specifications and models(chemical anchor specification table)
5. Industry-standard data on reverse-cone chemical anchor installation procedures and adhesive consumption (installation key points and adhesive consumption reference)