The bottom line first:Chemical anchors are mainly divided into high-strength chemical anchors, reverse-cone chemical anchors, and capsule chemical anchors types. Among them, the high-strength chemical anchor (also called ordinary chemical anchor) is used with a chemical capsule and has the largest usage, but is only suitable for non-cracked concrete; reverse-cone and capsule chemical anchors are used with injection anchoring adhesive, differ only slightly and are generally interchangeable, and are suitable for both cracked and non-cracked concrete, mostly in major projects such as rail transit and utility tunnel systems.Curtain wall load-bearing structures must use special reverse-cone chemical anchors (capsule chemical anchors); ordinary chemical anchors are strictly prohibited.
Chemical anchors are among the most commonly used anchor products in post-installed anchoring work, and their usage may well exceed that of all other anchoring materials combined. Faced with the wide variety of chemical anchor products on the market, many designers and purchasers have only a partial understanding of the differences among "high-strength chemical anchors", "reverse-cone chemical anchors", and "capsule chemical anchors". This article systematically reviews the three types of chemical anchors in terms of appearance, adhesive, application scenarios, load capacity, and other dimensions.
1. Basic definition of chemical anchors
According to the definition in Annex A.1.4 of JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures, a chemical anchor is an anchor consisting of a metal threaded rod and an anchoring adhesive, which achieves anchoring through the anchoring adhesive. Based on rod form and anchoring mechanism, chemical anchors can be divided into ordinary chemical anchors and special reverse-cone chemical anchors types.
However, in actual engineering and market practice, chemical anchors are usually subdivided into high-strength chemical anchors, reverse-cone chemical anchors, and capsule chemical anchors three types. Among them, "capsule chemical anchor" and "special reverse-cone chemical anchor" refer to the same type of product under different names.
2. Detailed introduction to the three types of chemical anchors
2.1 High-strength chemical anchors (ordinary chemical anchors)
The high-strength chemical anchor is the most common type of chemical anchor, consisting of a metal threaded rod and a chemical agent sealed in a glass tube (vinyl resin adhesive). During installation, rotating the rod breaks the glass tube so the agent mixes and fills the space between the rod and the concrete hole wall, achieving anchoring through the bonding action of the adhesive.
Key features:
Matching adhesive: chemical capsule (glass tube) containing quartz sand, unsaturated resin, and curing agent
Rod form: ordinary fully threaded rod with a cutting-tip style bottom
Suitable concrete: only suitable for non-cracked concrete, not suitable for cracked concrete
Market share: very large usage, accounting for more than 50%
Curing time: relatively fast; at an outdoor temperature of 40°C it fully cures in about 20-30 minutes
Price: relatively low
Curtain wall load-bearing:Strictly prohibited
High-strength chemical anchors are mostly used for anchoring curtain wall structural components and can also be used for fixing mechanical equipment. Note, however, that some regions, such as Zhejiang, have prohibited the use of high-strength chemical anchors in curtain wall projects in their codes.
2.2 Reverse-cone chemical anchors
The tail of the reverse-cone chemical anchor rod adopts a reverse-cone design, generally used with injection anchoring adhesive. Its load-bearing principle is the combined effect of chemical bonding and mechanical interlock — the anchoring adhesive provides bond strength, while the reverse cone forms a mechanical interlock with the concrete.
Key features:
Matching adhesive: injection anchoring adhesive (modified epoxy resin)
Rod form: reverse-cone tail, with 7 segments forming the reverse cone
Suitable concrete: suitable for cracked and non-cracked concrete
Application fields: major projects such as rail transit and utility tunnel systems
Curing time: relatively slow, requiring more than 24 hours (strongly affected by temperature)
Large-size advantage: for sizes M24 and above, the ultimate tensile load of reverse-cone anchors can be about 20% higher than that of high-strength chemical anchors20%
2.3 Capsule chemical anchors
Capsule chemical anchors and reverse-cone chemical anchors are essentially the same type of product; the term "capsule" is used to distinguish this type of anchor from ordinary chemical anchors. The top of the capsule chemical anchor features an external hexagon design and it likewise uses injection anchoring adhesive.
Key features:
Matching adhesive: injection anchoring adhesive (modified epoxy resin)
Rod form: flat bottom with a reverse-cone design
Suitable concrete: suitable for cracked and non-cracked concrete
Relationship to reverse-cone anchors: minor differences; generally interchangeable
Origin of the name: "capsule" means the type is set, used to distinguish it from other chemical anchors
Note that some contractors use capsule chemical anchors directly with chemical capsules. Daring testing shows that the adhesive volume in a chemical capsule of the same size is insufficient for capsule anchors, and the mechanical performance is even inferior to that of a same-size high-strength chemical anchor; this combination poses safety risks and is not encouraged。
3. Comparison table of the three types of chemical anchors
| Comparison dimension | High-strength chemical anchor | Reverse-cone chemical anchor | Capsule chemical anchor |
|---|---|---|---|
| Matching adhesive | Chemical capsule (glass tube) | Injection anchoring adhesive | Injection anchoring adhesive |
| Adhesive composition | Unsaturated resin | Modified epoxy resin | Modified epoxy resin |
| Rod form | Ordinary fully threaded rod | Reverse cone | Reverse cone (external hexagon) |
| Cracked concrete suitability | Not suitable | Suitable | Suitable |
| Curing time | Fast (20-30 minutes) | Slow (hours to days) | Slow (hours to days) |
| Large-size load capacity | Baseline | Higher(about +20%) | Higher(about +20%) |
| Price | Lower | Higher | Higher |
| Curtain wall load-bearing suitability | Strictly prohibited | Suitable | Suitable |
4. Key differences between the two adhesive types
The chemical capsule fitted to high-strength chemical anchors and the injection anchoring adhesive fitted to reverse-cone/capsule chemical anchors differ significantly in composition, performance, and curing time:
| Property | Chemical capsule | Injection anchoring adhesive |
|---|---|---|
| Composition | Quartz sand, unsaturated resin, and curing agent | Modified epoxy resin |
| Mechanical properties | Good | Better load capacity when anchoring large-size anchors |
| Stability/durability | Moderate | Excellent |
| Curing time (40°C) | 20-30 minutes | About 24 hours |
| Cracked concrete suitability | Not suitable | Suitable |
| Price | Low | Higher |
Although injection anchoring adhesive costs more and takes longer to cure, it offers better durability and stability and is suitable for cracked concrete. The chemical capsule process is relatively mature, but due to fierce market competition, most products contain diluents added to varying degrees, which degrades mechanical performance.
