The conclusion first:Selecting back bolts for super high-rise building curtain walls requires comprehensive consideration ofwind loads, seismic fortification, panel thickness, and the corrosive environmentas the four core factors. In terms of wind loads, the basic wind pressure of super high-rise buildings is typically ≥ 0.55kN/m², and the standard value of wind load must be determined through wind tunnel testing; in terms of seismic performance, the back bolt system should meet the9-degree rare earthquake requirement, with an acceleration of not less than 1.24g. For panels ≤ 20mm thick, preferentially choose thescrew-in back bolt (no impact stress); for panels ≥ 25mm thick, thehammer-in back bolt(high load capacity and large hole tolerance). In terms of materials, general environments call for304 stainless steel (A2-70), while coastal high salt-spray environments require316 stainless steel (A4-70/A4-80). Daring back bolt dry-hung systems have fully passedTongji University's 9-degree rare earthquake seismic test, with acceleration reaching 1.24g, making them especially suitable for curtain wall projects involving super-tall buildings, high seismic requirements and harsh environments.

As urban buildings continue to rise ever higher, the wind loads and seismic actions faced by super-tall building curtain walls are becoming increasingly severe. As the core connectors between curtain wall panels and the main structure, the selection of back bolts directly affects the safety of the entire building. Many designers and engineers lack a systematic understanding of the key points for selecting back bolts for super-tall curtain walls. This article provides a comprehensive analysis from the perspectives of wind load effects, seismic requirements, comparison of back bolt types, material selection and selection decisions.

I. Core challenges facing super-tall curtain walls

1.1 Wind loads—the first test for super high-rise curtain walls

Wind loads on super high-rise buildings are far greater than on ordinary buildings. As building height increases, wind speed grows exponentially and wind pressure rises sharply. According to JGJ 102-2003 Technical Specification for Glass Curtain Wall Engineering, the basic wind pressure is calculated to a 50-year return period standard, and super high-rise buildings must undergo wind tunnel testingfor verification.

In actual projects, the basic wind pressure of super high-rise curtain walls is typically ≥ 0.55kN/m², and on some coastal super high-rise projects the wind pressure can reach 1.2-1.5kN/m². Under wind loads or seismic action perpendicular to the panel surface, the flexural design of panels supported by back bolt connections and the tensile design of the back bolt connections should preferably be analyzed and calculated using the finite element method。

Taking a super high-rise financial center as an example, the design tensile load capacity of the back bolts is ≥ 12.5kN, the maximum stress in the stone is kept within 8.0MPa (safety factor ≥ 2.5). The design tensile load capacity of a single bolt usually needs to reach 2.6-12.5kNdifferent values, depending on panel dimensions, wind loads, and seismic fortification requirements.

1.2 Seismic requirements: 9-degree rare earthquake resistance is a hard requirement

When super high-rise buildings are located in high seismic intensity zones, the seismic performance of the curtain wall system is critical. According to JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures, the design of post-installed anchoring connections should consider the combined influence of factors such as load type and the safety class of the anchoring connection.

The code requires the curtain wall to accommodate the inter-story displacement of the main structure under seismic action (1/100~1/70); tests have proven that back bolt connections can withstand a drift angle of 1/70 without damage. The back bolt system should meet the 9-degree rare earthquake requirement, with an acceleration of not less than 1.24g。

According to seismic test results, granite point-supported curtain walls with undercut back bolts may use single-cutting-plane back bolts without nylon plastic sleeves within the application range specified by the code (intensity zones 6-8); when used in intensity zones of 9 and above, a double-cutting-plane back bolt with nylon plastic sleeves。

2. Comparison of back bolt types and selection basis

2.1 Screw-in back bolts—the first choice for thin panels

The screw-in back bolt works by rotating the threaded rod to slowly expand the expansion sleeve, so during installation there is no impact stress, making it very friendly to panels. The screw-in back bolt features installation on panels as thin as 12mm, and is especially suitable for thin ceramic panels, sintered stone, and stone less than 20mm thick.

Core advantages:

  • Minimal installation stress, suitable for brittle thin panels

  • Precisely controllable expansion with consistent anchoring depth

  • Compatible with concave ear-type pendants, H-type pendants, and more

Applications: sintered stone (≥ 12mm), ceramic panels (≥ 12mm), thin granite (≤ 20mm)

2.2 Hammer-in back bolts—the preferred choice for thick panels and high-load applications

The hammer-in back bolt is installed by hammering with a mallet, using the wedge-shaped slope at the front of the threaded rod to spread the expansion part and form a friction lock with the inner wall of the back bolt hole. Daring hammer-in back bolts have fully passed the 9-degree rare earthquake test at Tongji University, reaching an acceleration of 1.24g, with excellent seismic performance.

