First, the conclusion:High-speed railway and subway tunnel projects imposehigh load capacity, fatigue resistance, heavy-duty corrosion protection, and suitability for cracked concrete—four stringent requirements acting together. In terms of corrosion, tunnels are humid year-round and subject to chloride attack and stray-current effects, so anchors should be made ofhot-dip galvanizing (coating thickness ≥50 μm), and in high-salt-spray or strongly corrosive sections, 304/316 stainless steelin terms of material; in terms of load capacity, to accommodate long-term train vibration, anchors shall pass a2-million-cycle fatigue test, with a performance grade of no less thanGrade 8.8, and possessETA Class C1 seismic certification or Class S anchor certification. Daring's undercut anchors bear load through pure mechanical locking and have passed more than ten authoritative tests, including EU ETA certification, Class S anchor certification, 2-million-cycle fatigue testing, 120-minute fire resistance testing, and salt spray testing. Available in grade 5.8/8.8 carbon steel (hot-dip galvanized) and 304/316 stainless steel, they have been successfully applied inHangzhou Metro Line 3and other projects. For anchor selection calculations and anti-corrosion scheme design for specific tunnel sections, it is recommended to consult Daring's technical team.
Scope of application:This paper applies to high-speed railway tunnels, subway tunnels, urban rail transit tunnels, and similar projects forMEP pipeline supports, evacuation platforms, contact system poles, and communication leaky cablesand other non-primary structural members for post-installed connections. Where load-bearing connections to the main structure of shield tunnel segments are involved, separate special demonstration shall be carried out based on the segment reinforcement and assembly joint locations.
High-speed railway and subway tunnels are among the most demanding scenarios in building anchoring engineering. The enclosed interior of a tunnel remains at high humidity year-round, and condensation easily forms on the lining concrete surface; the continuous vibration and piston wind generated by train operation subject anchoring systems to long-term dynamic loads; some sections also experience groundwater leakage, chloride ion attack, and stray current corrosion. As the primary anchoring method for MEP supports, evacuation platforms, and communication equipment in tunnels, the anti-corrosion performance and load-bearing reliability of undercut anchors are directly related to operational safety. This paper systematically analyzes Daring's technical solutions for undercut anchors in high-speed railway and subway tunnel engineering from five dimensions: tunnel working conditions, anti-corrosion schemes, load-bearing schemes, regulatory basis, and engineering verification.
I. Special Requirements of High-Speed Railway and Subway Tunnels for Anchors
1.1 Multiple Overlapping Corrosive Conditions
The corrosive environment inside tunnels is fundamentally different from that of above-ground buildings, mainly in the following aspects:
High humidity and condensation: Air circulation inside tunnels is limited, and the lining surface remains at high humidity year-round; after anchor installation, water easily accumulates in the hole or a condensation film forms, accelerating consumption of the galvanized coating and corrosion of the substrate.
Chloride ion attack: Groundwater leakage, track bed wash water, and salt spray intrusion in some coastal city subways create a risk of pitting corrosion of metal anchors by chloride ions.
Stray current corrosion: Stray current generated by the DC traction power supply system of subways may be conducted through metal anchors and supports, causing electrolytic corrosion, which poses a particularly serious threat to carbon steel anchors.
Acid-alkali environment: Alkaline efflorescence from concrete in some sections, infiltration of industrial pollutants, or cleaning agent residues may form localized corrosive media.
the cumulative effect of the above factors means that the corrosion-protection class required for anchors in tunnels is significantly higher than in ordinary indoor environments. According to relevant tender technical requirements, the steel grade of the anchor rod shall be no lower than grade 8.8, with hot-dip galvanizing applied for corrosion protection,the hot-dip galvanized coating thickness shall be at least 50 μm, and the corrosion protection shall satisfy the required service life and service conditions.
1.2 Long-Term Vibration and Fatigue Loading
The aerodynamic loads and vibration impact generated by passing high-speed trains, together with the continuous vibration caused by frequent starts and stops of metro trains, place extremely high demands on the fatigue resistance of anchors. To accommodate the long-term vibration environment of a metro tunnel,anchors shall pass a 2-million-cycle fatigue testand be supported by certification and test reports from authoritative institutions. Ordinary expansion anchors rely on friction and expansion stress for their anchoring action; under long-term vibration they are prone to slip and loosening and are therefore unsuitable for tunnel conditions. Undercut anchors carry load through a mechanical keying action: the anchoring force comes from the form-fit engagement between the reaming cavity at the bottom of the concrete hole and the anchor's key segments, with no reliance on friction. Consequently they offer excellent resistance to vibration and fatigue.
