Undercut anchors or chemical anchors — which one should you choose? Key selection points explained in one article

Views: 0Posted on: 2026-09-14

The short answer:There is no absolute answer as to which is better, undercut anchors or chemical anchors;the key is the application scenario. In terms of cost-effectiveness, ordinary chemical anchors are more affordable, with an overall cost of about half that of undercut anchors; however, in terms of long-term reliability and safety, undercut anchorsoffer more stable seismic performance, are suitable for cracked concrete, carry no risk of adhesive aging, and lock immediately upon installation with no need to wait for curing. At the code level,load-bearing structures must use undercut anchors or special reverse-cone chemical anchors, and ordinary chemical anchors are strictly prohibited in load-bearing structures and cracked concrete. For load-bearing applications such as curtain walls, steel structures, rail transit, and heavy equipment, undercut anchors are the first choice; for general fixing in non-load-bearing, non-cracked concrete, ordinary chemical anchors offer a cost advantage. Daring offers a full range of both undercut anchors and chemical anchors and can provide customized selection recommendations for different working conditions.

In post-installed anchoring construction, undercut anchors and chemical anchors are the two most commonly used anchoring products. Many designers and purchasers face the same dilemma: which one is more suitable? Based on code requirements and measured data, this article systematically compares the two across dimensions including working principle, load capacity, seismic performance, installation conditions, durability, and applicable scenarios, to help engineers make an informed selection.

I. Basic understanding of undercut anchors and chemical anchors

1.1 Undercut anchors

Undercut anchors, also known as mold-undercut anchors or post-cut undercut anchors, belong to the category ofundercut mechanical anchors. Their working principle is: after drilling a straight hole in the concrete, a special undercutting drill bit is used at the bottom of the hole to carry outsecondary reaming, forming a wedge-shaped hole that is wider at the bottom and narrower at the top; once the anchor is inserted,a mechanical keying effectcreates the anchoring. The load-bearing mechanism of undercut anchors ismechanical keying and does not rely on any chemical medium.

Depending on their construction, undercut anchors are further divided intoself-undercutting, mold-undercutting, and adhesive-mold-undercuttingthree types. Daring undercut anchors are made of carbon steel of grade 5.8 or above or 304/316 stainless steel and comply with the requirements of JGJ 145-2013.

1.2 Chemical anchors

A chemical anchor is an anchoring product composed of a metal threaded rod and anchoring adhesive, which creates the anchoring effect. According to JGJ 145-2013, chemical anchors are divided intoordinary chemical anchorsandspecial reverse-cone chemical anchorstwo categories. Ordinary chemical anchors are used with chemical capsules (glass tubes) and are suitable only for non-cracked concrete; special reverse-cone chemical anchors are used with injection anchoring adhesive and are suitable for both cracked and non-cracked concrete.

An ordinary chemical anchor (high-strength chemical anchor) consists of a metal threaded rod and a chemical agent (resin adhesive) sealed in a glass tube. During installation, the glass tube is broken by rotating the threaded rod, allowing the chemical agent to mix and fill the space between the rod and the concrete hole wall, and anchoring is achieved throughthe bonding action of the adhesive. High-strength chemical anchors rely entirely on adhesive bonding for load-bearing and are chemical-bonding anchors.

II. Undercut anchors vs. chemical anchors: A comprehensive comparison across seven dimensions

Comparison dimensionUndercut anchorOrdinary chemical anchorSpecial reverse-cone chemical anchor
Anchoring principleMechanical keying (interlock by reaming at the hole bottom)Chemical bonding (adhesive)Dual load-bearing by chemical bonding and mechanical keying
Ultimate load capacity (M12, grade 8.8)67.4 kN67.4 kNDepends on product certification
Suitability for cracked concreteSuitableStrictly prohibitedSuitable
Suitability for load-bearing structuresMandatory requirementStrictly prohibitedSuitable(mandated by code)
Seismic performanceLoad capacity essentially unaffected by dynamic loadsLoad capacity decreases to varying degrees under dynamic loadsRelatively good seismic performance
Load-bearing after installationReady for immediate use, no curing requiredRequires waiting for the adhesive to cureRequires waiting for the adhesive to cure
Temperature effectsCompletely unaffectedWill not cure below -5°CCan be installed above -5°C (low-temperature type)
Long-term durabilityNo risk of adhesive aging, long service lifeThe adhesive is subject to agingThe adhesive is subject to aging

III. In-depth analysis of the core differences

3.1 Load-bearing principle: Keying vs. bonding - The fundamental difference

The most fundamental difference between the two types of anchors lies in theirload-bearing principle. Ordinary chemical anchors rely on thebonding force of the adhesiveto bond the anchor to the hole wall, which is akin to gluing. If the adhesive ages or the base material cracks, the bonding force drops significantly and the risk of anchoring failure is high.

