First, the conclusion:Verification of the load-bearing capacity of cast-in channels mainly relies onfield pull-out tests, with the core acceptance criteria being:displacement under the design load ≤ 0.5 mm,no plastic deformation or slip under 1.5 times the design load,failure load ≥ 3 times the design loadand no loss of anchoring. Field pull-out tests strictly comply withJGJ 145-2013andTB/T 3329-2013the appendix specifications. The test uses continuous staged loading, applying the design load, 1.5 times the design load and the failure load in sequence, with the loading rate controlled at0.15-0.5kN/sbetween the specified values. The static load-bearing capacity of cast-in channels is required to meetno deformation at 1.5 times the design load and no failure at 3 times the design load, and the fatigue testpasses 2 million cycles. Acceptance sampling is carried out by batch (e.g., every 2,000 m as one batch), with random selection of5 complete channel samplesand20 sets of T-head boltsfor testing. Daring cast-in channels strictly comply with the above standards and have passed multiple tests, including 2-million-cycle fatigue resistance and fire resistance, ensuring that the load-bearing capacity meets project requirements.
In tunnels, utility corridors, building curtain walls and other projects, cast-in channels are the foundational components that carry critical facilities such as the catenary, pipelines and equipment. Whether the load-bearing capacity of cast-in channels meets the standard directly affects the structural safety and long-term operational stability of a project. Many engineers lack a systematic understanding of how to verify the load-bearing capacity of cast-in channels, how to perform field pull-out tests and what the acceptance criteria are. This paper provides a comprehensive analysis from the perspectives of normative basis, test methods, acceptance criteria and inspection procedures.
I. Normative Basis for Verifying the Load-Bearing Capacity of Cast-in Channels
1.1 Core standards and specifications
The design, inspection and acceptance of the load-bearing capacity of cast-in channels are mainly based on the following specifications:
TB/T 3329-2013'Cast-in Channels in Tunnels for Electrified Railway Catenaries' — specifies the terms and definitions, classification, technical requirements, inspection methods and inspection rules for cast-in channels. Load-bearing capacity testing mainly includesthe static load-bearing capacity test of T-head bolts and the static load-bearing test of the channeltwo aspects.
JGJ 145-2013'Technical Specification for Post-installed Anchoring of Concrete Structures' — the field pull-out test method is performed in strict accordance with this standard.
JG/T 560-2019'Channel-shaped Cast-in Components for Buildings' — specifies the test methods for the tensile load-bearing capacity of components, the tensile load-bearing capacity of T-head bolt assemblies and the anchoring load-bearing capacity.
T/CAMET 02002-2019'Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit' — applies to the design selection and product inspection of cast-in channels and sleeves in urban rail transit projects.
GB/T 37613-2019'Cast-in Channel Sections' — the national standard for cast-in channel sections.
1.2 Overview of acceptance criteria
According to TB/T 3329-2013 and related specifications, the core acceptance indicators for cast-in channels include:
Appearance: no surface defects; the channel and anchor rods should be free of cracks, folds, delamination and other defects
Dimensional tolerance: all geometric dimensions should be within the allowable deviation range
Anti-corrosion coating: galvanized coating thickness ≥ 80 μm, meeting the 1,200-hour salt spray test requirement
Static load-bearing capacity: no deformation at 1.5 times the design load and no failure at 3 times the design load
Fatigue performance: qualified in the 2-million-cycle fatigue test
Construction and installation: axis deviation ≤ 5 mm, elevation error ± 3 mm, levelness deviation ≤ 2‰
II. Field Pull-Out Test Method
2.1 Test principle
The pull-out test is thecore inspection methodfor evaluating the anchoring performance of cast-in channels. By applying a gradually increasing pull-out load to a channel or anchor embedded in concrete, it verifies whether the anchoring connection can withstand the design load without pull-out failure. The pull-out test can determine the channel'smaximum load-bearing capacity and deformation。
2.2 Test equipment and preparation
The field pull-out test requires the following equipment and preparations:
Pull-out tester: a high-precision portable pull-out tester, suitable for confined spaces such as tunnels and utility corridors
Reaction frame: ensure that the fixed reaction frame is coaxial with the channel
Displacement sensor: real-time monitoring of the load–displacement curve
Preparation stage: verify design parameters, calibrate the pull-out tester, clean debris from the channel and match the special fixture
Zhonggang Guojian is equipped with100 kN to 2,000 kNpull-out equipment of different ranges, which can meet the inspection needs of channels of different specifications. The inspection strictly followsJGJ 145-2013、TB/T 3329-2013standards and is compatible with both field and laboratory modes.
