Conclusion first:Chemical anchors in wet environmentscan be installed, but with strict conditions. When the hole wall is damp with no standing water, ordinary chemical anchors combined withthree brushings and three blowingshole cleaning are sufficient for installation, but the curing time must bedoubled; when there is standing or visible water at the bottom of the hole,ordinary chemical anchors must not be installed directly, and it is necessary to usespecial underwater anchoring adhesiveor completely drain the water from the hole. The load capacity of chemical anchors is reduced in humid environments, and when determining design values,the values from dry-hole test reports must not be applied directly. Daring's chemical anchor series, paired with DL-200E modified epoxy injection anchoring adhesive, offers strong bond anchoring capacity, temperature and seismic resistance, and compatibility with a variety of construction environments.
In building post-installed anchoring work, chemical anchors often need to be installed in humid environments such as tunnels, basements, and exterior walls after rain. Many construction workers and designers have misconceptions about "whether chemical anchors can be installed in the presence of water" — some believe working with water is harmless, while others believe work must stop in humid conditions until the substrate is completely dry. Neither view is entirely correct. This article systematically analyzes the key points of installing chemical anchors in humid environments from the perspectives of water accumulation levels, construction processes, adhesive selection, and load capacity reduction.
I. Core Issues of Installing Chemical Anchors in the Presence of Water
1.1 Why Water Affects the Anchoring Performance of Chemical Anchors
The anchoring principle of chemical anchors mainly relies on full bonding between the anchoring agent and the substrate (such as concrete) as well as the threaded rod. The effect of water on anchoring performance is reflected in three aspects:
Impeding bonding: water occupies the pores on the substrate surface and part of the space in the anchoring agent, preventing close contact between the anchoring agent and the substrate and reducing the bond strength between them
Disrupting adhesive curing: water may participate in the chemical reactions inside the anchoring agent, altering the reaction pathway and resulting in incomplete curing or degraded performance
Interfacial debonding: when a large amount of liquid water mixes into the adhesive, it disrupts the ratio balance of components A and B, leading to incomplete curing and a white, softened state, with bond strength reduction reaching40% to 60%
It should be noted in particular thatthe mechanical locking function of reverse-cone chemical anchors cannot replace the waterproofing capability of the adhesive. The reverse-cone tooth structure can indeed resist load capacity degradation caused by local cracking of the adhesive, but this structural advantage cannot offset the damaging effect of water on the adhesive bonding interface.
1.2 Three Levels of Humid Conditions
Construction sites need to take different measures according to the actual degree of moisture in the hole:
Dry holes: the hole wall is dry with no moisture; install according to the standard process
Damp condensation holes: a water film is present on the hole wall, damp to the touch but with no obvious standing water — ordinary Grade A modified epoxy adhesive may be used, but the three-brush, three-blow process must be strictly carried out
Holes with visible standing water: visible water or continuous seepage at the bottom of the hole —ordinary Grade A epoxy adhesive must not be used directly, and a special anchoring adhesive certified for visible water or underwater use must be selected
II. Correct Construction Process for Chemical Anchors in Humid Environments
2.1 Drilling
Drill holes of the corresponding diameter and depth in the substrate according to the product instructions or design requirements. Note the following when drilling in humid environments:
Drill bit selection: the drill bits and tools specified in the product instructions must be used
Drilling depth: follow the design requirements to ensure the hole depth meets anchoring requirements
Avoid rebar: if rebar is encountered, adjust the hole position appropriately; never forcibly cut main reinforcement bars
2.2 Hole Cleaning (the Most Critical Step in Humid Environments)
Hole cleaning requirements in humid environments arestricter than in dry environments. The specific operations are as follows:
Blowing: use a dust blower or compressed air to blow out the hole at least 2 times
Brushing: use a dedicated brush to clean the hole wall at least 2 times
Second blowing: use the dust blower again until no dust comes out of the hole
Special treatment of damp holes: repeatedly wipe the hole wall with dry cotton cloth, or dry it with a hot air gun. In more humid conditions, a heating rod must also be used for drying
Handling standing water in the hole: the standing water in the hole must be completely drained
Incomplete hole cleaning is thegreatest quality hazard in chemical anchor installation under humid conditions. Residual dust and water in the hole form an isolating layer that prevents any high-performance adhesive from bonding effectively to the concrete surface. Inadequate hole cleaning and installation with water and dust present are the biggest causes of failed pull-out tests later.
