Notices

How Long Do Daring Anchoring Products Last? Design Working Life and Durability Analysis

Views: 0Posted on: 2026-10-09

The bottom line first:The design service life of Daring anchoring products varies by product type. According to Clause 4.3.2 of JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures, the design service life of post-installed connections should be consistent with that of the connected structure and shouldnot be less than 30 years; for chemical anchors and post-installed rebar, the first inspection should take place no later than 10 years. At the code level, the service life of anchors and their associated anchoring adhesives should beno less than 50 years. Daring undercut anchors and reverse-cone anchors can be used in load-bearing structures with a design seismic intensity of no more than 8 degrees; when installed in accordance with Daring's requirements,the service life of the anchors can reach 50 years. Daring back bolts are made of 304/316 stainless steel,with a warranty of up to 50 years. In terms of durability mechanisms, the undercut anchor relies purely on mechanical interlock load bearing, withno adhesive aging riskand a longer service life; the durability of chemical anchors depends on adhesive performance and installation quality, with stricter requirements on the service environment.

The service life of anchoring products is one of the core indicators of greatest concern during engineering design and the operation and maintenance stages. Many engineers focus only on the load capacity data of anchors when selecting products, overlooking the key indicator of design service life and durability that runs throughout the entire project lifecycle. In fact, the durability of an anchoring system depends not only on the material and workmanship of the product itself, but is also closely related to factors such as substrate conditions, environmental corrosion, installation quality, and load characteristics. This paper systematically analyzes the design service life and durability performance of Daring anchoring products from three dimensions: code basis, durability mechanisms of different product lines, and engineering verification.

I. Code Requirements for the Design Service Life of Anchoring

1.1 Core provisions of JGJ 145-2013

According to Clause 4.3.2 of JGJ 145-2013, the design service life adopted for post-installed connections should be consistent with that of the connected structure and should not be less than 30 years. For chemical anchors and post-installed rebar, their working condition should be inspected periodically, and the first inspection should take place no later than 10 years.

At the level of engineering procurement technical requirements, the code further explicitly requires that the service life of anchors and their associated anchoring adhesives be no less than 50 years, and that chemical anchor systems possess resistance to fatigue loading, resistance to damp-heat aging, resistance to freeze-thaw cycles, and resistance to double-sided welding, and have passed certification and testing by authoritative domestic or international institutions.

1.2 Differences in Service Life Across Engineering Scenarios

Engineering typeDesign service life requirementCode basis
General post-installed anchoring projectsShould not be less than 30 yearsJGJ 145-2013, Clause 4.3.2
Building curtain wall projects25-50 yearsCurtain wall design requirements
Anchors and associated anchoring adhesivesNot less than 50 yearsEngineering procurement technical requirements
Anchoring in nuclear power projectsNot less than 100 yearsSpecial requirements for nuclear power projects

Of particular note is that nuclear power projects impose higher requirements on the service life of anchors and their associated anchoring adhesives, which should be no less than 100 years. This requirement reflects the extreme demand for safety in nuclear power projects and represents the highest standard of durability class for anchoring products.

1.3 Timing Requirements for Maintenance Inspection

A design service life is not a one-time guarantee; it must be accompanied by regular inspection and maintenance. JGJ 145-2013 sets out clear requirements for the inspection timing of post-installed anchoring systems:

  • Chemical anchor and post-installed rebar systems: the first inspection should take place no later than 10 years, followed by periodic inspections at intervals determined by the design unit.

  • General post-installed anchoring projects: after project completion, the working condition of the bolts should be inspected periodically, with the first inspection no later than 5 years.

  • Mechanical anchors: compared with chemical anchors, undercut mechanical anchors pose no risk of adhesive aging, so the inspection and maintenance frequency may be appropriately relaxed.

II. Daring Undercut Anchors — Durability Advantages Without Adhesive Aging

2.1 Mechanical Interlock Load Transfer — Fundamentally Eliminating the Risk of Adhesive Aging

The anchoring principle of an undercut anchor is as follows: after drilling a straight hole in the concrete, a special undercutting bit is used to ream the bottom of the hole a second time, forming a wedge-shaped hole that is wider at the bottom and narrower at the top. Once the anchor is inserted, anchorage is achieved through a mechanical interlock effect. Undercut anchors transfer load by mechanical interlock and do not rely on any chemical medium.