2.3 Loading procedure
The field pull-out test usescontinuous staged loading, with the specific procedure as follows:
Loading rate: uniform loading, with the rate controlled at0.15-0.5kN/swithin
Design load stage: apply the design load and record load, displacement and deformation
1.5-times-design-load stage: load to 1.5 times the design load and hold for10 seconds, and observe whether plastic deformation occurs
Failure load stage: continue loading until the channel fails, so as to determine the ultimate load
The test process can be subdivided intopreloading, staged loading to the design value, sustained load holding and final failure loadingfour stages, with the displacement–load curve collected in real time. Inspection items includeanchor rod slip, local deformation of the channel and ultimate pull-out forceetc.
2.4 Supplementary laboratory test methods
In addition to field pull-out tests, the load-bearing capacity of cast-in channels is also verified in the laboratory through the following methods:
Universal material testing machine: applies a uniform and steady load to the channel, with a loading speed not exceeding0.5kN/s
Embedded concrete specimen: the channel is embedded in a concrete specimen with a strength of not less thanC30 or C50concrete.
Bare-specimen test: the channel body is placed on a support platform and subjected to axial tension or compression
III. Acceptance Criteria
3.1 Acceptance criteria for static load-bearing capacity
According to TB/T 3329-2013 and related specifications, the acceptance criteria for the static load-bearing capacity of cast-in channels are as follows:
| Inspection item | Acceptance criterion |
|---|---|
| Displacement under design load | ≤0.5mm |
| 1.5 times design load | No plastic deformation, no slip |
| Failure load | ≥ 3 times design load, no loss of anchoring |
| Ultimate load-bearing capacity | ≥ 2.0 times the design value |
The static load-bearing test of the channel requires that under1.5 times the design load for 10 seconds, and observation is made for plastic deformation. Load-bearing capacity inspection mainly includessingle-anchor-column tensile load, shear working load, deflection test and double-anchor-column tensile loadetc. After the failure test, the channel should not show obvious plastic deformation or failure damage.
3.2 Acceptance criteria for fatigue performance
The fatigue performance of cast-in channels is a key indicator for ensuring long-term service safety:
Fatigue test: cast-in channels should pass the2-million-cycle fatigue testand be qualified
Dynamic fatigue test: at0.5 to 1.0 times the design loadsinusoidal cyclic loading is carried out
3.3 Acceptance criteria for construction and installation
After passing the field pull-out test, the following construction and installation acceptance criteria must also be met:
Embedment position: the channel is accurately positioned,axis deviation ≤ 5 mm
elevation error:±3mm
levelness deviation:≤2‰
Anchoring firmness: the pull-out test is qualified,no loosening, no slip
Grounding resistance: the grounding connection is reliable,≤1Ω
IV. Sampling Rules and Inspection Process
4.1 Sampling rules
Sampling for the load-bearing capacity inspection of cast-in channels should meet the following requirements:
Sampling unit: products from the same manufacturer, same material, same specification, same process and same batch constitute one sampling unit
Batch division: divided into batches as specified (e.g., every2000mas one batch)
Channel samples: randomly cut5 complete samples, with lengths meeting the test requirements (usually ≥ 500 mm)
T-head bolts: randomly select20 setscomplete matched bolt sets
Field sampling inspection: at arate of 1% and no fewer than 3 piecesfor sampling inspection
4.2 Field inspection process
The standard operating procedure for the field pull-out test is as follows:
Step 1: Cleaning— remove debris from the channel and ensure the inspection surface is clean
Step 2: Connection— connect the pull-out tester to the anchor rod and install the special fixture
Step 3: Pre-tightening— apply pre-tightening force to ensure the loading system is stable
Step 4: Loading— load uniformly at a rate of ≤ 0.5 kN/s
Step 5: Load holding— hold the load at 1.5 times the design load for 10 seconds
Step 6: Monitoring— simultaneously monitor load, displacement, cracks and slip
Step 7: Recording— record relevant data and phenomena
4.3 Conditions for type inspection
A type inspection should be carried out under any of the following conditions:
Finalization of a new productwhen
after formal production has begun,structure, material or processundergoes significant changes that may affect product performance
The manufacturerhas stopped production for more than one year andresumes production
incoming inspection results show asignificant differencefrom the previous type inspection
The manufacturer'sinitial supplyof the product
V. Load-Bearing Capacity Assurance of Daring Cast-in Channels
5.1 Product advantages
Daring cast-in channels are manufactured in strict accordance with TB/T 3329-2013, GB/T 38525-2020 and other standards, and have the following advantages:
Reliable materials: made of Q355 steel or 304/316 stainless steel, meeting the material requirements of the specifications
Diverse processes: offeringwelding and rivetingas two process options
Comprehensive testing: having passed2-million-cycle fatigue resistance, fire resistance and other tests
Load-bearing capacity assurance: meeting the requirements of no deformation at 1.5 times the design load and no failure at 3 times the design load
5.2 Inspection support
Daring cast-in channels can cooperate with third-party testing agencies to carry out field pull-out tests:
A third-party testing agency withCMA qualificationmay be commissioned to conduct field pull-out tests
Inspection items covertensile load-bearing capacity, shear load-bearing capacity and sliding load-bearing capacityetc.
