Product Knowledge

How do you select chemical anchors for underground projects? Key points on waterproofing and corrosion protection

Views: 0Posted on: 2026-09-10

The short answer:For chemical anchor selection in underground works, three core principles should be followed:Choose reverse-cone anchors (capsule chemical anchors) for the anchor type, stainless steel for the material, and water-resistant and water-tolerant adhesives for the matching anchoring adhesive. Ordinary chemical anchors (glass tube type) are strictly prohibited for load-bearing structures and cracked concrete; in underground works, preference should be given toreverse-cone chemical anchors, paired with water-resistant and water-tolerant Class A epoxy anchoring adhesive. Regarding material, general underground environments use304 stainless steel, while chloride-containing environments (coastal underground areas and de-icing salt zones in underground parking garages) must use316 stainless steel. For waterproofing, when the hole walls are damp without standing water, perform the three-brush, three-blow hole cleaning procedure and extend the curing time; when there is standing water or continuous seepage at the hole bottom, a purpose-made underwater anchoring adhesive certified for standing water must be used, or the accumulated water must be completely drained. The Daring chemical anchor series is paired with DL-200E modified epoxy injection anchoring adhesive, which offers strong bond anchoring, temperature and seismic resistance, and suits a wide range of installation environments.

Underground works—including metro tunnels, underground utility corridors, basements, and underground parking garages—face harsh conditions such as high humidity and condensation, water seepage, temperature fluctuations, and concrete carbonation. Chemical anchors are exposed to such conditions for long periods, so selection and waterproofing/corrosion protection directly affect the long-term safety of the anchoring system. From the perspectives of anchor type, material selection, adhesive selection, waterproofing, and key installation points, this paper provides a systematic guide for chemical anchor selection in underground works.

I. Key points for chemical anchor selection in underground works

1.1 Anchor types: Ordinary chemical anchors vs reverse-cone chemical anchors

According to JGJ 145-2013, post-installed adhesive-based products are collectively called chemical anchors and are divided into two main categories:

  • Ordinary tube chemical anchors (glass tube chemical bolts): Consisting of a hollow glass tube prefilled with vinyl resin + curing agent + an ordinary straight threaded rod. Load resistance relies solely on adhesive bonding, with no mechanical interlock structure. Suitable for seismic intensity 7 and below, static loads, and non-cracked concrete,but strictly prohibited for load-bearing components under seismic intensity 8 or dynamic loads. Ordinary chemical anchors are strictly prohibited for load-bearing structures and cracked concrete.

  • Reverse-cone chemical anchors (reverse-cone anchors): Consisting of a one-piece forged multi-stage reverse-cone toothed threaded rod + injected Class A epoxy anchoring adhesive. The load-resisting mechanism isdual locking by epoxy adhesive bonding + mechanical bearing of the reverse-cone teeth, with the grip tightening as tensile force increases. It offers advantages such as suitability for cracked concrete, 2,000,000-cycle fatigue resistance, compliance for seismic intensity 8, and usability in damp basements, making it the mainstream load-bearing choice for strengthening, curtain walls, and equipment foundations.

In underground works, anchoring of load-bearing structuresmust use reverse-cone chemical anchors or undercut mechanical anchors. According to Article 16.1.5 of GB 50367-2013, when anchors are used in load-bearing structures in seismic fortification zones, undercut anchors or reverse-cone adhesive anchors should be used, and they are only permitted for buildings with a fortification intensity not higher than 8 and built on Class I or II sites.

Special vigilance is required: when drawings specify "reverse-cone chemical anchors" or "seismic chemical anchors," construction procurement must not substitute glass tube straight-rod chemical bolts; third-party pull-out tests and plan review will directly judge them non-compliant. The seismic chapter of JGJ 145-2013 only recognizes reverse-cone adhesive anchors, and ordinary tube chemical bolts have no seismic certification.

1.2 Material selection: 304 vs 316 stainless steel

According to Article 4.1.2 of JGJ 145-2013, metal anchors should be provided with corrosion protection appropriate to the service environment category. In outdoor environments, permanently humid indoor environments, coastal areas, and atmospheres with high acidity or alkalinity,stainless steel anchors should be used, and highly corrosion-resistant stainless steel should be used in chloride-containing environments.

Environmental conditionRecommended materialTime to red rust in salt spray test
Dry indoor environmentsHot-dip galvanized carbon steel (≥45 μm)Approx. 79 hours
Damp underground environments (no chloride ions)304 stainless steel (A2-70)Approx. 303 hours
Chloride-containing environments (coastal underground areas, de-icing salt zones)316 stainless steel (A4-70)Approx. 550 hours

316 stainless steel contains an additional 2%-3% molybdenum, greatly improving resistance to chloride corrosion; its corrosion-resistant service life is about 7 times that of hot-dip galvanized steel, while 304 stainless steel is about 4 times. In underground works, 304 stainless steel may be used in general underground environments, but chloride-containing environments such as coastal underground works and de-icing salt zones in underground parking garagesmust use 316 stainless steel。

1.3 Matching adhesives: Water-resistant and water-tolerant Class A epoxy anchoring adhesive

The matching adhesive for chemical anchors in underground works should meet the following requirements:

  • Class A adhesive certification: The chemical anchoring agent should pass the complete Class A adhesive testing and certification, and the Class A adhesive report should include, but not be limited to, resistance-to-medium-erosion tests, including certifications for salt spray resistance, seawater immersion resistance, acid resistance, and alkali resistance.

