How to determine the effective embedment depth of a post-undercut mechanical anchor

Views: 0Posted on: 2026-08-20

To start with the conclusion:The effective anchoring depth hef of the post-installed undercut mechanical anchor refers to the depth of the anchor's expansion cone at the point of maximum squeeze against the hole wall. The hef valueshould be based on the effective anchoring depth stated in the anchor product manual, rather than simply applying empirical formulas such as "embedment depth = 8d". Taking the Daring undercut anchor as an example, the standard M12 product has an effective embedment depth of80mmor100mm, two specifications; for M16 it is100mmor120mm. The rod of the Daring undercut anchor features anembedment depth linemarking; during installation, drive until the embedment depth line is flush with the base material surface, indicating that the anchor is fully installed. The hef value chosen in design directly determines the concrete cone failure load capacity,and an incorrect hef value can leave the anchoring system with serious safety hazards。

In building post-installed anchoring projects, the post-installed undercut mechanical anchor (also known as the die-undercut anchor or post-cut anchor) is one of the anchoring products most recommended by building codes thanks to its mechanical interlock effect. However, many designers and installers misunderstand how to determine the "effective anchoring depth hef", leading to incorrect selection or non-compliant installation. Based on JGJ 145-2013 Technical Specification for Post-Installed Fastenings in Concrete Structures and GB 50367-2013 Design Code for Strengthening of Concrete Structures, this article systematically explains how to determine the effective anchoring depth of post-installed undercut mechanical anchors.

I. What Is Effective Anchoring Depth hef

According to JGJ 145-2013 Technical Specification for Post-Installed Fastenings in Concrete Structures,the effective anchoring depth hefis the depth over which load is effectively transferred between the anchor and the concrete base material. For undercut anchors (including post-installed undercut anchors), hef is defined asthe depth of the expansion cone at the point of maximum squeeze against the hole wall. This depth directly determines the anchor's anchoring capacity — the larger the hef, the higher the concrete cone failure load capacity.

Unlike drilling depth, the effective anchoring depth hef isa product-specific parameter, determined by the anchor's structural design rather than simply the drilling depth. The hef of an undercut anchor is usually smaller than the drilling depth (because the drilling depth includes the height of the undercut section).

II. Basis for Selecting hef: the Product Manual Comes First

According to Clause 16.3.2 of GB 50367-2013 Design Code for Strengthening of Concrete Structures and the relevant provisions of JGJ 145-2013,hef should be taken as the effective anchoring depth stated in the anchor product manual. This is the most authoritative and accurate method for determining the value.

The Daring undercut anchor product specification table clearly lists for each model theeffective embedment depth hef:

Rod diameterProduct specificationDrilling diameter (mm)Effective embedment depth hef (mm)Drilling depth (mm)
M10M10/14×40144045
M12M12/18×60186070
M12M12/18×80188090
M12M12/18×10018100110
M16M16/22×10022100110
M16M16/22×12022120130
M20M20/28×16028160180

Source: Daring undercut anchor product specification table

Key notes:The drilling diameter of undercut anchors is much larger than that of ordinary expansion anchors. Taking the M12 undercut anchor as an example, the straight hole diameter must be drilled to18mm, and the straight-hole drill bit used is an M18 bit. The correct drilling diameter must be used during installation; otherwise an effective undercut interlock cannot be formed.

III. Code Detailing Requirements for hef

In addition to taking the value from the product manual, JGJ 145-2013 and GB 50367-2013 set minimum detailing requirements for hef:

3.1 Minimum anchorage depth

According to Clause 16.4.2 of GB 50367-2013, for anchors used in load-bearing structures, the anchorage depth hef determined by detailing requirementsshould not be less than 60mm nor less than the concrete cover thickness。

In addition, the minimum anchorage depth of undercut anchors differs across seismic fortification intensities:

  • Fortification intensity 6: minimum depth of4d(d is the nominal anchor diameter)

  • Fortification intensity 7: minimum depth of5d

  • Fortification intensity 8: minimum depth of6d

Taking the M12 undercut anchor as an example, in seismic fortification zone 8 the minimum anchorage depth hef should not be less than72mm6d (12 × 6 = 72mm). The Daring M12/18×80 product (hef = 80mm) meets this requirement.

3.2 Minimum base material thickness

According to Clause 7.1.1 of JGJ 145-2013, for undercut anchors (including post-installed undercut anchors), the concrete base material thickness hshould not be less than 2 times hef, and h should exceed 100mm。

Taking the Daring M12*80*130 product (hef = 80mm) as an example, the minimum base material thickness should be2×80=160mm, and it must exceed 100mm. If the base material is too thin, the anchor under tension may cause concrete cone failure or even penetrate the base material.

3.3 Special requirements for bridge load-bearing members

Stricter requirements apply to undercut anchors used for bridge load-bearing members. According to the standards, anchors for bridge load-bearing members should be undercut anchors with a mechanical interlock effect, andthe effective anchoring depth must not be less than 8.0d for anchors under tension。

Taking the M12 undercut anchor as an example, the minimum hef for bridge load-bearing members should be8×12=96mm8.0d. The Daring M12*100*150 product (hef = 100mm) meets this requirement.

IV. Relationship Between hef and Load Capacity

hef is the core parameter for calculating concrete cone failure load capacity. According to Clause 16.3.2 of GB 50367-2013, hef participates directly in the calculation formula for concrete cone failure load capacity.

The larger the hef, the higher the concrete cone failure load capacity. But it also means:

  • Greater drilling depth, increasing installation difficulty

  • Higher probability of hitting rebar(the deeper the drilling, the more likely rebar is encountered in the base material)

  • Higher base material thickness requirements(base material thickness must be ≥2hef)

Therefore, a larger hef is not always better. Provided the design load capacity and the code detailing requirements are met,the smallest feasible hef should be chosen, to reduce installation difficulty and cost.