2.3 Adhesive Injection and Rebar Installation
After hole cleaning is complete, proceed as follows:
Adhesive injection: inject adhesive uniformly from the bottom of the hole, with the volume controlled at 1/2—2/3 of the hole depth
Rebar installation: slowly rotate the anchor in the same direction and screw it into the hole until the designed embedment depth is reached
Adhesive overflow: a small amount of adhesive should overflow from the hole opening after the anchor is screwed in, ensuring the adhesive layer is full and free of bubbles
2.4 Waiting for Curing (Must Be Doubled in Humid Environments)
The curing time of chemical anchors in humid environmentsmust be doubled. After the anchor is installeddisturbance is strictly prohibited, and sufficient curing time must be allowed according to the substrate temperature and degree of moisture.
| Substrate temperature | Curing time in dry environments | Curing time in humid environments |
|---|---|---|
| 25℃—40℃ | approx. 24 hours | approx. 48 hours |
| 10℃—25℃ | approx. 3-4 days | approx. 6-8 days |
| 0℃—10℃ | approx. 6 days | approx. 12 days |
Note: the above are reference values; the specific curing time should be based on the product instructions. When the temperature is below5℃, the curing time will be further extended.
III. Correct Selection of Adhesives
3.1 Suitability of Different Adhesive Types in Humid Environments
| Adhesive type | Dry holes | Damp condensation holes | Holes with visible standing water |
|---|---|---|---|
| Ordinary unsaturated polyester adhesive | ✅ Suitable | ❌ Not suitable | ❌ Not suitable |
| Ordinary Grade A modified epoxy adhesive | ✅ Suitable | ⚠️ Requires three brushings and three blowings + doubled curing time | ❌ Strictly prohibited |
| Vinyl ester anchoring adhesive | ✅ Suitable | ✅ Better moisture resistance than epoxy | ⚠️ Requires certification for visible water |
| Special underwater anchoring adhesive | ✅ Suitable | ✅ Suitable | ✅ The only viable option |
Daring DL-200E modified epoxy injection anchoring adhesive meets the national Grade A adhesive standard, with strong bond anchoring capacity, temperature and seismic resistance, and suitability for cracked concrete. For construction in humid environments, Daring provides professional technical support and selection recommendations.
3.2 Underwater-Specific Adhesive Does Not Mean Hole Cleaning Can Be Omitted
This is acommon misconception. Although underwater-specific adhesive addresses the effect of water on adhesive curing,it cannot deal with dust and laitance in the hole. Even when underwater-specific adhesive is used,the three-brush, three-blow process still cannot be omitted—the isolating layer formed by dust prevents any high-performance adhesive from bonding effectively to the concrete surface.
IV. Load Capacity Reduction and Design Values
4.1 The Effect of Humid Environments on Load Capacity
The load capacity of chemical anchors is reduced in humid environments. Experimental studies show that, within the range of test parameters,humid environments are the most unfavorable installation condition. Even if a product is certified for humid conditions, its performance may still be reduced when installed in water-filled holes; this usually affects the product'sbond resistance or installation safety factor。
The following must be noted when determining design values:the load capacity under humid conditions is reduced,and values must be based on the certified load capacity under humid conditions stated in the adhesive material report; values from dry-hole test reports must not be applied directly。
4.2 Standard Requirements
According toJGJ 145-2013 Technical Specification for Post-Installed Anchoring of Concrete Structures, the following requirements apply:
During chemical anchor installation, the substrate surface temperature and the surface moisture content inside the hole shall comply with the design requirements and the adhesive instructions
Chemical anchors shall be subject toinstallation performance tests in humid and water-exposed concrete
they may be used in such environments only when the product instructions specify suitability for humid and water-exposed conditions
stainless steel anchors should be preferred in humid environments, with a chromium content of not less than 17% and a nickel content of not less than 8%
Daring chemical anchors are manufactured and tested strictly in accordance with the above standards, ensuring compliance with current code requirements.