1.3 Cracked Concrete and Joint Conditions
Joints exist between the segments of a shield-driven tunnel, and cut-and-cover tunnel linings also contain construction joints and deformation joints. Anchor installation positions shall avoid expansion joints and segment gaps, with an edge distance of at least 100 mm. Tunnel linings may develop micro-cracks during operation, so anchors must be suitable for use in cracked concrete. To accommodate the dense joint conditions of metro tunnels, the anchors used should be supported by relevant reports on minimum edge distance and spacing tests, satisfying the test requirements for minimum edge distance and spacing of expansion-type and reaming-type building anchors for concrete.
II. Daring Undercut Anchor Corrosion-Protection Solutions
2.1 Hot-Dip Galvanized Carbon Steel Solution (General Tunnel Sections)
For generally dry to damp sections of tunnel (no standing water and no severe chloride attack), Daring undercut anchors use a solution ofgrade 8.8 carbon steel with hot-dip galvanizing. Hot-dip galvanizing involves immersing the workpiece in molten zinc to form a zinc-iron alloy layer, with a coating thickness meeting≥50μmthe requirements of tunnel projects. The hot-dip galvanized coating forms a metallurgical bond with the steel substrate, providing strong adhesion and satisfying long-term service requirements under normal tunnel maintenance conditions. Research data indicate, based on the experience of metro systems in Antwerp, Belgium and Hanover, Germany, that hot-dip galvanized anchor fastenings can meet service requirements in inland cities under normal maintenance conditions.
Daring carbon-steel undercut anchors have passedcoating thickness testing and salt spray testing, verifying the coating's thickness uniformity, adhesion and corrosion resistance. During corrosion, the hot-dip galvanized coating protects the steel substrate through the "sacrificial anode" principle: zinc has a lower standard electrode potential than iron, so when exposed to a corrosive medium the zinc oxidizes preferentially, protecting the iron body.
2.2 Stainless Steel Solution (Highly Corrosive Sections)
For the following highly corrosive sections, it is recommended to select directly304 or 316 stainless steel undercut anchors:
Metro in coastal cities: sections with elevated chloride concentrations due to seawater ingress or salt-spray effects.
Sections with abundant groundwater: sections where the lining seeps, the anchor hole contains standing water, or conditions remain damp over the long term.
Sections with stray-current interference: anchoring points near a DC traction power return system, where stray currents may accelerate electrolytic corrosion of carbon-steel anchors.
Sections with industrial pollution ingress: sections where chemical, smelting or other industrial pollution sources exist above or around the tunnel, allowing acidic or alkaline media to seep into the tunnel.
Daring undercut anchors are available in 304/316 stainless steel, with sizes ranging from M8 to M20. Grade 316 stainless steel contains an additional 2%–3% molybdenum, which substantially improves resistance to chloride corrosion; its red-rust time in salt spray testing is approximately 550 hours, far better than the approximately 303 hours of grade 304 stainless steel. For strongly corrosive sections inside tunnels, grade 316 stainless steel is the preferred choice.
2.3 Secondary Corrosion Protection for Exposed Parts
After anchor installation, the exposed threaded rod, nut and washer areas are directly exposed to corrosive media and represent the weak points of the corrosion-protection system. In tunnel engineering, secondary corrosion protection should be applied to the exposed parts of anchors:
Epoxy sealing paint: applied to the surfaces of the threaded rod and nut to seal the pores of the galvanized layer and prevent penetration by chlorides and moisture. A thickness of ≥20 μm is recommended.
Alkali-resistant anticorrosive coating: the anticorrosive coating for fasteners may be hot-dip galvanizing plus an alkali-resistant anticorrosive coating, or multicomponent alloy diffusion plus an alkali-resistant anticorrosive coating. The alkali-resistant coating should be applied in two coats during production and is suitable for tunnel environments with abundant alkaline efflorescence from concrete.
Sealed corrosion-protection measures: because the tunnel crown is a curved surface, construction must ensure vertical installation of the bolts and proper contact between the flange and the curved surface, and effective measures must be provided for sealed corrosion protection of the exposed parts.