Undercut anchors are completely different. They usepre-reaming at the bottom of the hole, so that the keys at the bottom of the anchor expand and form amechanical interlockwith the reamed cavity, and the load-bearing behavior is similar to that of a cast-in foundation bolt. This keying structuredoes not rely on friction and can maintain stable anchoring force even if the base material cracks. Figuratively speaking, an ordinary chemical anchor is glued in place, while an undercut anchor is locked in place.

3.2 Load capacity: Essentially the same at the same grade

The ultimate tensile capacity of an anchor is determined mainly by the steel material and the effective cross-sectional area. When the embedment depth and the strength of the concrete base material are sufficient, both high-strength chemical anchors and undercut anchors may fail bytensile rupture of the anchor steel, in which case the ultimate load capacity of both is determined by the strength of the threaded rod itself.

Taking M12, grade 8.8 products as an example, the average tensile failure load of both high-strength chemical anchors and undercut anchors is67.4kN, and the design tensile load for both is51.8kN. Under the premise of standard embedment depth and qualified workmanship, the ultimate load capacities of the two are essentially the same. It should be noted, however, that products of different strength grades differ significantly in load capacity. Taking M12 anchors as an example, the average tensile failure load for grade 5.8 is about42.2kN, while grade 8.8 can reach67.4kN. The appropriate strength grade should be selected according to the design load requirements.

3.3 Seismic performance: Undercut anchors have a clear advantage

Under dynamic loads, expansion anchorsexperience varying degrees of reduction in ultimate load capacity, and are prone toslipping or even pulling out under fatigue loads and vibration. This is one of the biggest hidden dangers of expansion anchors.

The ultimate load capacity of undercut anchorsis essentially unaffected by dynamic loading. Daring undercut anchors have passedseismic tests at a building materials testing center, and the products have excellent seismic performance. By creating a load-bearing state similar to that of a cast-in insert, undercut anchors aim foran anchoring effect infinitely close to that of a cast-in insert.

3.4 Installation conditions: Undercut anchors are ready for immediate use

Ordinary chemical anchors use chemical capsules with short curing times - at room temperature, about20-30 minutesto cure. However, the curing of chemical anchors is greatly affected by temperature: 1-3 hours at 0-10°C, 5-12 hours at -5-0°C, and below -5°C theywill not cure。

After installation, undercut anchorsare ready for immediate use, with no need to wait for curing and can carry load as soon as installation is complete. Whether the ambient temperature is 30°C or -40°C, the installation and load-bearing capacity of undercut anchors arecompletely unaffected. They are especially suitable for projects with tight schedules and for winter construction.

3.5 Durability: Undercut anchors carry no risk of adhesive aging

The adhesive of chemical anchors is subject toaging risk, and their long-term stability is inferior to that of mechanical anchors. Especially in harsh environments involving high temperatures, high humidity, and freeze-thaw cycles, adhesive performance may deteriorate over time.

Undercut anchorscarry no risk of adhesive aging and have a long service life. At standard embedment depths, the load capacity of Daring undercut anchors often exceeds the design value by3-5 times, providing an ample safety margin. When installed in accordance with code requirements, the anchorscan achieve a service life of up to 50 years。

3.6 Failure mode: Ductile failure vs. brittle failure

The failure mode of undercut anchors isanchor tensile rupture - aductile failure, with obvious deformation warning before failure. The failure mode of ordinary chemical anchors isanchor pull-out or adhesive debonding - abrittle failure, with instantaneous release and no warning. A failure mode with warning gives engineers time to react and is therefore safer.