  • Water-resistant and water-tolerant: Select a water-resistant and water-tolerant Class A epoxy anchoring adhesive that can cure in damp holes and resist weak acid corrosion from groundwater. Daring DL-200E modified epoxy injection anchoring adhesive meets the national Class A adhesive standard, offering strong bond anchoring, temperature and seismic resistance.

  • Damp condition certification: Installation in damp substrates must undergo damp-condition certification testing, and dry-hole parameters cannot be applied directly. The load capacity is reduced under damp conditions, so values must be taken from the certified load capacity under damp conditions stated in the adhesive material report.

II. Key points of waterproofing in underground works

2.1 Three levels of damp conditions

At underground worksites, different measures should be taken according to the actual degree of moisture in the holes:

Condition levelHole conditionTreatment measure
Dry holesHole walls dry with no moistureInstall according to the standard procedure
Damp condensation holesA water film exists on the hole walls, damp to the touch but without obvious standing waterOrdinary Class A modified epoxy adhesive may be used, but thethree-brush, three-blowhole-cleaning procedure must be strictly carried out, combined with hot-air drying.
Standing water holesStanding water or continuous seepage at the hole bottomOrdinary Class A epoxy adhesiveis strictly prohibited from direct use;a purpose-made anchoring adhesive certified for standing water or underwater conditions must be used instead, or the accumulated water must be completely drained.

2.2 Installation process in damp environments

For installation of chemical anchors in damp environments in underground works, the following key steps should be added to the standard procedure:

  • Drilling: The drill bit and matching tools specified in the product data sheet must be used, the hole depth must follow the design requirements, and the hole position should be adjusted appropriately if rebar is encountered.

  • Hole cleaning (the most critical step): Hole cleaning in damp environments is more stringent than in dry environments. Blow out the hole with a dust blower at least 2 times → clean the hole walls with a dedicated brush at least 2 times → blow again until no dust emerges from the hole. Special treatment for damp holes: repeatedly wipe the hole walls with dry cotton cloth, or dry with a heat gun; in more humid conditions, use a heating rod for drying. Any accumulated water in the hole must be completely removed.

  • Adhesive injection and anchor installation: Inject the adhesive at a uniform rate starting from the hole bottom, controlling the amount at 1/2 to 2/3 of the hole depth; slowly rotate the anchor into the hole in one direction until the design embedment depth is reached, with a small amount of adhesive overflowing from the hole mouth after insertion.

  • Curing wait: In damp environments, the curing time must be doubled. Disturbance of the installed anchor is strictly prohibited, and sufficient curing time must be allowed according to the substrate temperature and degree of moisture.

Incomplete hole cleaning is the greatest quality risk in chemical anchor installation under damp conditions. Residual dust and moisture in the hole form an isolating layer that prevents any high-performance adhesive from effectively bonding to the concrete surface. Inadequate hole cleaning and installation with water and dust present are the leading causes of failed pull-out tests later.

2.3 Waterproof layer repair and acceptance

After chemical anchor installation is completed, it is recommended to reapply the waterproof layer or conduct another water retention test after the anchors are installed, to ensure complete reliability. After installation, the anchoring develops high load capacity, is not prone to displacement or pull-out, and provides good adhesion. In principle, a qualified chemical anchor resists water penetration and exerts no expansion stress; if installation strictly follows the procedures, the chemical anchor itself will not cause water seepage (between the adhesive and the original structure, or between the adhesive and the anchor). However, underground works have extremely high waterproofing requirements, so waterproof layer repair and a water retention test should be carried out for acceptance.

III. Key points of corrosion protection in underground works

3.1 Corrosion protection measures for anchors

According to Article 4.1.2 of JGJ 145-2013:

  • Carbon steel and alloy steel mechanical anchorsshould receive zinc coating for corrosion protection, with an average electroplated zinc layer thickness of not less than 5 μm and an average hot-dip galvanized layer thickness of not less than 45 μm.

  • Outdoor environments, permanently humid indoor environments, coastal areas, and atmospheres with high acidity or alkalinityrequire stainless steel anchors.

  • Chloride-containing environmentsrequire highly corrosion-resistant stainless steel (such as 316 stainless steel).

In underground works, anchors remain in high-humidity environments for long periods, so 304 or 316 stainless steel should be preferred. For carbonated, loose concrete in older renovation sections, all threaded rods should be upgraded to class 8.8 hot-dip galvanized steel (coating ≥55 μm) or stainless steel to resist moisture-induced corrosion.

3.2 Corrosion protection requirements in special environments

  • Chloride-containing environments: such as coastal underground works, de-icing salt zones in underground parking garages, and indoor swimming pools. Ordinary stainless steel is not suitable for chloride-containing environments; 316 stainless steel or a higher grade of highly corrosion-resistant stainless steel must be used.

