Product Knowledge

Chemical anchor installation in winter: how to guarantee anchoring force at low temperatures

Views: 0Posted on: 2026-09-08

First, the conclusion:For chemical anchor installation in low-temperature winter conditions, the core principle istemperature control. When the substrate temperature falls below-5℃, ordinary chemical anchor cartridges willwill not set, and the anchoring essentially fails. At low temperatures the curing time of chemical anchors is greatly extended — 1–3 hours at 0°C to 10°C and 5–12 hours at -5°C to 0°C. To ensure anchoring force, the following should be done in winter construction:select a low-temperature anchoring adhesive, preheat the adhesive and substrate before installation, thoroughly clean the hole and remove ice, and extend the curing period. If the schedule needs to be accelerated, switch toUndercut mechanical anchors— carrying load through pure mechanical interlock, locking immediately upon installation with no curing required, and completely unaffected by temperature. Daring high-strength chemical anchors are supplied with modified vinyl resin cartridges and can be installed at temperatures above -5°C; Daring undercut anchors have passed S-class anchor certification, 2 million fatigue cycles, 120-minute fire resistance, seismic testing and numerous other tests, making them a reliable choice for winter anchoring.

Low-temperature construction in winter is one of thethe most common challenge. In northern regions, autumn and winter temperatures are extremely low, with temperatures of more than ten degrees below zero or even thirty degrees below zero being common. The curing reaction of chemical anchor resin virtually stalls at low temperatures, leaving construction crews facing a dilemma: stop work and wait, or proceed at risk and leave safety hazards. Starting from the mechanism by which low temperatures affect chemical anchors, this article systematically explains the precautions for winter chemical anchor installation and the key measures to ensure anchoring force.

I. The effect of low temperatures on chemical anchors

1.1 How low temperatures affect the anchoring force of chemical anchors

The anchoring force of a chemical anchor comes from thebond strength. Curing is essentially a chemical reaction, and temperature directly affects the reaction rate. In low-temperature environments, chemical anchors face the following problems:

  • dramatically reduced curing speed: resin that cures in 30 minutes to 1 hour at room temperature takes 1–3 hours at 0°C to 10°C and 5–12 hours at -5°C to 0°C

  • increased resin viscosity: at low temperatures the anchoring agent becomes viscous, making it difficult to fill the borehole evenly during injection and easily creating voids or bubbles that reduce anchoring force

  • Incomplete curing: at excessively low temperatures the resin cannot fully cure, and the bond strength is far below the design value

  • Cannot set below -5°C: ordinary chemical anchor cartridges will not set below -5°C and the anchoring essentially fails

1.2 Curing time reference at different temperatures

Substrate temperatureCuring time (reference)Installation recommendation
<-5℃Cannot setSwitch to undercut anchors or special ultra-low-temperature adhesive
-5℃~0℃5–12 hoursSelect a low-temperature resin and provide adequate insulation
0℃~10℃1–3 hoursInstallable, with appropriately extended curing
10℃~20℃30–90 minutesStandard installation procedure
>20℃20–30 minutesRapid curing with the highest efficiency

Near the critical temperature, injection anchoring adhesive may take as long as6–8 days, seriously affecting the construction schedule.

II. Key precautions for winter chemical anchor installation

2.1 Select a low-temperature anchoring adhesive

Ordinary chemical anchors cannot be installed below -5°C; selecta low-temperature anchoring adhesive. Some modified vinyl resin products can be installed at-5℃~-10℃Daring high-strength chemical anchors are supplied with modified vinyl resin cartridges,installable at temperatures above -5°C, setting rapidly in 30 minutes (at room temperature).

When selecting a low-temperature anchoring adhesive, note the following:

  • Check theminimum installation temperatureandcuring schedule

  • in the product data sheet, and ensure the adhesive is still within itseffective shelf life, and expired adhesive must never be used

  • Low-temperature anchoring adhesives vary considerably between brands; selectproducts that have passed authoritative testing.

2.2 Preheat the adhesive and substrate before installation

In low-temperature environments, an adhesive that is too cold will become more viscous and difficult to inject. Before installation, the adhesive should undergopreheating:

  • Adhesive preheating: place the anchoring agent inwarm water at 40°C for about 15 minutesso that the adhesive warms up evenly

  • Substrate preheating: locally heat thesubstrate (25–30°C), which can shorten curing time by about 50%

  • Remove ice from the hole: heat and clear ice, frost, snow and moisture from the hole, keeping it dry

  • Adhesive insulation: before installation, keep the adhesive indoors or in an insulated box to warm it up and improve curing efficiency

2.3 Thoroughly clean the hole and keep it dry

During winter construction, the hole may retainfrost, snow or condensed water, and this moisture seriously affects the bonding performance of the anchoring adhesive. The hole-cleaning steps must be strictly followed:

  • Blow out dust: use a dust blower or compressed air to blow out the hole at least twice

  • Brush the hole: use a dedicated brush to clean dust from the borehole wall at least twice

  • Remove ice and frost: if ice or frost is present in the hole, use a heat gun to heat and dry it

  • Second dust blowing: use the dust blower again on the hole until no dust comes out

2.4 Extend the curing period

The curing time of chemical anchors at low temperaturesmust be substantially extended. During installation, allow sufficient curing time based on the substrate temperature:

  • 0℃~10℃: extend the curing time to48–72 hours

  • -5℃~0℃: the curing time needs to bemore than 5–12 hours, and adequate insulation measures must be taken

  • No early disturbance is allowed: do not touch or apply any load during the gelation period

  • Provide adequate insulation coverage: after the anchors are installed, the work area can be covered with insulation to slow heat loss

2.5 Avoid installation in rain or snow

According toJGJ 145-2013, Technical Specification for Post-Installed Anchorage of Concrete Structures, the installation of chemical anchorsmust not be carried out outdoors in strong winds, rain or snow. Rain and snow in winter not only lower the substrate temperature but also cause water accumulated in the hole to freeze, seriously affecting anchoring quality. If winter installation is unavoidable, atemporary insulated sheltershould be erected to shield against wind and snow.