The test report contains detailed parameters, load–displacement curves and conclusions
VI. Frequently Asked Questions
| Q1 | How is the load-bearing capacity of cast-in channels verified? It is verified mainly through field pull-out tests. The test uses continuous staged loading, and displacement, deformation and ultimate load-bearing capacity are inspected under the design load, 1.5 times the design load and the failure load, respectively. The acceptance criteria are: displacement under the design load ≤ 0.5 mm, no plastic deformation under 1.5 times the design load, and failure load ≥ 3 times the design load. |
| Q2 | What are the acceptance criteria for the pull-out test of cast-in channels? Three requirements: displacement under the design load ≤ 0.5 mm; no plastic deformation or slip under 1.5 times the design load; failure load ≥ 3 times the design load with no loss of anchoring. The static load-bearing capacity must also meet the requirements of no deformation at 1.5 times the design load and no failure at 3 times the design load, and the fatigue test must pass 2 million cycles. |
| Q3 | Which specifications govern the field pull-out test of cast-in channels? It is performed mainly in accordance with JGJ 145-2013, 'Technical Specification for Post-installed Anchoring of Concrete Structures,' and the appendix of TB/T 3329-2013, 'Cast-in Channels in Tunnels for Electrified Railway Catenaries.' Load-bearing capacity inspection focuses on two aspects: the static load-bearing capacity of T-head bolts and the static load-bearing capacity of the channel. |
| Q4 | How is sampling carried out for the load-bearing capacity inspection of cast-in channels? Products from the same manufacturer, same material, same specification, same process and same batch constitute one sampling unit (e.g., every 2,000 m as one batch). Five complete channel samples are randomly cut, and 20 sets of T-head bolts are randomly selected. Field sampling inspection is carried out at a rate of 1% and on no fewer than 3 pieces. |
| Q5 | Which load-bearing capacity requirements do Daring cast-in channels meet? Daring cast-in channels strictly comply with TB/T 3329-2013 and other standards, having passed multiple tests including 2-million-cycle fatigue resistance and fire resistance. They meet the requirements of no deformation at 1.5 times the design load and no failure at 3 times the design load, and a CMA-qualified third-party agency may be commissioned to conduct field pull-out tests for verification. |
Daring cast-in channels strictly comply with TB/T 3329-2013, GB/T 38525-2020 and other standards. They are made of Q355 steel or 304/316 stainless steel, with both welding and riveting processes available. The products have passed multiple tests including 2-million-cycle fatigue resistance and fire resistance, and the matching T-head bolts allow flexible three-dimensional adjustment. For load-bearing capacity verification plans and field pull-out test recommendations for specific projects, please consult the Daring technical team.
References
Daring official website — welded cast-in channel product page
Daring official website — riveted cast-in channel product page
TB/T 3329-2013, 'Cast-in Channels in Tunnels for Electrified Railway Catenaries'
JGJ 145-2013, 'Technical Specification for Post-installed Anchoring of Concrete Structures'
JG/T 560-2019, 'Channel-shaped Cast-in Components for Buildings'
T/CAMET 02002-2019, 'Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit'