Product Knowledge

Edge distance too small for expansion anchors? Undercut anchors generate no expansion stress and stay safe at small edge distances

Views: 0Posted on: 2026-09-07

First, the conclusion:The claim that expansion anchors cannot be used when the edge distance is too smallis completely correct. Expansion anchors generate friction by radially expanding against the borehole wall; when the edge distance is insufficient, the squeezing force at the hole mouth is greatest, which very easily causes the concrete tosplit and spall at the edges, and the specifications explicitly prohibit their use with insufficient edge distance. However,undercut anchors are an exception— they form amechanical lock, transferring all loads to the dense, deep concrete at the bottom of the hole,with no expansion stress on the borehole wall or at the hole mouth. Standard undercut anchors can be used normally with a minimum edge distance of≥3dor greater, whereas expansion anchors typically require ≥ 8d–10d. Daring undercut anchors use adeep mechanical lock at the bottom of the holedesign with no shallow expansion stress, and have passed Class S anchor certification and seismic tests, so construction with small edge distances remains safe and reliable.

In post-installed anchoring work in buildings, insufficient edge distance is themost common and troublesomeproblem on construction sites. At locations such as the edges of beams and columns, the ends of cantilever slabs and curtain wall terminations, the limited size of the members often makes it difficult for hole positions to meet the minimum edge distance required by the specifications. The traditional approach requires discarding expansion anchors and ordinary chemical anchors and re-drilling, resulting in wasted man-hours and schedule delays. This paper systematically answers the question of whether anchors can be used with too-small edge distances from the perspectives of specification requirements, load-bearing principles and the advantages of undercut anchors.

I. Why Are Expansion Anchors Sensitive to Insufficient Edge Distance?

1.1 Load-bearing principle of expansion anchors

Expansion anchors rely on the expansion element of the anchor producingfrictionagainst the borehole wall for anchoring. When the nut is tightened, the expansion body (sleeve or expansion segment) is compressed tightly against the borehole wall, generating pull-out resistance through the coefficient of friction between concrete and metal. The core prerequisite of this load-bearing mechanism is that the borehole wall all around must bedense, solid material, capable of withstanding the radial expansion pressure of the sleeve.

The expansion stress of an expansion anchoris concentrated in the area near the hole mouth, where the squeezing force is greatest. When the anchor is too close to the edge of the member, the external restraint is weak and the squeezing force concentrates in the shallow surface layer at the hole mouth, very easily causing the concrete tosplit, spall and chip at the edges。

1.2 Strict specification requirements for the edge distance of expansion anchors

According to JGJ 145-2013, 'Technical Specification for Post-installed Anchoring of Concrete Structures,' the minimum spacing s and minimum edge distance c of anchor groups should be determined on the basis of the anchor product'scertification report. When no certification report is available, the minimum spacing s of expansion anchors (torque-controlled type) is6dand the minimum edge distance c is8d. Taking an M12 anchor as an example, the minimum edge distance required reaches96mm。

When an anchor is loaded, a concrete tensile failure cone forms within the base material to carry the load, and the specifications require sufficient edge distance to be left. Insufficient edge distance leads to an incomplete failure cone and a substantial reduction in load-bearing capacity. At the same time, the minimum edge distance c of the anchor should not be less thantwice the maximum aggregate particle size。

1.3 Serious consequences of insufficient edge distance

With insufficient edge distance, expansion anchors face the following serious consequences:

  • Greatest squeezing force at the hole mouth: with insufficient edge distance, tightening the nut or bearing tension will cause micro-cracks, inevitably leading to edge spalling and loosening at a later stage

  • Sharp drop in load-bearing capacity: with insufficient edge distance, the concrete tensile failure cone is incomplete and the load-bearing capacity drops significantly

  • Explicitly prohibited by the specifications: expansion anchors offer no possibility of remedy when the edge distance is insufficient, and their use is explicitly prohibited by the specifications

II. Why Are Undercut Anchors Not Sensitive to Insufficient Edge Distance?

2.1 Load-bearing principle of undercut anchors — mechanical locking

Undercut anchors, also known as form-undercut anchors or post-cut anchors, are anchors for which, after a straight hole is drilled in the concrete base material, the bottom of the hole isreamed again, and the reamed cavity and the expanded keys of the anchor form amutually locking mechanism, achieving a post-installed anchoring connection. Its load-bearing mode ismechanical locking, and the anchoring principle is similar to the stress distribution effect of cast-in foundation bolts.