III. An alternative for winter anchoring — undercut mechanical anchors

3.1 Why undercut anchors are unaffected by temperature

Undercut mechanical anchors achievepure mechanical interlockfor anchoring — after a straight hole is drilled into the concrete substrate, the bottom of the hole isreamed again, and the reamed cavity forms an interlocking mechanism with the expanded segments of the anchor. The load is carried by mechanical interlock,without relying on any chemical adhesive, thereforecompletely unaffected by temperature。

Once an undercut anchor is installedit is ready for immediate use with no curing wait, and can carry load as soon as installation is complete. Whether the ambient temperature is 30°C or -40°C, the installation and load capacity of undercut anchors arecompletely unaffected。

3.2 Winter installation comparison: chemical anchors vs undercut anchors

Comparison dimensionChemical anchors (winter)Undercut anchors
Curing wait5 hours to 8 days (at low temperatures)Zero wait, ready for immediate use
Minimum installation temperature-5°C (ordinary types cannot set)No restriction
Installation stepsDrilling → hole cleaning → adhesive injection → rebar installation → curing waitDrilling → reaming → hole cleaning → installation
Temperature effectcannot set below -5°Ccompletely unaffected
Load capacitysignificantly reduced at low temperaturesconstant with no reduction

IV. Daring winter anchoring solutions

4.1 Daring high-strength chemical anchors — installable above -5°C

Daring high-strength chemical anchors are supplied withmodified vinyl resin cartridges, and atabove -5°Cthey can be installed and cured normally, with an operating temperature range covering-5℃~40℃. By optimizing the ratio of resin to curing agent, sufficient chemical reactivity is maintained even in low-temperature environments, with rapid setting in 30 minutes (at room temperature). The pull-out capacity of an M12 chemical anchor can reach60kN。

4.2 Daring undercut anchors — a tool for accelerating winter schedules

Daring undercut anchors are based onpure mechanical interlockat their core and have passedETA certification, S-class anchor certification, 2 million fatigue cycles, 120-minute fire resistance and seismic testingand numerous other tests:

  • locks immediately upon installation with no curing required: unaffected by temperature, ready for immediate use even in winter

  • High load capacity: typical M12 load capacity ≥43.8 kN, 2 to 3 times that of expansion anchors

  • No expansion stress: gentle on the concrete substrate and does not cause cracking

  • Suitable for cracked and uncracked concrete: for a wider range of applications

The Daring undercut anchor series coversM8-M20sizes, with materials including grade 5.8 and 8.8 carbon steel (hot-dip galvanized ≥45 μm) and 304/316 stainless steel, supplemented byoriginal-manufacturer undercutting drill bits and electric installation toolsto ensure construction quality. The products comply withJGJ 145-2013、GB 50367-2013and other standards.

V. Common questions about winter chemical anchor installation

Q1Can chemical anchors cure below 0°C?
Ordinary chemical anchors cannot set below -5°C. However, low-temperature anchoring adhesive can still cure normally at a substrate temperature of -5°C, although the curing time is greatly extended to 5–12 hours.
Q2What should be noted when installing chemical anchors in winter?
Key points: select a low-temperature anchoring adhesive, preheat the adhesive and substrate before installation, thoroughly clean the hole and remove ice and frost, extend the curing period, and erect an insulated shelter to avoid rain and snow.
Q3How long is the curing time for chemical anchors in winter?
At 0°C to 10°C, 1–3 hours are required; at -5°C to 0°C, 5–12 hours. Near the critical temperature, injection anchoring adhesive may take as long as 6–8 days to fully cure.
Q4Which anchors should be used to accelerate winter schedules?
Undercut mechanical anchors are recommended. They carry load through pure mechanical interlock, lock immediately upon installation with no curing required, and are completely unaffected by temperature. Daring undercut anchors have passed S-class anchor certification, 2 million fatigue cycles, seismic testing and numerous other tests.
Q5Can Daring chemical anchors be used in winter?
Yes. Daring high-strength chemical anchors are supplied with modified vinyl resin cartridges, can be installed at temperatures above -5°C, and set rapidly in 30 minutes (at room temperature). If installation is needed at lower temperatures or to accelerate the schedule, Daring undercut anchors can be selected.

The Daring chemical anchor series covers high-strength, capsule, special reverse-cone and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Class A adhesive standard, and available in grade 5.8 or higher carbon steel or 304/316 stainless steel. Daring high-strength chemical anchors are supplied with modified vinyl resin cartridges,and can be installed at temperatures above -5°C, setting rapidly in 30 minutes (at room temperature). If installation is needed at lower temperatures or to accelerate the schedule, Daring undercut anchorslock immediately upon installation with no curing required, are completely unaffected by temperature and are a reliable choice for winter anchoring. For advice on selecting a winter anchoring solution for a specific project, please consult the Daring technical team.

References

Daring website — undercut mechanical anchor product page

Daring website — curing time of chemical anchors

Daring website — how to install chemical anchors at low temperatures

Daring website — can chemical anchors cure below 0°C

JGJ 145-2013, Technical Specification for Post-Installed Anchorage of Concrete Structures — temperature requirements for winter installation of chemical anchors

GB 50367-2013, Code for Design of Strengthening Concrete Structures — post-installed anchorage design and construction requirements