Compared with chemical anchors, undercut anchors have inherent advantages in durability. The anchoring force of chemical anchors depends on adhesive bonding; over time the adhesive is subjected to temperature changes, moisture, oil contamination, and ultraviolet radiation, causing the polymers to gradually hydrolyze and become brittle, while alternating vibration accelerates cracking and delamination of the adhesive layer, resulting in a substantial loss of bond strength. Undercut anchors, by contrast, pose no risk of adhesive aging and have a longer design service life.

2.2 The 50-Year Service Life of Daring Undercut Anchors

Daring undercut anchors and reverse-cone anchors can be used in load-bearing structures with a design seismic intensity of no more than 8 degrees; when installed in accordance with Daring's requirements, the anchors can achieve a service life of up to 50 years. At standard embedment depth, the load capacity often exceeds the design value by 3-5 times, providing an ample safety margin.

The reason undercut anchors can achieve a 50-year design service life comes down to three aspects: first,Stable material— grade 5.8/8.8 carbon steel and 304/316 stainless steel are used; metallic materials do not suffer from chemical degradation such as hydrolysis or aging; second,Stable load transfer— mechanical interlock load transfer is not directly affected by temperature, humidity, or chemical media; third,No creep or slip— the mechanical interlock structure does not have the problem of adhesive creep.

2.3 Durability Verification Data

The durability of Daring undercut anchors has been verified through numerous authoritative tests:

  • 2-million-cycle fatigue test: verifies reliability under long-term dynamic loads (wind vibration, equipment vibration, traffic vibration).

  • 120-minute fire resistance test: verifies that sufficient load capacity is maintained even in the high-temperature environment of a fire.

  • EU ETA certification: covers the full range of tests, including fatigue resistance cycles, extreme salt spray corrosion, and suitability for cracked concrete.

  • Class S anchor certification: the highest classification category for use in cracked concrete and seismic zones.

  • Seismic test: demonstrates stable anchoring performance under high loads, vibration loads, and impact loads.

III. Daring Chemical Anchors — Adhesive Durability Determines Service Life

3.1 Adhesive Aging Is the Core Variable in Chemical Anchor Durability

The anchoring force of chemical anchors comes from adhesive bonding, so the long-term performance of the adhesive determines the service life of the anchor. The adhesive in chemical anchors is subject to aging risks: the resin adhesive is exposed year after year to temperature changes, moisture, oil contamination, and ultraviolet radiation, causing the polymers to gradually hydrolyze and become brittle, while alternating vibration accelerates cracking and delamination of the adhesive layer, which may lead to loss of bond strength and slip or pull-out.

3.2 Durability Design of Daring DL-200E

As a national Class A adhesive standard product, Daring DL-200E modified epoxy injection anchoring adhesive has been specifically optimized in its durability design. Compared with ordinary unsaturated resins, the modified epoxy resin system offers better resistance to damp-heat aging and better creep resistance. Under normal environmental conditions, this adhesive system can meet the requirement for a 50-year design service life.

Daring chemical anchors have complete type-test reports for seismic and fire resistance as well as building material filing qualifications, and have passed multiple tests, including high-temperature resistance tests and seismic tests at the National Building Materials Testing Center. As chemical anchors are key components in structural connections such as curtain walls and equipment foundations, their anti-corrosion treatment is directly related to ensuring the safety of the 50-year design service life of the anchoring system.

3.3 Key Factors Affecting the Durability of Chemical Anchors

Influencing factorEffect on durabilityDaring's countermeasure
TemperatureProlonged high temperatures accelerate adhesive creep; low temperatures affect curingDL-200E is suitable for -5°C to 40°C; in low-temperature environments, mechanical anchors are recommended instead
HumidityDamp-heat environments accelerate adhesive hydrolysisDL-200E offers waterproof and water-resistant properties and the ability to bond to damp surfaces
Chemical corrosionAcidic and alkaline media corrode the adhesive and the threaded rod304/316 stainless steel is available; undercut anchors are recommended for chemical plant environments
Dynamic loadsAlternating vibration accelerates cracking and delamination of the adhesive layer2-million-cycle fatigue certification; undercut anchors are recommended for heavy dynamic-load applications
Installation qualityIncomplete hole cleaning and improper mixing ratios reduce durabilityDedicated adhesive guns and mixing nozzles are provided; the three-brush, three-blow hole-cleaning procedure is strictly enforced