Undercut anchors form areverse-tapered cavityat the bottom of the borehole through secondary reaming; after the expansion segments at the anchor's base open, they form arigid mechanical lockwith the deep concrete, so that all loads are concentrated and transferred to the dense, deep concrete at the bottom of the hole, therebyavoiding the weak area at the edge of the member. Undercut anchors lock only in the reamed zone at the bottom of the hole, and during installation and loadingthere is no radial expansion pressure on the upper part of the borehole wall or at the hole mouth, so the concrete at the edge is not subjected to tension or compression.

2.2 No expansion stress — the core advantage for construction with small edge distances

Thecore advantage of undercut anchors is the absence of expansion stress. Expansion anchors resist pull-out through the friction between the expansion sleeve and the borehole wall; once the base material cracks or is subjected to vibration, the friction drops significantly. Undercut anchors are completely different — by pre-reaming at the bottom of the hole, the keys at the anchor's base open and form amechanical interlockwith the reamed cavity, and the load-bearing mode is similar to that of cast-in foundation bolts. This locking structuredoes not rely on friction, so it maintains stable anchoring force even if the base material cracks.

The lock of an undercut anchor produces no expansion stress, ensuring as far as possibleinstallation and fixing with small edge distances and small spacings. With no expansion stress, the initial stress applied to the concrete base material is small, making it particularly suitable forconfined spaces, small edge distances and small spacingsinstallation scenarios.

2.3 Small-edge-distance capability of undercut anchors

Standard undercut anchors can be used normally with a minimum edge distance of≥3dor greater. This means:

  • M8 undercut anchor: minimum edge distance ≥ 24 mm

  • M12 undercut anchor: minimum edge distance ≥ 36 mm

  • M16 undercut anchor: minimum edge distance ≥ 48 mm

whereas expansion anchors typically require a minimum edge distance of ≥ 8d–10d. Taking the M12 as an example, an expansion anchor requires an edge distance ≥ 96 mm, while an undercut anchor needs only ≥ 36 mm —the edge distance requirement of undercut anchors is only about one-third that of expansion anchors。

Some properly certified products can accommodatesmaller edge distances, making them suitable for scenarios such as misaligned existing holes, limited member dimensions and narrow-edge fixing. After verification and load reduction by a design institute, such scenarios can be used for static load-bearing, steel structure fixing and curtain wall bracket applications.

III. Normative Basis

3.1 The normative status of undercut anchors

According toGB 50367-2013, 'Code for Design of Strengthening Concrete Structure', Clause 16.1.3, mechanical anchors used in load-bearing structures should beundercut anchors with a locking effect. When anchors are used in load-bearing structures in seismic fortification zones, undercut anchors or special reverse-cone adhesive anchors should be used.

Daring undercut anchors are made of grade 5.8 or higher carbon steel or 304/316 stainless steel, and the products comply withJGJ 145-2013the requirements of the specifications.

3.2 Edge distance detailing requirements

According to Clause 16.4.4 of GB 50367-2013, the minimum edge distance c of undercut anchors is0.8hefand the minimum spacing s is1.0hef(hef is the effective embedment depth). According to Clause 7.1.2 of JGJ 145-2013, the minimum edge distance c of undercut anchors is6dand the minimum spacing s is6d(d is the outer diameter of the anchor).