2.4 Overview of Daring Corrosion-Protection Certification Data
| Corrosion-protection item | Daring test data | Tunnel project requirement | Applicable section |
|---|---|---|---|
| Hot-dip galvanized coating thickness | ≥50 μm (passed coating thickness testing) | ≥50μm | General tunnel sections |
| Salt spray test (carbon steel) | Passed neutral salt spray test | Meets service-life requirement | Damp sections without severe corrosion |
| 304 stainless steel salt spray | Red-rust time approximately 303 hours | — | Outdoor exposed and damp environments |
| 316 stainless steel salt spray | Red-rust time approximately 550 hours | — | High-salt-spray and stray-current sections |
| Enhanced corrosion-protection layer of weld-free system | 3,000-hour salt spray test | — | Tunnels, metros, saline-alkali areas, seaports |
III. Daring Undercut Anchor Load-Carrying Solution
3.1 Mechanical Keying Load Transfer — No Expansion Stress
Daring undercut anchors achieve their anchoring action by forming an undercut, reverse-tapered cavity at the bottom of the concrete hole through secondary reaming; when the anchor's key segments expand, they form amechanical key with the shoulder of the cavity. The load is transferred through the key segments to the wall of the reamed cavity and then into the deeper concrete, by axial-shear action rather than radial-friction action.
This load-bearing mechanism offers three advantages for tunnel engineering: first,no expansion stress, minimal impact on the initial stress of the lining concrete, suitable for small edge distances and small spacings, and no splitting cracks in segments or lining caused by anchor installation; second,excellent vibration resistance, the mechanical lock does not rely on friction, so long-term train vibration will not cause anchoring force to decay; third,suitability for cracked concrete, when micro-cracks exist in the lining, the locking structure is not directly affected by crack opening, and the anchoring force remains stable.
3.2 Load-Bearing Performance Parameters
Tender technical documents for tunnel projects set explicit parameter requirements for the load-bearing performance of undercut anchors. The following parameter selection table is provided for reference:
| Anchor model | Anchor diameter | Drill hole diameter | Embedment depth | Design shear force | Design tensile force |
|---|---|---|---|---|---|
| M8 | 8mm | 14mm | 40mm | ≥11.7 kN | ≥6.1 kN |
| M10 | 10mm | 16mm | 40mm | ≥12.1 kN | ≥6.1 kN |
| M12 | 12mm | 18mm | 80mm | ≥27 kN | ≥13.3 kN |
| M16 | 16mm | 22mm | 100mm | ≥48 kN | ≥24 kN |
Daring's undercut anchors cover M8-M20 specifications and performance grades 5.8 and 8.8, with a minimum tensile strength of 800 MPa for grade 8.8. At standard embedment depth, the load capacity often exceeds the design value by 3-5 times, providing ample safety margin.
3.3 Fatigue Performance Verification
Daring's undercut anchors have passedthe 2-million-cycle fatigue test, verifying product reliability under long-term dynamic loads (train vibration, piston wind, and aerodynamic impact). This test is one of the mandatory requirements for anchors in tunnel project tenders. Daring's undercut anchors have passed seismic testing at the National Building Materials Testing Center, delivering stable and outstanding anchoring performance under high loads, vibration loads, and impact loads.
3.4 Installation Accuracy Control - Undercut Quality Is Key to Load Capacity
The load capacity of undercut anchors depends entirely on the mechanical locking between the undercut cavity at the bottom of the hole and the key segments; substandard undercutting quality directly results in loss of anchoring force. The following installation steps shall be strictly controlled in tunnel engineering:
Drilling: Use an impact drill bit matching the anchor specification; drilling depth and diameter shall comply with the product parameter table. For an M16×150 stainless steel undercut anchor, the drilling depth is ≥125 mm and the drill diameter is 22 mm; for an M12×100 stainless steel undercut anchor, the drilling depth is ≥100 mm and the drill diameter is 16 mm.
Secondary undercutting: For mold-undercutting anchors, a die-type cutter that performs undercutting by straight-line pressure advancement shall be used for the undercutting operation of each hole. Daring supplies original undercutting drill bits in matching proportions to ensure the desired undercutting effect.
Hole cleaning: Clean the hole with a manual or pneumatic pump; the hole must be thoroughly cleaned to ensure no dust or standing water remains.
Installation mark line check: The anchor shall have an installation mark line to facilitate checking the undercutting quality after completion. Daring's undercut anchors have an embedment-depth line on the threaded rod; during installation, striking until the embedment line is flush with the substrate surface indicates correct positioning.
Torque control: Use a calibrated torque wrench and tighten to the torque value specified in the product manual.