Core advantages:

  • Large hole tolerance, with the safety factor increased over screw-in back bolts by 80%

  • Extremely strong single-point load capacity and the highest versatility

  • High installation efficiency, with a market share of over 80%

Applications: granite (≥ 25mm), marble (≥ 25mm), thick engineered panels

2.3 Back bolt type selection decision table

Panel thicknessRecommended back bolt typeRecommended specificationApplications
12-20mmScrew-in back boltM6×7~M6×12Thin granite, ceramic panels
20-25mmScrew-in or hammer-inM6×12~M8×15Medium-thickness stone
≥25mmHammer-in back boltM6×15/M8×15Thick granite, marble

Note: The anchoring depth of the back bolt should be 1/2 to 2/3 of the panel thickness, and the remaining thickness from the bottom of a double-cutting-plane back bolt hole to the panel face should not be less than 6mm. For thick stone over 35mm, an M8 back bolt。

3. Material selection: 304 vs 316 stainless steel

3.1 304 stainless steel (A2-70)

304 stainless steel is the most commonly used austenitic stainless steel, containing about 18% chromium and 8% nickel, with corrosion protection provided by a dense chromium oxide passivation film on the surface. Daring back bolt products are available in A2 (304) and A4 (316), two stainless steel material options.

Suitable environments: general indoor and outdoor environments, ordinary inland areas, non-corrosive environments

3.2 316 stainless steel (A4-70/A4-80)

Compared with 304 stainless steel, 316 stainless steel additionally contains 2%~3% molybdenum, which greatly improves resistance to chloride corrosion. 316 stainless steel is more durable than 304 stainless steel, with a pitting resistance equivalent (PREN value) ≥ 24, making it especially suitable for corrosive environments such as coastal areas, high salt spray, and industrial pollution.

Suitable environments: coastal high salt-spray environments, chemical corrosion environments, chloride-containing environments and super-tall building curtain walls (exposed outdoors over the long term)

3.3 Material selection recommendations

Designers should select the appropriate back bolt material based on theenvironmental corrosion classof the project location:

  • General inland cities: 304 stainless steel is sufficient

  • Coastal cities (within 5km of the coastline): must use316 stainless steel

  • Industrial pollution areas and high-pH environments: must use316 stainless steel

  • Super-tall buildings (height greater than 100m): 316 stainless steel is recommended to ensure long-term durability

IV. Decision guide for back bolt selection in super-tall building curtain walls

4.1 Key selection points under wind load conditions

Wind loads on super-tall buildings increase with height, so the following should be noted when selecting back bolts:

  • Wind pressure zoning: wind loads on super-tall buildings are usually calculated in height zones; wind pressure is greatest in the top zone, so the back bolt layout should be appropriately densified or larger specifications selected

  • Corner zones: negative wind pressure is greatest at building corners, so the safety factor for back bolt load capacity should be appropriately increased

  • Large-format panels: large panels require more back bolts or specifications of M8 and above

  • Wind tunnel testing: wind tunnel testing should be carried out for super-tall projects to determine accurate standard wind load values

4.2 Key selection points under seismic conditions

When a super-tall building is located in a high-intensity seismic zone, back bolt selection should focus on:

  • 9-degree rare earthquake seismic resistance: the back bolt system should pass the 9-degree rare earthquake seismic test, with acceleration of no less than 1.24g

  • Interstory drift accommodation: the back bolt system should be able to withstand a drift angle of 1/70 without damage

  • High-intensity zones (9 degrees and above): double-shear back bolts with nylon plastic spacers should be used

  • Seismic slip allowance: the seismic slip allowance of the pendant system should be at least 8mm

4.3 Comprehensive recommendations for back bolt selection in super-tall curtain walls

Project characteristicsRecommended back bolt typeRecommended materialKey requirements
Ordinary super-tall building (less than 200m, non-coastal)Hammer-in / screw-in304 stainless steelPassed seismic test
Super-tall building (greater than 200m, coastal)Hammer-in back bolt316 stainless steel9-degree seismic resistance + high salt-spray corrosion protection
High-intensity seismic zone (8 degrees and above)Hammer-in + double shear316 stainless steel9-degree rare-earthquake seismic resistance + nylon spacers
Thin-panel curtain wall (20mm or less)Screw-in back bolt304/316 stainless steelInstallation without impact stress
Thick-panel curtain wall (25mm or more)Hammer-in back bolt304/316 stainless steelHigh load capacity + large tolerance

