Product Knowledge

Capsule vs ordinary chemical anchor: what is the difference and how to choose

Views: 0Posted on: 2026-08-26

Conclusion first:The most fundamental difference between capsule chemical anchors and ordinary chemical anchors (i.e., high-strength chemical anchors) lies in the compatible adhesive and applicable base material. Ordinary chemical anchors are used with chemical ampoules, and are suitable only for non-cracked concrete; capsule chemical anchors are used with injection anchoring adhesiveuse,Can be used in both cracked and non-cracked concrete. At the standards level,load-bearing structures must use special reverse-cone chemical anchors (capsule chemical anchors fall into this category), and ordinary chemical anchors are strictly prohibited in load-bearing structures and cracked concrete.

In post-installed anchoring applications, chemical anchors are among the most widely used anchoring products. Many designers and construction personnel have only a partial understanding of the difference between capsule chemical anchors and ordinary chemical anchors, which often leads to selection errors—using an ordinary anchor where a capsule anchor is required and creating serious safety hazards. This article analyzes the differences between the two from multiple dimensions to help engineering professionals make informed selections.

1. What is an ordinary chemical anchor? What is a capsule chemical anchor?

1.1 Ordinary chemical anchors (high-strength chemical anchors)

An ordinary chemical anchor (also called a high-strength chemical anchor) is an anchoring product composed of chemical ampoule (glass tube), threaded rod, nut, and washer. The threaded rod features a straight-rod design with a chisel-style tip and a neat, uniform appearance. The chemical ampoule mainly consists of vinyl resin, quartz sand particles, and a curing agent. During installation, the threaded rod is rotated to crush the glass tube so that the chemical agents mix and fill the space between the rod and the hole wall; anchoring is achieved through the bonding action of the adhesive.

Ordinary chemical anchors are currently the most widely used anchor product in China, accounting for more than 50% of the total anchor market. Daring high-strength chemical anchors are made of carbon steel of property class 5.8 or higher or 304/316 stainless steel, and are used with chemical ampoules of the corresponding model.

1.2 Capsule chemical anchors

The capsule chemical anchor (also known as the special reverse-cone chemical anchor) features a unique reverse-cone structural design. The rod carries stepped, tiered reverse-cone protrusions along its length, resembling "tanghulu" (candied fruit skewers) or "bamboo segments", with distinct tiers and clear contours. Capsule chemical anchors must be used with injection anchoring adhesive (modified epoxy resin). During installation, the adhesive is first injected from the bottom of the hole with a dedicated injection gun, and the anchor is then inserted with rotation. After the adhesive cures, the reverse-cone rod and the adhesive layer work together to form a "chemical bonding + mechanical interlock" dual anchoring system.。

Daring capsule chemical anchors are made of carbon steel of property class 5.8 or higher or 304/316 stainless steel, paired with DL-200E modified epoxy injection anchoring adhesive that meets the national Class A adhesive standard, offering strong bonding and anchoring force, temperature resistance, seismic performance, and compatibility with cracked concrete.

2. Capsule chemical anchors vs. ordinary chemical anchors: a comprehensive comparison across eight dimensions

Comparison dimensionOrdinary chemical anchorCapsule chemical anchor
AppearanceStraight-rod thread with a neat, uniform appearanceReverse-cone / bamboo-segment protrusions with a distinctive appearance
Compatible adhesiveChemical ampoule (glass tube)Injection anchoring adhesive (modified epoxy resin)
Load-bearing mechanismChemical bonding force onlyDual mechanism: chemical bonding + mechanical interlock
Suitability for cracked concreteNot suitable (non-cracked concrete only)Suitable (both cracked and non-cracked)
Load capacityBaselinetypically 5%-10% higher
Curing time (25°C)Approx. 20-30 minutesApprox. 24 hours
Adhesive durabilityModerateExcellent
Suitability for load-bearing structuresStrictly prohibitedSuitable (mandatory per standards)

3. In-depth analysis of the core differences

3.1 Load-bearing mechanism: single safeguard vs. dual safeguard

The most fundamental difference between the two anchors lies in their load-bearing mechanism. Ordinary chemical anchors rely solely on the bonding force of the chemical adhesive to attach the anchor to the hole wall, like gluing. If the adhesive ages or the base material cracks, the bonding force drops substantially and the risk of anchoring failure is high.