  • High-acidity/alkalinity environments: In places such as chemical underground utility corridors, highly corrosion-resistant stainless steel should be used, together with acid- and alkali-resistant Class A adhesive.

  • De-icing salt zones in underground parking garages: In winter, de-icing salts seep underground, resulting in high chloride concentrations; 316 stainless steel anchors should be used.

3.3 Corrosion protection for fasteners

The corrosion coating for fasteners may be hot-dip galvanizing + alkali-resistant anti-corrosion coating, or multi-alloy diffusion + alkali-resistant anti-corrosion coating, and the alkali-resistant anti-corrosion coating should be applied in two coats during production. The materials of back bolts, pendants, and connecting bolts should be matched to avoid galvanic corrosion between dissimilar metals. In underground works, it is recommended that anchors, nuts, and washers all be made of stainless steel to avoid galvanic corrosion.

IV. Comprehensive decision-making for chemical anchor selection in underground works

Project scenarioRecommended anchor typeRecommended materialRecommended adhesive
Metro tunnels (high humidity and condensation)Reverse-cone chemical anchors304/316 stainless steelWater-resistant and water-tolerant Class A epoxy adhesive
Underground utility corridors (damp environments)Reverse-cone chemical anchors304 stainless steelClass A epoxy anchoring adhesive
Basements (dry areas)Reverse-cone chemical anchors/undercut anchors304 stainless steelClass A epoxy anchoring adhesive
Coastal underground works (containing chloride ions)Reverse-cone chemical anchors316 stainless steel (mandatory)Water-resistant and water-tolerant Class A epoxy adhesive
De-icing salt zones in underground parking garagesReverse-cone chemical anchors/undercut anchors316 stainless steel (mandatory)Class A epoxy anchoring adhesive
Standing water/seepage conditionsReverse-cone chemical anchors316 stainless steelPurpose-made underwater anchoring adhesive (mandatory)
Older renovation sections (carbonated, loose concrete)Reverse-cone chemical anchors (group anchor arrangement)Class 8.8 hot-dip galvanized (≥55 μm) or stainless steelHigh-penetration bonding adhesive

V. FAQ

Q1How should chemical anchors be selected for underground works?
Follow three core principles: choose reverse-cone chemical anchors for the anchor type (ordinary tube chemical anchors are strictly prohibited), choose stainless steel for the material (304 for general underground environments and 316 for chloride-containing environments), and choose water-resistant and water-tolerant Class A epoxy anchoring adhesive as the matching adhesive.
Q2Should 304 or 316 stainless steel be used for chemical anchors in underground works?
304 stainless steel may be used in general damp underground environments (without chloride ions); 316 stainless steel must be used in chloride-containing environments such as coastal underground works, de-icing salt zones in underground parking garages, and indoor swimming pools. The corrosion-resistant service life of 316 stainless steel is about 1.8 times that of 304.
Q3How should waterproofing be handled for chemical anchors in underground works?
When the hole walls are damp without standing water, perform the three-brush, three-blow hole cleaning procedure and use hot-air drying, with the curing time doubled; when there is standing water or continuous seepage at the hole bottom, a purpose-made underwater anchoring adhesive certified for standing water must be used or the accumulated water completely drained. After installation, it is recommended to reapply the waterproof layer or conduct a water retention test.
Q4Can ordinary chemical anchors be used in underground works?
Ordinary chemical anchors are strictly prohibited for load-bearing structures. Ordinary tube chemical anchors rely solely on adhesive bonding, have no mechanical interlock structure, are strictly prohibited for load-bearing components under seismic intensity 8 or dynamic loads, and have no certification for use in damp basements. Underground works should use reverse-cone chemical anchors.
Q5Are Daring chemical anchors suitable for underground works?
Yes. The Daring chemical anchor series is paired with DL-200E modified epoxy injection anchoring adhesive, which offers strong bond anchoring, temperature and seismic resistance, and suits a wide range of installation environments. Daring capsule chemical anchors feature a reverse-cone structural design and, paired with DL-200E modified epoxy injection anchoring adhesive, have passed multiple tests including Class S anchor certification, 2,000,000-cycle fatigue resistance, 120-minute fire resistance, and seismic testing.

The Daring chemical anchor series covers high-strength, capsule, reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Class A adhesive standard. Carbon steel of grade 5.8 or above (hot-dip galvanized ≥45 μm) or 304/316 stainless steel is available. Daring capsule chemical anchors feature a reverse-cone structural design and, through a dual load-resisting mechanism of chemical bonding + mechanical interlock, have passed multiple tests including Class S anchor certification, 2,000,000-cycle fatigue resistance, 120-minute fire resistance, and seismic testing, making them suitable for damp environments such as underground works. For chemical anchor selection and waterproofing/corrosion protection advice for a specific underground project, please consult the Daring technical team.

References

JGJ 145-2013 Technical Specification for Post-Installed Anchoring of Concrete Structures - Anchor selection, corrosion protection measures, and installation requirements in damp environments

GB 50367-2013 Code for Design of Concrete Structure Strengthening - Provisions on anchor selection for load-bearing structures