V. Common Misconceptions

5.1 Misconception 1: Installing undercut anchors like expansion anchors

Undercut anchor installation requiressecondary reaming, which is the most fundamental difference between undercut anchors and expansion anchors. Undercut anchors use more generous material and better material quality than sleeve expansion anchors — taking the sleeve as an example, the wall thickness of a common M12 undercut anchor is close to3mm, while sleeve expansion anchors have onlya little over 1mm。

If the reaming step is skipped, the sleeve bottom of an undercut anchor can barely expand when driven in the un-reamed state, and the load capacity is mostly below20kN. In contrast, an undercut anchor whose sleeve bottom is fully expanded performs excellently, essentially reaching the ultimate load capacity of the anchor rod at standard embedment depth,with the ultimate load capacity of conventional Grade 5.8 undercut anchors reaching over 45kN。

and the load capacity without reaming can differ from that after secondary reaming by more than 3 times.During installation, strike with a driving sleeve using a hammer or rotary hammer until the anchor sleeve is fully expanded. To help installers accurately control the driving depth, the rod of the Daring undercut anchor has anembedment depth linemarking; drive until the embedment depth line is flush with the base material surface, indicating that the anchor is fully installed and the bottom has fully expanded.

5.2 Misconception 2: Blindly increasing hef

When the embedment depth of an M12 undercut anchor reaches 80mm, even with Grade 8.8 carbon steel, the pull-out test result is tensile failure of the rod. Further increasing the embedment depth does not raise load capacity (the anchor has already failed in tension); it only increases installation difficulty and the probability of hitting rebar.

The most commonly used undercut anchor model isM12*80*130M12×80×130 (M12 denotes the rod outer diameter, 80 the embedment depth, and 130 the overall length); this model is well balanced in all respects.

5.3 Misconception 3: Neglecting hole cleaning

Undercut anchors also requiresimple hole cleaning after drilling; simply ensure dust does not clog the hole and hinder subsequent anchor installation. Although repeated dust blowing as with chemical anchor installation is unnecessary, this step must not be skipped.

VI. Summary of Methods for Determining hef

StepOperationBasis
Step 1Consult the anchor product manual to obtain the stated hef valueGB 50367-2013, Clause 16.3.2
Step 2Check that hef satisfies the detailing requirements (≥60mm and ≥ the concrete cover thickness)GB 50367-2013, Clause 16.4.2
Step 3Check that the base material thickness satisfies h ≥ 2hef and h > 100mmJGJ 145-2013, Clause 7.1.1
Step 4Verify against the design load capacity whether a larger hef is neededJGJ 145-2013, Chapter 6
Step 5Check the minimum hef requirement corresponding to the seismic fortification intensityGB 50367-2013, Clause 16.4.3

VII. FAQs

Q1What is the difference between effective anchoring depth hef and drilling depth?
hef is the depth over which the anchor effectively transfers load, determined by the anchor product structure; drilling depth is the actual hole depth drilled during installation, usually 10-20mm greater than hef (to accommodate the undercut section and the installation allowance).
Q2Can hef be increased arbitrarily?
No. hef should be taken from the product manual and satisfy the detailing requirements of the standards. Blindly increasing hef not only fails to raise load capacity (the rod may already fail in tension) but also increases installation difficulty and the probability of hitting rebar.
Q3What is the minimum hef for undercut anchors?
According to GB 50367-2013, hef should not be less than 60mm nor less than the concrete cover thickness. In seismic fortification zone 8, the minimum hef for an M12 undercut anchor is 72mm.
Q4What if the base material is not thick enough?
According to JGJ 145-2013, the base material thickness h for undercut anchors should not be less than 2hef and h > 100mm. If the base material is too thin, an anchor specification with a smaller hef should be chosen, or structural reinforcement measures taken.
Q5What is the purpose of the embedment depth line on Daring undercut anchors?
The rod of the Daring undercut anchor carries an embedment depth line marking; during installation, strike with a driving sleeve using a hammer or rotary hammer until the embedment depth line is flush with the base material surface, indicating that the anchor is fully installed and the bottom has fully expanded. This design helps installers accurately control the driving depth and avoids anchoring quality problems caused by under- or over-driving.

Daring undercut anchors (die-undercut anchors, post-cut anchors) are made of carbon steel of Grade 5.8 or above or 304/316 stainless steel, paired with dedicated undercut drill bits and installation tools. The products are suitable for cracked and non-cracked concrete base materials from C20 to C60, offering vibration resistance, impact load resistance, and high load capacity; the built-in mechanical interlock effect reduces torque requirements, and variable anchorage depths and fixture thicknesses are supported. For help determining the effective anchoring depth of undercut anchors and selection advice on a specific project, please contact the Daring technical team.

References

Daring website — Undercut Anchor product page(product specifications and effective embedment depth hef parameter table)

Daring website — Reaming: the Key to Undercut Anchor Installation(importance of reaming and load behavior comparison)

Daring website — Common Misconceptions About Undercut Anchor Models(M12×80×125 as the most common model and embedment depth misconceptions)

GB 50367-2013 Design Code for Strengthening of Concrete Structures — Clauses 16.3.2, 16.4.2, and 16.4.3

JGJ 145-2013 Technical Specification for Post-Installed Fastenings in Concrete Structures — Clause 7.1.1 and Table 7.1.2

Technical Specification for Post-Installed Fastenings in Concrete Structures — definition of hef (depth of the expansion cone at the point of maximum squeeze against the hole wall)