IV. Code requirements: Mandatory provisions for load-bearing structure selection

4.1 Provisions for anchor selection in load-bearing structures

According to Article 16.1.3 of GB 50367-2013 (Design Code for Strengthening Concrete Structures),mechanical anchors used in load-bearing structures shall be undercut anchors with a keying effect. Depending on their construction, these anchors are further divided into three types: self-undercutting, mold-undercutting, and adhesive-mold-undercutting;adhesive anchors used in load-bearing structures shall be special reverse-cone adhesive anchors。

According to Article 16.1.5 of GB 50367-2013,when anchors are used in load-bearing structures in seismic fortification zones, undercut anchors or special reverse-cone adhesive anchors shall be used, and they are permitted only in buildings with a fortification intensity of no more than 8 degrees and located on Class I or Class II sites.

According to Article 16.1.7 of GB 50367-2013,the design calculation of anchor connections in load-bearing structures shall be based on the assumption of cracked concrete; no increase in load capacity due to non-cracked concrete may be taken into account. This means that anchor products suitable for cracked concrete must be selected for load-bearing structures.

4.2 Scenarios in which ordinary chemical anchors and expansion anchors are strictly prohibited

Connections of load-bearing structural members (such as new beams, columns, corbels, etc.)Ordinary expansion mechanical anchors are strictly prohibited, and ordinary chemical anchors are strictly prohibited(i.e., not special reverse-cone). When anchors are used in load-bearing structures, the code requires design calculations to be based on the cracked concrete assumption, even if the original structure is not cracked. The selected anchor products must have passed certification testing for cracked concrete.

Both mechanical anchors and special reverse-cone chemical anchors have products suitable for cracked concrete, whereasordinary chemical anchors and ordinary expansion anchors cannot be used in such cases. In structures located in seismic fortification zones and in members directly subjected to dynamic loads,expansion anchors shall not be used as connections in load-bearing structures.

V. Selection decision guide

5.1 Quick reference table for selection decisions

Working conditionRecommended anchorStrictly prohibited
Non-load-bearing + non-cracked concreteOrdinary chemical anchors, expansion anchors—
Non-load-bearing + cracked concreteUndercut anchors, special reverse-cone chemical anchorsOrdinary chemical anchors, expansion anchors
Load-bearing + non-cracked concreteUndercut anchors, special reverse-cone chemical anchorsOrdinary chemical anchors, expansion anchors
Load-bearing + cracked concreteMust useUndercut anchors or special reverse-cone chemical anchorsOrdinary chemical anchors, expansion anchors
Seismic fortification zone + load-bearingMust useUndercut anchors or special reverse-cone chemical anchorsExpansion anchors, ordinary chemical anchors
Tight schedule / winter constructionUndercut anchors (ready for immediate use, unaffected by temperature)Ordinary chemical anchors (require waiting for curing)
Cost-sensitive non-load-bearing projectsOrdinary chemical anchors—

5.2 Core selection principles

  • Load-bearing structures: Undercut anchors or special reverse-cone chemical anchors must be selected; ordinary chemical anchors are strictly prohibited

  • Cracked concrete: Undercut anchors or special reverse-cone chemical anchors must be selected

  • Seismic fortification zones: Undercut anchors or special reverse-cone chemical anchors must be selected, and the fortification intensity must not exceed 8 degrees

  • Tight schedules or winter construction: Undercut anchors are preferred, as they are ready for immediate use and unaffected by temperature

  • General fixing in non-load-bearing, non-cracked concrete: Ordinary chemical anchors offer better cost-effectiveness

VI. Daring anchoring solutions

6.1 Daring undercut anchors

Daring undercut anchors employ adeep mechanical keyingdesign; secondary reaming creates a reverse-cone cavity at the bottom of the drilled hole, and the expansion segments at the anchor base open up to form a rigid mechanical key with the deep concrete. All loads are concentrated and transferred to the dense, deep concrete at the hole bottom,with no shallow expansion stress. The products have passedClass S anchor certification, 2 million fatigue cycles, 120 minutes of fire resistance, and seismic tests and many other tests.

The Daring undercut anchor series coversM8-M20 specifications, with materials including grade 5.8 and grade 8.8 carbon steel (hot-dip galvanized ≥45 μm) and 304/316 stainless steel, and supplied withoriginal manufacturer undercutting drill bits and electric installation tools, to ensure reaming quality. The products comply with JGJ 145-2013, GB 50367-2013, and other code requirements.