The minimum edge distance c of the anchor should also not be less thantwice the maximum aggregate particle size. The minimum edge distance and minimum spacing that do not cause splitting failure during anchor installation should be determined from the anchor product'scertification report.

3.3 Verification requirements for insufficient edge distance

Undercut anchors rely purely on mechanical interlocking and do not depend on adhesive bonding, so the load-bearing capacity isstable and controllable. Under small-edge-distance conditions, load-bearing capacity reduction verification can be carried out throughstructural calculation, and if the verification meets the requirement, the anchor can be used in compliance and pass pull-out acceptance.

Small-edge-distance hole positions that can be successfully remedied must follow a standardized procedure, and the concrete around the holemust be dense, free of cracks, free of voids and free of chipped cornersis a prerequisite. The matter must be reported to a technician or design institute for evaluation and confirmation.

IV. Expansion Anchors vs. Undercut Anchors — Comparison of Edge Distance Requirements

Comparison dimensionExpansion anchorUndercut anchor
Load-bearing principleFriction-based (expansion pressing against the borehole wall)Mechanical locking (interlock in the reamed hole)
Edge distance requirement8d-10d≥3d
M12 minimum edge distance≥96mm≥36mm
Base material stressExpansion stress present, likely to cause cracking of the base materialNo expansion stress, gentle on the base material
Suitability for cracked concreteNot applicableApplicable
Suitability for load-bearing structuresStrictly prohibitedMandatorily required

V. Selection Decision Guide

5.1 Anchor selection recommendations for insufficient edge distance

Working conditionRecommended solutionRemarks
Edge distance ≥ 8dEither expansion anchors or undercut anchorsmeets the specification requirements
3d ≤ edge distance < 8dUndercut anchorExpansion anchors cannot be used; undercut anchors have no expansion stress
Edge distance < 3dRequires design verification or an adjusted solutionMay be used only after load-bearing capacity reduction verification passes
Concrete already cracked, spalled or containing voidsNo anchor may be usedThe base material itself is defective; it must be discarded and re-drilled

5.2 Situations where undercut anchors are preferred

  • Limited edge distance: locations with limited member dimensions, such as beam and column edges, cantilever slab ends and curtain wall terminations

  • Load-bearing structures: specifications mandate the use of undercut anchors in load-bearing structures

  • Cracked concrete: undercut anchors are suitable for cracked concrete

  • Seismic fortification zones: undercut anchors have excellent seismic performance, and their load-bearing capacity is essentially unaffected by dynamic loads

  • Narrow-edge fixing: when member width is limited, undercut anchors are the best choice

5.3 Situations where undercut anchors should not be forced

  • Concrete already cracked, with chipped corners, or loose and damaged: the base material itself is defective and cannot be remedied

  • Thin plaster or voids in the surface layer: the member itself has quality problems

  • Old, loose concrete with severe carbonation: the deep base material no longer provides anchoring conditions

  • Critical load-bearing joints subject to high seismic demand, high fatigue or frequent dynamic loads: the use of extremely small edge distances is strictly prohibited

VI. Daring Undercut Anchor Solutions for Small Edge Distances

6.1 Core product advantages

Daring undercut anchors use adeep mechanical lock at the bottom of the holedesign; secondary reaming forms a reverse-tapered cavity at the bottom of the borehole, and after the expansion segments at the anchor's base open, they form a rigid mechanical lock with the deep concrete, concentrating and transferring all loads to the dense, deep concrete at the bottom of the hole,no shallow expansion stress:

  • Small-edge-distance construction: standard undercut anchors can be used normally with a minimum edge distance ≥ 3d

  • No expansion stress: the initial stress applied to the concrete base material is small and will not cause cracking

  • High load-bearing capacity: typical M12 load-bearing capacity ≥ 60 kN, more than twice that of expansion anchors

  • Excellent seismic performance: load-bearing capacity is essentially unaffected by dynamic loads, with no risk of slip