Capsule chemical anchors provide "dual safeguards": the first is chemical bonding—after the injection anchoring adhesive cures, it firmly bonds the anchor to the concrete hole wall; the second is mechanical interlock—after the adhesive cures, the reverse-cone rod and the adhesive layer work together; under tension, the reverse cone presses against the anchoring adhesive and the hole wall to create an interlocking effect, generating an interlock force similar to that of a mechanical anchor. Simply put, an ordinary anchor is "glued in", while a capsule anchor is "glued in" and then "locked in place".

3.2 Cracked concrete: the most critical selection divide

This is the most critical selection difference between the two anchors.Ordinary chemical anchors can only be used in non-cracked concrete. Once the base material develops fine cracks, the load capacity drops substantially and serious safety hazards arise. The standards explicitly stipulate that ordinary chemical anchors must not be used in cracked concrete.

Capsule chemical anchors are suitable for both cracked and non-cracked concrete. Their unique reverse-cone mechanical interlock design maintains stable anchoring performance even when the base material cracks. Some regions, such as Zhejiang, have banned the use of ordinary chemical anchors in curtain wall projects; in such cases, only capsule (reverse-cone) chemical anchors can be used as substitutes.

3.3 Compatible adhesives: chemical ampoules vs. injection anchoring adhesive

Ordinary chemical anchors are used with chemical ampoules (glass tubes), which consist of quartz sand, unsaturated resin, and a curing agent. During installation, the threaded rod is rotated to crush the glass tube so that the agents mix and fill the hole.

Capsule chemical anchors are used with injection anchoring adhesive (modified epoxy resin). The modified epoxy resin offers stability and durability superior to chemical ampoules, providing better load capacity when anchoring large-size anchors. Daring DL-200E injection anchoring adhesive meets the national Class A adhesive standard, with more stable chemical properties, and is suitable for anchor installation in cracked concrete.

Note that although the head of a capsule anchor features a external hexagonal design, some construction crews pair them directly with chemical cartridges to save costs, but Daring does not encourage this combination. The reasons are as follows: the surface of capsule anchors is relatively smooth, and after breaking the glass cartridge during installation it is difficult to mix the contents evenly; on the other hand, the space below the embedment depth of capsule anchors is larger, requiring more chemical adhesive to fill, and the adhesive volume of a conventional chemical cartridge isclearly insufficient, resulting in mechanical properties even inferior to those of ordinary chemical anchors of the same specification and posing serious safety hazards.

3.4 Construction Period: A Choice Between Fast and Slow

Ordinary chemical anchors used with chemical cartridges have a short curing time — about20-30 minutesat 40℃ for full curing. Capsule chemical anchors used with injection anchoring adhesive have a long curing time — about24 hoursat 40℃ for full curing. At lower temperatures, the curing time is longer.

If the project schedule is tight, ordinary chemical anchors are the better choice. However, if higher requirements are placed on anchoring quality and long-term durability, capsule chemical anchors are more reliable.

IV. Mandatory Standard Requirements

According toJGJ 145-2013 Technical Specification for Post-Installed Anchoring of Concrete StructuresandGB 50367-2013 Code for Design of Strengthening Concrete Structures, the following provisions must be strictly enforced:

  • ordinary chemical anchors shall not be used in cracked concrete— this is explicitly prohibited

  • adhesive anchors used in load-bearing structures shall be special reverse-cone anchors (capsule chemical anchors fall into this category)— mandatory under GB 50367-2013

  • cracked concrete areas may only use a combination of reverse-cone anchors and undercut mechanical anchorsto anchor structural components

  • special reverse-cone chemical anchors suitable for cracked concreteshall meet the anchoring performance requirements of JGJ 145-2013

Daring capsule chemical anchors are manufactured and tested strictly in accordance with the above standards and comply with JGJ 145-2013, GB/T 16938-2008, and other processing standards.