5. Mandatory requirements for curtain wall load-bearing structures
Per Table 4.1.1-1 of JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures, ordinary chemical anchors are not suitable for tension, edge shear, and combined tension-shear loading conditions。
Some provinces, such as Zhejiang, have issued documents explicitly stipulating:post-installed embedments of building curtain walls shall, in accordance with design requirements, use reliable anchors such as undercut (post-cut) mechanical anchors and capsule chemical anchors; ordinary chemical anchors shall not be used。
The anchor selection requirements for curtain walls are summarized below:
Permitted: undercut mechanical anchors and special reverse-cone chemical anchors (capsule chemical anchors)
Explicitly prohibited: ordinary chemical anchors (high-strength chemical anchors)
Additional requirement: capsule reverse-cone chemical anchors require a high-temperature resistance test report
6. Selection decision guide
Cases where high-strength chemical anchors are preferred
Fixing of non-load-bearing structures: general anchoring scenarios such as equipment supports and pipe fixing
Non-cracked concrete base material: concrete in good condition with no cracking risk
Tight schedules: chemical capsules cure quickly (20-30 minutes), allowing rapid load bearing
Small-size anchors: small sizes such as M8, M10, and M12 are used in large quantities and offer good value for money
Cost-sensitive projects: high-strength chemical anchors are relatively inexpensive
Cases where reverse-cone/capsule chemical anchors are preferred
Curtain wall load-bearing structures: codes mandate the use of special reverse-cone chemical anchors
Cracked concrete base material: ordinary chemical anchors are not suitable; reverse-cone/capsule anchors must be used
Major projects: rail transit, utility tunnel systems, nuclear power projects, etc.
Large-size anchors (M20 and above): the ultimate tensile load of reverse-cone anchors can be about 20% higher than that of high-strength chemical anchors
Long-term durability requirements: injection anchoring adhesive offers better durability
Local codes prohibiting ordinary chemical anchors: regions such as Zhejiang that have issued documents imposing bans
7. Frequently asked questions
| Q1 | What is the difference between capsule chemical anchors and reverse-cone chemical anchors? They are essentially the same type of product, just under different names. "Capsule chemical anchor" is another name for "special reverse-cone chemical anchor"; the term capsule is used to distinguish this type of anchor from ordinary chemical anchors. Both are used with injection anchoring adhesive and are suitable for cracked and non-cracked concrete. |
| Q2 | Why can't high-strength chemical anchors be used for curtain wall load-bearing applications? JGJ 145-2013 stipulates that ordinary chemical anchors are not suitable for tension, edge shear, and combined tension-shear loading conditions. Some regions, such as Zhejiang, have issued documents explicitly prohibiting ordinary chemical anchors in curtain wall projects. High-strength chemical anchors are only suitable for non-cracked concrete, and the adhesive carries an aging risk, so long-term safety cannot be guaranteed. |
| Q3 | Can capsule chemical anchors be used with chemical capsules? Not recommended. Daring testing shows that the adhesive volume in a chemical capsule of the same size is insufficient for capsule anchors, and the mechanical performance is even inferior to that of a same-size high-strength chemical anchor, posing safety risks. Capsule chemical anchors should be used with injection anchoring adhesive. |
| Q4 | How much do the load capacities of the three types of chemical anchors differ? For small sizes (such as M12) tested for ultimate tension on non-cracked concrete, the result is usually rod fracture, and the three perform almost identically. For large sizes (M24 and above), the ultimate tensile load of reverse-cone/capsule chemical anchors can be about 20% higher than that of high-strength chemical anchors. |
| Q5 | What chemical anchor products does Daring offer? The Daring chemical anchor range covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive meeting the national Class A adhesive standard, with grade 5.8 or higher carbon steel or 304/316 stainless steel available. The products offer strong bond anchoring, temperature resistance and seismic performance, and suitability for cracked concrete, and are widely used in various post-installed anchoring applications. |
The Daring chemical anchor range covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive meeting the national Class A adhesive standard, with grade 5.8 or higher carbon steel or 304/316 stainless steel available. The products offer strong bond anchoring, temperature resistance and seismic performance, and suitability for cracked concrete, delivering stable anchoring under static and dynamic loads, and are widely used in various post-installed anchoring applications for concrete and exterior wall structural components. For chemical anchor selection advice for a specific project, please contact the Daring technical team.
References
1. Daring official website — Classification and uses of chemical anchors(basic classification of the three chemical anchor types and adhesive differences)
2. Daring official website — Differences between chemical anchors and mechanical anchors(chemical anchor definition and classification)
3. Daring official website — Differences between high-strength chemical anchors and reverse-cone chemical anchors(detailed comparison of the two anchor types and code requirements)
4. JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures(national industry standard)
5. Curtain wall anchoring: a selection guide for chemical anchors and mechanical anchors(differences between ordinary chemical anchors and reverse-cone capsule chemical anchors)
6. Daring official website — Chemical anchor specifications and models(chemical anchor specifications, models, and customization)