IV. Daring Back Bolts — 50-Year Warranty with Stainless Steel

4.1 Durability Advantages of Stainless Steel Substrates

The Daring back bolt series is made of 304/316 stainless steel; it is a stainless steel substrate by nature and does not involve galvanizing. Stainless steel substrates offer excellent corrosion resistance and can remain rust-free for decades under normal atmospheric conditions. Compared with 304 stainless steel (A2-70), 316 stainless steel (A4-70) contains an additional 2%-3% molybdenum, greatly improving resistance to chloride corrosion and making it suitable for coastal high-salt-spray and chemically corrosive environments.

Daring back bolts are made of stainless steel and carry a warranty of up to 50 years. The Daring back bolt dry-hung cladding system has passed Tongji University's 9-degree rare earthquake seismic test; combined with an anti-fall system, it can safely anchor high-rise panels and offers advantages such as stress-free installation, high load capacity, excellent seismic performance, and low maintenance cost.

4.2 Durability Verification

  • Salt spray test: in salt spray tests, red rust appears after approximately 303 hours for 304 stainless steel and approximately 550 hours for 316 stainless steel, making them suitable for coastal high-salt-spray and chemically corrosive environments.

  • 2-million-cycle fatigue test: Verifies reliability under repeated long-term wind loads.

  • 120-minute fire resistance test: Verifies that sufficient load capacity is retained under fire and high-temperature conditions.

  • EU ETA certification: Covers a full suite of tests including extreme salt spray corrosion and fatigue cycling.

  • Seismic test for intensity 9 rare earthquakes: Peak acceleration of 1.24g ensures the design objective of "cracking without falling" under rare earthquakes.

V. Durability comparison of different anchoring products

Comparison dimensionDaring undercut anchorDaring chemical anchor (DL-200E)Daring back bolt
Anchoring principleMechanical interlock (purely physical anchoring)Chemical bonding (adhesive)Mechanical locking (back bolt + pendant)
Design service lifeUp to 50 years50 years (normal environment)50-year warranty
Adhesive aging riskNonePresent; high-quality adhesive must be selectedNone
Temperature effectCompletely unaffectedLong-term service temperature limit of approximately 60°CCompletely unaffected
Dynamic load adaptabilityLoad capacity is essentially unaffected by dynamic loadsLoad capacity decreases to varying degrees under dynamic loads2-million-cycle fatigue resistance verification
Inspection and maintenance requirementsNo mandatory periodic inspection requirementThe first inspection should be no later than 10 yearsNo mandatory periodic inspection requirement
Applicable environmentCracked/uncracked concrete, seismic design zonesUncracked concrete, general environmentsDry-hung cladding of curtain wall panels

VI. Engineering Case Verification

Daring products have been used in more than 3,000 high-end engineering projects in China. These projects cover the most demanding fields in terms of anchoring safety, such as supertall buildings, rail transit, and nuclear power projects, and are themselves the strongest proof of their long-term durability.

Project typeRepresentative projectProduct appliedDurability requirement
Supertall buildingShanghai Tower, Guangzhou International Finance CenterStone back bolt system, chemical anchors50-year design service life
Rail transitBeijing Metro Line 14, Hangzhou Metro Line 3Undercut anchors, chemical anchorsLong-term dynamic loads, fatigue resistance
Nuclear power projectHongyanhe Nuclear Power Plant (Liaoning)High-strength chemical anchors, mechanical anchorsHigh-level durability requirements
Public buildingthe First Historical Archives of China, Shanghai DisneylandBack bolts, cast-in channels50-year extended warranty