V. Daring back bolt solutions for super-tall curtain walls

5.1 Core product advantages

Daring back bolt dry-hung systems are designed specifically for curtain wall projects involving super-tall buildings, high seismic requirements and harsh environments:

  • 9-degree rare earthquake seismic resistance: Daring back bolt dry-hung systems have fully passed Tongji University's 9-degree rare earthquake seismic test, with acceleration reaching 1.24g, delivering excellent seismic performance

  • Full product range: covering hammer-in, screw-in, cast-in and high-load back bolts

  • Two material options: 304 stainless steel (A2-70) and 316 stainless steel (A4-70/A4-80)

  • Stress-free anchoring: stress-free dry-hung anchoring of external wall panels achieved through mechanical locking

  • Panel anti-fall system: works perfectly with the back bolt dry-hung system, forming an integrated 'anchoring + protection' solution for super-tall curtain walls

5.2 Supporting service system

Daring provides a full-process service frompreparation of calculation reports, product selection and technical briefing to on-site technical support, supported by dedicated drilling machines and 6063-T6 aluminium alloy pendants, ensuring construction quality and installation accuracy. For advice on back bolt selection for super-tall curtain walls in specific projects, please consult the Daring technical team.

VI. Frequently asked questions

Q1What factors are mainly considered when selecting back bolts for super-tall curtain walls?
Four main factors are considered: wind load (basic wind pressure is usually at least 0.55kN/m²), seismic fortification (must pass the 9-degree rare earthquake seismic test), panel thickness (determines the back bolt type and specification) and corrosive environment (determines whether 304 or 316 stainless steel is used).
Q2How should one choose between screw-in and hammer-in back bolts in super-tall buildings?
For panels of 20mm or less, screw-in back bolts are preferred (no impact stress, suitable for thin panels); for panels of 25mm or more, hammer-in back bolts are selected (high load capacity, large hole tolerance and high safety factor). Daring hammer-in back bolts have passed the 9-degree rare earthquake seismic test.
Q3Should 304 or 316 stainless steel be used for back bolts in super-tall curtain walls?
For ordinary inland environments, 304 stainless steel is sufficient; for coastal environments with high salt spray and super high-rise buildings (>100m), 316 stainless steel is recommended. 316 stainless steel adds 2%~3% molybdenum, with a pitting resistance equivalent (PREN value) ≥ 24 and superior corrosion resistance.
Q4How is the seismic performance of Daring back bolts?
The Daring back bolt dry-hung cladding system has fully passed the 9-degree rare earthquake test at Tongji University, reaching an acceleration of 1.24g, and can provide reliable safety in buildings in high seismic intensity zones (intensity 9 fortification), making it especially suitable for super high-rise curtain wall projects with high seismic requirements.
Q5What is the load capacity requirement for back bolts in super high-rise curtain walls?
The specific values must be determined by calculation based on wind loads, panel dimensions, seismic fortification, and other factors. In project cases, the design tensile load capacity of a single bolt is typically 2.6-12.5kN, and for super high-rise projects the design tensile load capacity of back bolts is ≥ 12.5kN.

The Daring back bolt series covers hammer-in, screw-in, cast-in, and high-load back bolts, made of 304/316 stainless steel and achieving stress-free dry-hung anchoring of exterior wall panels through mechanical locking. The Daring back bolt dry-hung cladding system has passed the 9-degree rare earthquake test at Tongji University, reaching an acceleration of 1.24g, and is especially suitable for super high-rise curtain wall projects with high seismic requirements and demanding environments. For back bolt selection advice for a specific super high-rise curtain wall project, please contact the Daring technical team.

References

Daring official website: back bolt series products

Daring official website: Curtain Wall Anchoring Solutions

JGJ 145-2013 Technical Specification for Post-Installed Anchoring in Concrete Structures

JGJ 102-2003 Technical Specification for Glass Curtain Wall Engineering

JGJ 336-2016 Technical Specification for Artificial Panel Curtain Wall Engineering

GB 50011 Code for Seismic Design of Buildings