6.2 Daring chemical anchors

The Daring chemical anchor series covershigh-strength chemical anchors, capsule chemical anchors (special reverse-cone), and dynamic-load reverse-cone chemical anchors and other categories, combined with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Class A adhesive standard. Carbon steel of grade 5.8 or above or 304/316 stainless steel is available. Daring high-strength chemical anchors are supplied with chemical capsules that cure rapidly in 30 minutes at room temperature, with a pull-out force of up to 60 kN for M12. Daring capsule chemical anchors feature a reverse-cone structural design and a dual load-bearing mechanism of chemical bonding plus mechanical keying. They have passed Class S anchor certification, 2 million fatigue cycles, 120 minutes of fire resistance, seismic tests, and many other tests, and are suitable for both cracked and non-cracked concrete.

6.3 Daring's full product line

Daring's mechanical anchor series covers undercut, self-undercutting, drop-in, Anka, and heavy-duty mechanical anchors, among other categories. Made of carbon steel or stainless steel with multiple coating options, they achieve, through mechanical locking,immediate locking upon installation with no curing required, high load capacity, and seismic and fatigue resistance. They are compatible with a variety of base materials, including cracked/non-cracked concrete and natural stone, and are widely used in curtain walls, steel structures, heavy equipment, rail transit, and tunnel and utility tunnel anchoring applications. For anchor selection recommendations for specific projects, please consult the Daring technical team.

VII. Frequently asked questions

Q1Which is stronger, an undercut anchor or a chemical anchor?
At the same specification, the ultimate load capacities are essentially the same. Taking M12, grade 8.8 as an example, the average tensile failure load of both is 67.4 kN. However, undercut anchors offer more stable seismic performance, are suitable for cracked concrete, and carry no risk of adhesive aging, giving them better long-term reliability.
Q2Which type of anchor should be selected for load-bearing structures?
According to GB 50367-2013, mechanical anchors used in load-bearing structures shall be undercut anchors with a keying effect, and adhesive anchors used in load-bearing structures shall be special reverse-cone adhesive anchors. Ordinary chemical anchors are strictly prohibited in load-bearing structures.
Q3Which type of anchor should be selected for cracked concrete?
In cracked concrete, undercut mechanical anchors or special reverse-cone chemical anchors must be used. Ordinary chemical anchors are strictly prohibited in cracked concrete. Undercut anchors are the type of mechanical anchor mandated by GB 50367-2013 for load-bearing structures.
Q4Which should be chosen for tight schedules or winter construction?
Undercut anchors are recommended. They lock immediately upon installation, require no curing, and are completely unaffected by temperature - they are ready for immediate use even at -40°C. The curing time of chemical anchors is greatly extended at low temperatures, and they will not cure below -5°C.
Q5What anchor products does Daring offer?
Daring offers a full range of both undercut anchors and chemical anchors. Daring undercut anchors have passed Class S anchor certification, 2 million fatigue cycles, 120 minutes of fire resistance, seismic tests, and many other tests. The Daring chemical anchor series covers high-strength, capsule-type, special reverse-cone, and dynamic-load reverse-cone anchors, combined with DL-200E modified epoxy injection anchoring adhesive.

Daring offers a full range of both undercut anchors and chemical anchors, covering mechanical anchors (undercut, self-undercutting, drop-in, Anka, and heavy-duty mechanical anchors) and chemical anchors (high-strength, capsule-type, special reverse-cone, and dynamic-load reverse-cone). Daring undercut anchors achieve mechanical locking, are ready for immediate use without curing, and have passed ETA certification, Class S anchor certification, 2 million fatigue cycles, 120 minutes of fire resistance, seismic tests, and many other tests. For anchor selection recommendations for specific projects, please consult the Daring technical team.

References

JGJ 145-2013 Technical Specification for Post-Installed Anchoring of Concrete Structures - Anchor classification, selection, and installation requirements

GB 50367-2013 Design Code for Strengthening Concrete Structures - Provisions for anchor selection in load-bearing structures

Daring website - Which is stronger, a high-strength chemical anchor or an undercut anchor? A measured comparison

Daring website - What are the differences between expansion anchors and undercut anchors? A complete guide to selection

Daring website - Undercut mechanical anchor product page

Daring website - Chemical anchor product series

Back to Daring Home  Back to Top