  • Multiple certifications: Class S anchor certification, 2-million-cycle fatigue resistance, 120-minute fire resistance and seismic testing

6.2 Product range

The Daring undercut anchor range covers sizes M8–M20:

  • M8×40×80— suitable for thin panels and small-load applications

  • M10×60×100— for standard curtain walls and light-load fixing

  • M12×80×130— the most widely used model, well balanced in all respects

  • M12×100×150— greater embedment depth and higher load-bearing capacity

  • M16×100×160 / M16×125×190— for high-load applications

  • M20×160×260— for very high loads and heavy equipment

Materials include grade 5.8 and grade 8.8 carbon steel (hot-dip galvanized coating ≥ 45 μm) and 304/316 stainless steel, withoriginal manufacturer reaming bits and power installation toolsprovided to ensure reaming quality.

VII. Frequently Asked Questions

Q1Is it true that expansion anchors cannot be used when the edge distance is too small?
Yes. Expansion anchors generate friction by radially expanding against the borehole wall; when the edge distance is insufficient, the squeezing force at the hole mouth is greatest, very easily causing the concrete to split and spall at the edges. The specifications explicitly prohibit the use of expansion anchors with insufficient edge distance.
Q2What is the minimum edge distance for undercut anchors?
Standard undercut anchors can be used normally with a minimum edge distance ≥ 3d. Taking the M12 as an example, the minimum edge distance is ≥ 36 mm, whereas expansion anchors typically require ≥ 8d–10d (96–120 mm). Some properly certified products can accommodate smaller edge distances.
Q3Why do undercut anchors have no expansion stress?
Undercut anchors form a reverse-tapered cavity at the bottom of the borehole through secondary reaming; after the expansion segments at the anchor's base open, they form a rigid mechanical lock with the deep concrete, and all loads are transferred to the dense, deep concrete at the bottom of the hole. There is no radial expansion pressure on the upper part of the borehole wall or at the hole mouth.
Q4Do undercut anchors require verification when the edge distance is insufficient?
Yes. Undercut anchors rely purely on mechanical interlocking, and their load-bearing capacity is stable and controllable. Under small-edge-distance conditions, load-bearing capacity reduction verification can be carried out through structural calculation; if the verification meets the requirement, the anchor can be used in compliance and pass pull-out acceptance. Evaluation and confirmation by a technician or design institute are required.
Q5Are Daring undercut anchors suitable for construction with small edge distances?
Yes. Daring undercut anchors use a deep mechanical lock design at the bottom of the hole with no shallow expansion stress, and can be used normally with a minimum edge distance ≥ 3d. The products have passed multiple tests, including Class S anchor certification, 2-million-cycle fatigue resistance, 120-minute fire resistance and seismic testing, and are suitable for cracked and uncracked concrete.

The Daring undercut anchor range covers sizes M8–M20, with materials including grade 5.8 and grade 8.8 carbon steel (hot-dip galvanized coating ≥ 45 μm) and 304/316 stainless steel; mechanical locking achievesimmediate locking upon installation with no curing required, high load-bearing capacity, seismic and fatigue resistance, and suitability for multiple base materials such as cracked/uncracked concrete and natural stone. Standard undercut anchors can be used normally with a minimum edge distance of≥3dor greater, making them thepreferred solutionfor small-edge-distance construction with no expansion stress. For undercut anchor selection and construction recommendations for small edge distances in specific projects, please consult the Daring technical team.

References

Daring official website — undercut mechanical anchor product page

Daring official website — differences between expansion anchors and undercut anchors

Daring official website — detailed classification of mechanical anchors

JGJ 145-2013, 'Technical Specification for Post-installed Anchoring of Concrete Structures'

GB 50367-2013, 'Code for Design of Strengthening Concrete Structure'

GB 50011, 'Code for Seismic Design of Buildings'

Back to Daring Home  Back to Top