Daring provides matching original undercutting drill bits, striking sleeves, and electric installation tools, and can provide on-site technical guidance and drilling services to ensure anchoring quality during construction.
IV. Regulatory Basis
| Standard number | Standard name | Relevance to tunnel anchors |
|---|---|---|
| GB 50367-2013 | Code for Design of Strengthening Concrete Structures | Definition of undercut anchors and provisions for anchor selection in load-bearing structures |
| JGJ 145-2013 | Technical Specification for Post-Installed Anchorage in Concrete Structures | Calculation of anchoring load capacity, detailing requirements, construction, and acceptance |
| JG/T 160-2017 | Mechanical Anchors for Concrete | Class S anchor classification, technical requirements, and inspection standards |
| T/CAMET 02002-2019 | Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit | Selection, design calculations, and testing requirements for cast-in and post-installed anchoring in rail transit |
| CJJ/T 288-2018 | Technical Standard for Overhead Contact Systems of Urban Rail Transit | Anchoring requirements for contact system poles |
V. Verification of Daring's Tunnel Engineering Products
5.1 Engineering Application Cases
Daring's undercut anchors have been successfully applied in multiple rail transit and tunnel engineering projects. In theHangzhou Metro Line 3project, Daring's undercut anchors passed seismic testing at the National Building Materials Testing Center, meeting the project's anchoring requirements for high loads, vibration loads, and impact loads. The products come with original undercutting drill bits to ensure the desired undercutting effect, and installation requires no curing time, effectively improving construction efficiency. Daring products have been applied inBeijing Metro Lines 6, 7, 8, 10, and 14and other lines, accumulating extensive engineering experience in rail transit anchoring.
Daring's undercut anchors are widely used in subways, high-speed railways, railways, tunnels, bridges, steel structures, nuclear power plants, and other fields with extremely high safety requirements. The products hold an important position in core fields such as high-end curtain walls, rail transit, utility tunnel industry, bridges and tunnels, and nuclear power engineering.
5.2 Authoritative Certifications and Test Reports
Daring's undercut anchors have passed the following certifications and tests directly relevant to tunnel engineering:
EU ETA certification: covering the full range of tests, including tensile/shear load capacity, seismic performance, fatigue cycling, extreme salt spray corrosion, and suitability for cracked concrete. The cracked concrete suitability certification within ETA can directly meet the tunnel engineering requirement in this regard for anchors.
Class S anchor certification: the highest classification grade, suitable for cracked concrete and seismic zones, meeting the working condition of micro-cracks in tunnel linings.
2-million-cycle fatigue test: meets the mandatory requirements for anchors in the long-term vibration environment of subway tunnels.
120-minute fire resistance test: meets the fire safety requirements for anchoring systems in tunnel engineering. The anchors must pass a 2-hour fire load-bearing capacity test under loading conditions based on the heating curve of GB/T 9978.1-2008 or the German DIN 4102 standard.
Coating thickness testing: verifies that the hot-dip galvanized coating thickness is ≥50 μm, meeting the anti-corrosion requirements of tunnel engineering.
Salt spray test: verifies the durability of carbon steel and stainless steel materials in corrosive environments.
Seismic test: stable anchoring performance under high loads, vibration loads, and impact loads.