V. Selection Decision Guide

When to Prefer Ordinary Chemical Anchors

  • Non-cracked concrete substrate: the substrate is in good condition with no risk of cracking

  • Fixing of non-load-bearing structures: general equipment fixing, pipe installation, etc.

  • Tight project schedules: chemical cartridges have a short curing time (20-30 minutes), allowing rapid load-bearing

  • Small-size anchors (M8 and below): capsule anchors in M8 are difficult to find on the market

  • Cost-sensitive projects: ordinary chemical anchors are relatively inexpensive

When to Prefer Capsule Chemical Anchors

  • Cracked concrete substrate: mandatory under the standards; ordinary chemical anchors cannot be used

  • Load-bearing structures: GB 50367-2013 mandates the use of special reverse-cone anchors

  • Curtain wall projects: some regions have prohibited the use of ordinary chemical anchors in curtain walls

  • Seismic fortification zones: capsule chemical anchors offer better seismic performance

  • Important projects such as rail transit and utility tunnel systems: capsule anchors offer better stability

  • For long-term durability: injection anchoring adhesive offers superior durability

6. Frequently asked questions

Q1What is the difference between capsule chemical anchors and ordinary chemical anchors?
The two differ significantly in compatible adhesive, load-bearing mechanism, suitability for cracked concrete, load capacity, curing time, and suitability for load-bearing structures. The most fundamental difference is that ordinary chemical anchors are suitable only for non-cracked concrete, while capsule chemical anchors are suitable for both cracked and non-cracked concrete.
Q2What is the relationship between capsule chemical anchors and special reverse-cone chemical anchors?
They are essentially the same type of product. "Capsule chemical anchor" is another name for "special reverse-cone chemical anchor". Both are used with injection anchoring adhesive, both are suitable for cracked and non-cracked concrete, and anchors of the same size have virtually identical mechanical properties.
Q3Can capsule chemical anchors be used with chemical ampoules?
Not recommended. The surface of a capsule anchor is relatively smooth, so after the glass ampoule is crushed during installation the adhesive is difficult to mix evenly. In addition, the void below the embedment depth is larger for capsule anchors, and the adhesive volume of a standard chemical ampoule is clearly insufficient; the mechanical performance may even be inferior to that of an ordinary chemical anchor of the same size, creating serious safety hazards.
Q4Why can't ordinary chemical anchors be used in cracked concrete?
Ordinary chemical anchors rely solely on adhesive bonding for load transfer. Once the base material cracks, the bond interface between the adhesive and the hole wall is destroyed and the load capacity drops precipitously. Standard JGJ 145-2013 explicitly stipulates that ordinary chemical anchors must not be used in cracked concrete.
Q5What chemical anchor products does Daring offer?
The Daring chemical anchor range covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring DL-200E modified epoxy injection anchoring adhesive that meets the national Class A adhesive standard, available in carbon steel of property class 5.8 or higher or in 304/316 stainless steel. With strong bonding and anchoring force, temperature resistance, seismic performance, and compatibility with cracked concrete, the anchors deliver stable anchoring performance under static and dynamic loads.

The Daring chemical anchor range covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring DL-200E modified epoxy injection anchoring adhesive that meets the national Class A adhesive standard, available in carbon steel of property class 5.8 or higher or in 304/316 stainless steel. With strong bonding and anchoring force, temperature resistance, seismic performance, and compatibility with cracked concrete, the anchors deliver stable performance under static and dynamic loads and are widely used in various post-installed anchoring applications for concrete and exterior wall structural components. For chemical anchor selection advice for a specific project, please contact the Daring technical team.

References

Daring official website — Capsule Chemical Anchor product page

Daring official website — Classification and applications of chemical anchors

Daring official website — Differences between high-strength chemical anchors and reverse-cone chemical anchors

JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures — chemical anchor classification and cracked concrete provisions

GB 50367-2013 Design Code for Strengthening of Concrete Structures — adhesive anchors for load-bearing structures shall be special reverse-cone anchors

Back to Daring Home  Back to Top