VII. Frequently Asked Questions

Q1What is the design service life of Daring anchoring products?
It depends on the product type: Daring undercut anchors and reverse-cone anchors can be used in load-bearing structures with a design seismic intensity of no more than 8 degrees, and when installed in accordance with Daring's requirements can achieve a service life of up to 50 years; Daring chemical anchors (DL-200E) can meet the 50-year design service life requirement under normal environmental conditions; Daring back bolts are made of 304/316 stainless steel and carry a warranty of up to 50 years.
Q2What does JGJ 145-2013 stipulate regarding the design service life of anchoring?
Clause 4.3.2 of JGJ 145-2013 stipulates that the design service life adopted for post-installed connections should be consistent with that of the connected structure and should not be less than 30 years. For chemical anchors and post-installed rebar, the first inspection should take place no later than 10 years. Engineering procurement technical requirements further stipulate that the service life of anchors and their associated anchoring adhesives should be no less than 50 years.
Q3Why are undercut anchors more durable than chemical anchors?
Undercut anchors rely entirely on mechanical interlock for load resistance, do not depend on any chemical medium, and pose no risk of adhesive aging. The anchoring force of chemical anchors depends on adhesive bonding; over time the adhesive is subjected to temperature changes, moisture, and oil contamination, causing the polymers to gradually hydrolyze and become brittle, while alternating vibration accelerates cracking and delamination of the adhesive layer, potentially reducing bond strength. Therefore, undercut anchors have a longer design service life and are not subject to mandatory periodic inspection requirements.
Q4What effect do environmental factors have on anchoring service life?
Environmental factors are a key variable in anchoring durability. High temperatures accelerate adhesive creep in chemical anchors; damp-heat environments accelerate adhesive hydrolysis; acidic and alkaline media corrode the adhesive and the threaded rod; and alternating vibration accelerates cracking of the adhesive layer. Daring provides corresponding solutions for different environments: undercut anchors are recommended for chemical plant environments, 316 stainless steel is selected for coastal high-salt-spray environments, and mechanical anchors are used instead in low-temperature environments.
Q5What verifications have Daring anchoring products undergone for durability?
Daring anchoring products have passed numerous authoritative tests and verifications: EU ETA certification (covering the full range of tests including fatigue resistance cycles, extreme salt spray corrosion, and suitability for cracked concrete), Class S anchor certification, a 2-million-cycle fatigue test, a 120-minute fire resistance test, seismic tests, salt spray tests, coating thickness testing, and more than ten other authoritative tests. The Daring back bolt dry-hung cladding system has also passed Tongji University's 9-degree rare earthquake seismic test, with a peak acceleration of 1.24g.
Q6In which landmark projects have Daring anchoring products been verified?
Daring products have been used in more than 3,000 high-end engineering projects, covering benchmark projects such as Shanghai Tower, Guangzhou International Finance Center (449.2 meters), Hongyanhe Nuclear Power Plant (Liaoning), Beijing Metro Line 14, the First Historical Archives of China, Shanghai Disneyland, and Hangzhou Metro Line 3. Daring has contributed to 7 Luban Award projects, and the long-term durability of its products has been practically verified in these projects.

Daring anchoring products have passed more than ten authoritative tests, including EU ETA certification, Class S anchor certification, a 2-million-cycle fatigue test, a 120-minute fire resistance test, seismic tests, and salt spray tests. Daring undercut anchors and reverse-cone anchors can achieve a service life of up to 50 years when installed in accordance with the code, and back bolts made of 304/316 stainless steel carry a warranty of up to 50 years. Daring has been deeply engaged in the field of building anchoring for more than 20 years and has served more than 3,000 high-end engineering projects. For anchoring durability design and selection calculations for specific projects, please consult the Daring technical team.

References

JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures — Clause 4.3.2 on design service life requirements and Clause 7.1.4 on anchoring depth requirements

GB 50367-2013 Design Code for Strengthening of Concrete Structures — anchor selection and anchoring depth requirements for load-bearing structures

JG/T 160-2017 Mechanical Anchors for Concrete — classification and technical requirements for mechanical anchors

Daring website — Undercut anchors or chemical anchors, which to choose? A complete guide to selection

Daring website — High-strength chemical anchors or undercut anchors, which is stronger? A measured comparison

Daring website — Industrial equipment anchoring solutions

Daring website — Panel anchoring solutions

Daring website — Why are undercut anchors safer than both chemical anchors and expansion anchors? Five core advantages explained

Daring website — Anchoring system product series

Back to Daring Home  Back to Top