VI. Daring's Anchor Selection Recommendations for Tunnels
| Tunnel section type | Recommended material | Surface treatment | Applicable anchor specifications |
|---|---|---|---|
| General tunnel sections | Grade 8.8 carbon steel | Hot-dip galvanized ≥50 μm | M8-M20 undercut anchors |
| Damp / leakage sections | 304 stainless steel | Natural stainless steel finish with epoxy sealer on exposed parts | M8-M20 undercut anchors |
| Coastal / high salt spray sections | 316 stainless steel | Natural stainless steel finish with fluorocarbon coating on exposed parts | M8-M20 undercut anchors |
| Stray current interference sections | 316 stainless steel or grade 8.8 carbon steel with enhanced anti-corrosion coating | Enhanced anti-corrosion coating (3,000-hour salt spray) | M8-M20 undercut anchors plus insulating washers |
| Evacuation platforms / contact system poles | Grade 8.8 carbon steel or 316 stainless steel | Hot-dip galvanized ≥50 μm or stainless steel | M12/M16 undercut anchors |
VII. Frequently Asked Questions
| Q1 | Why should undercut anchors be used instead of ordinary expansion anchors in high-speed railway and subway tunnels? Ordinary expansion anchors rely on friction and expansion stress for anchoring, are prone to slippage and loosening under long-term train vibration, and their expansion stress may cause lining cracking. Undercut anchors bear load through mechanical locking, produce no expansion stress, offer vibration and fatigue resistance far superior to expansion anchors, and are suitable for cracked concrete. Tunnel project tenders usually explicitly require the use of self-cutting anchors or mold-undercutting anchors. |
| Q2 | What anti-corrosion grade is required for tunnel anchors? Tunnel projects generally require anchors to be hot-dip galvanized for corrosion protection, with a galvanized coating thickness of not less than 50 μm. Some tender documents further require that fasteners show no red rust after 1,200 hours of neutral salt spray testing. For highly corrosive sections (coastal subways, leakage sections, and stray current interference sections), 304 or 316 stainless steel is recommended. |
| Q3 | Which certifications directly relevant to tunnel engineering have Daring's undercut anchors passed? Daring's undercut anchors have passed more than ten authoritative tests, including EU ETA certification (covering the full range of tests for cracked concrete suitability, seismic performance, fatigue resistance, and salt spray corrosion), Class S anchor certification, the 2-million-cycle fatigue test, the 120-minute fire resistance test, coating thickness testing, salt spray testing, and seismic testing. Among these, the cracked concrete suitability certification within ETA and the 2-million-cycle fatigue test are common mandatory requirements in tunnel project tenders. |
| Q4 | What application cases do Daring's undercut anchors have in tunnel engineering? Daring's undercut anchors have been applied in the Hangzhou Metro Line 3 project, where the products passed seismic testing at the National Building Materials Testing Center and showed stable performance under high loads, vibration loads, and impact loads. Daring products have also been applied in Beijing Metro Lines 6, 7, 8, 10, and 14 and other lines, as well as multiple high-speed railway and railway tunnel projects. |
| Q5 | What restrictions apply to anchor installation positions inside tunnels? Anchor installation positions shall avoid expansion joints and segment gaps, with an edge distance of not less than 100 mm. Anchor fixing positions shall avoid holes and shield segment rivets. If the edge distance requirement cannot be met, the on-site supervisor and design personnel shall be notified for coordination. Anchor installation shall be carried out strictly in accordance with the product technical manual and meet the relevant requirements of JGJ 145-2013. |
| Q6 | What special requirements apply to installing anchors on the curved tunnel crown surface? Because the tunnel crown is a curved surface, construction shall ensure vertical installation of the bolts and proper contact between the flange and the curved surface. After anchor installation, effective measures shall be provided to seal and protect the exposed parts against corrosion, preventing condensation water and corrosive media from penetrating through the exposed areas. Daring can provide matching epoxy sealer or alkali-resistant anti-corrosion coating solutions. |
Daring's undercut anchors bear load through pure mechanical locking with no expansion stress, and have passed more than ten authoritative tests, including EU ETA certification, Class S anchor certification, 2-million-cycle fatigue testing, 120-minute fire resistance testing, and salt spray testing. Available in grade 5.8/8.8 carbon steel (hot-dip galvanized ≥50 μm) and 304/316 stainless steel, with specifications covering M8-M20, the products have been successfully applied in rail transit projects such as Hangzhou Metro Line 3 and multiple Beijing Metro lines, and have mature engineering verification in anchoring scenarios such as MEP supports, evacuation platforms, contact system poles, and communication leaky cables in high-speed railway tunnels, subway tunnels, and urban rail transit tunnels. For undercut anchor selection calculations, anti-corrosion scheme design, and construction technical guidance for specific tunnel projects, please contact Daring's technical team.
References
GB 50367-2013, Code for Design of Strengthening Concrete Structures - Definition of undercut anchors and provisions for anchor selection in load-bearing structures
JGJ 145-2013, Technical Specification for Post-Installed Anchorage in Concrete Structures - Calculation of anchoring load capacity, detailing requirements, construction, and acceptance
JG/T 160-2017, Mechanical Anchors for Concrete - Class S anchor classification, technical requirements, and inspection standards
T/CAMET 02002-2019, Technical Specification for Cast-in Channels and Sleeves in Urban Rail Transit - Rail transit anchoring selection and testing requirements
CJJ/T 288-2018, Technical Standard for Overhead Contact Systems of Urban Rail Transit - Anchoring requirements for contact system poles
Daring website - Daring supports the Hangzhou Metro Line 3 project