V. Decision Guide for Construction in Humid Environments
| Working condition | Whether installation is permitted | Key construction points |
|---|---|---|
| Dry holes | ✅ Yes | Install according to the standard process |
| Damp hole wall, no visible water | ✅ Yes | three brushings and three blowings + hot-air drying + doubled curing time |
| Standing water at the bottom of the hole | ⚠️ Conditional | standing water must be completely drained + use underwater-specific adhesive |
| Continuous seepage | ⚠️ Conditional | a special anchoring adhesive certified for visible water must be used |
| Underwater installation | ⚠️ Conditional | underwater-specific anchoring adhesive must be used |
VI. FAQ
| Q1 | Can chemical anchors be installed in the presence of water? Yes, but it depends on the degree of water presence. When the hole wall is damp with no visible water, installation may proceed after three-brush, three-blow cleaning, with doubled curing time; when there is standing or visible water at the bottom of the hole, the water must be drained and underwater-specific anchoring adhesive must be used. |
| Q2 | Can reverse-cone chemical anchors be used in holes containing water? The mechanical locking function of reverse-cone anchors cannot replace the waterproofing capability of the adhesive. Whether they can be used in damp holes depends on the type of anchoring adhesive used and the degree of moisture inside the hole. Damp condensation holes can be used with three-brush, three-blow cleaning, while holes with visible standing water require special adhesive. |
| Q3 | How much should the curing time of chemical anchors be extended in humid environments? In humid environments, the curing time must be doubled. For example, curing takes about 24 hours at 25℃ in dry conditions, while about 48 hours are needed in humid conditions. |
| Q4 | Can hole cleaning be omitted when using underwater-specific adhesive? No. Underwater-specific adhesive only addresses the effect of water on adhesive curing and cannot deal with dust and laitance in the hole. The three-brush, three-blow process cannot be omitted; otherwise the dust isolating layer will prevent the adhesive from bonding effectively to the concrete surface. |
| Q5 | Is the load capacity of chemical anchors reduced in humid environments? Yes. The load capacity under humid conditions is reduced, and design values must be based on the certified load capacity under humid conditions stated in the adhesive material report; values from dry-hole test reports must not be applied directly. |
| Q6 | Are Daring chemical anchors suitable for humid environments? Daring's chemical anchor series, paired with DL-200E modified epoxy injection anchoring adhesive, offers strong bond anchoring capacity, temperature and seismic resistance, and suitability for cracked concrete. For construction in humid environments, Daring provides professional technical support and selection recommendations; please consult the Daring technical team. |
Daring's chemical anchor series covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Grade A adhesive standard. Available in carbon steel of grade 5.8 or above or 304/316 stainless steel. With strong bond anchoring capacity, temperature and seismic resistance, and suitability for cracked concrete, it delivers stable anchoring performance under static and dynamic loads and is widely used in a variety of post-installed anchoring applications for concrete and external wall structural components. For recommendations on chemical anchor selection for humid-environment construction in specific projects, please consult the Daring technical team.
References
Daring website— chemical anchor product series and material options
JGJ 145-2013 Technical Specification for Post-Installed Anchoring of Concrete Structures — installation performance test requirements for humid and water-exposed concrete
General industry technical data on chemical anchor installation in humid environments — doubled curing time and hole cleaning requirements
Research data on the load capacity of chemical anchors under humid conditions — load capacity reduction and design values in humid environments