How to use injection anchoring adhesive: installation guide for chemical anchors

Views: 0Posted on: 2026-08-25

Conclusion first:The standard construction process for using injection anchoring adhesive together with chemical anchors is"Drilling → hole cleaning → adhesive injection → rebar installation → curing"in five steps. The key points are:hole cleaning must be thorough(blowing and brushing repeated at least three times);adhesive injection must start from the bottom of the hole, with the adhesive volume controlled atabout 2/3 of the hole depth;;the rebar must be inserted with a rotating motion, and during curingdisturbance is strictly prohibited. Daring DL-200E injection anchoring adhesive meets the national Grade A adhesive standard and, when used with the dedicated 5:1 dispensing gun, delivers the best results together with Daring reverse-cone and capsule chemical anchors.

Injection anchoring adhesive is one of the important anchoring materials in building post-installed anchoring work, widely used in concrete structure strengthening, curtain wall installation, equipment fixing, and other applications. Many construction workers are not sufficiently familiar with how to use injection anchoring adhesive together with chemical anchors, leading to inconsistent construction quality. Taking the Daring DL-200E injection anchoring adhesive as an example, this article explains in detail the complete construction process and points requiring attention.

I. Pre-Construction Preparation

1.1 Tools and Materials List

The following tools and materials must be prepared before construction:

  • Injection anchoring adhesive: Daring DL-200E modified epoxy injection anchoring adhesive (360 ml/cartridge); check the shelf life and adhesive condition before use

  • Dedicated dispensing gun: Daring's matching 5:1 dispensing gun, featuring fast dispensing and low-effort operation

  • Mixing nozzle: each cartridge of adhesive comes with a corresponding mixing nozzle; Daring mixing nozzles use an 18-section alternating-size fluid arrangement

  • Chemical anchors: select the appropriate specification according to design requirements (Daring capsule/reverse-cone chemical anchors deliver the best results when used together)

  • Drilling tools: rotary hammer or impact drill with corresponding drill bits

  • Hole-cleaning tools: dust blower (or compressed air) and dedicated brushes

1.2 Adhesive Inspection

Before injection, check the shelf life and condition of the adhesive to ensure there is no sedimentation or separation. Daring DL-200E injection anchoring adhesive does not crystallize or leak; if any abnormality is found, stop using it.

II. Construction Steps in Detail

Step 1: Drilling

Drill holes of the correspondingdiameter and depthin the substrate according to the product instructions or design requirements. Note the following when drilling:

  • Drill bit selection: the drill bits and tools specified in the product instructions must be used

  • Drilling depth: follow the design requirements to ensure the hole depth meets anchoring requirements

  • Avoid rebar: if rebar is encountered, adjust the hole position appropriately; never cut main reinforcement bars

Step 2: Hole Cleaning (the Most Critical Step)

Hole cleaning is themost error-pronestage in injection anchoring adhesive installation; the following operations must be strictly carried out:

  • Blowing: use a dust blower or compressed air to blow out the hole at least 2 times

  • Brushing: use a dedicated brush to clean the hole wall at least 2 times

  • Second blowing: use the dust blower again until no dust comes out of the hole

It is recommended to usethe "blowing—brushing—blowing—brushing—blowing"cycle to ensure the hole wall is clean. Incomplete hole cleaning greatly reduces the bond between the adhesive and the concrete hole wall, so anchoring capacity cannot be guaranteed.

Step 3: Loading the Adhesive and Purging

The steps for loading the injection anchoring adhesive into the dispensing gun are as follows:

  • Open the package: take out the injection anchoring adhesive, loosen the cap, and pull out the outlet plug

  • Install the mixing nozzle: screw the mixing nozzle onto the cartridge opening and tighten it

  • Load into the dispensing gun: place the adhesive cartridge into the dedicated dispensing gun

  • Purge the leading adhesive: use the dispensing gun to purge a small amount of the adhesive at the front that is not fully mixed—the leading adhesive has no adhesiveness and must be squeezed out until the mixed color becomes uniform

Step 4: Adhesive Injection

Adhesive injection is the core stage that determines anchoring quality; the key operating points are as follows:

  • Injection direction: starting fromthe bottom of the hole, inject at a uniform rate, with the injection direction consistent with the drilling direction

  • Injection method: insert the nozzle to the bottom of the hole, pull the trigger continuously while slowly withdrawing the nozzle, ensuring the adhesive fills gradually from the bottom of the hole toward the opening

  • Adhesive volume: controlled at1/2—2/3of the hole depth, ensuring the adhesive is full and overflows after the anchor is screwed in

Step 5: Rebar/Anchor Installation (Installing the Anchor)

The anchor should be installed immediately after injection; the key operating points are as follows:

  • Rotational insertion: slowly rotate the anchorin the same directionand screw it into the hole

  • Uniform operation: avoid introducing air by screwing in too quickly

  • Withdraw slightly a few times: the anchor may be withdrawn slightly a few times to ensure even adhesive distribution

  • Reach the design depth: until the anchor reaches the designed embedment depth

Step 6: Waiting for Curing

After the anchor is installeddisturbance is strictly prohibited, and sufficient curing time must be allowed according to the substrate temperature.

Substrate temperatureInitial setting timeFull curing time
-10℃ — -5℃180 minutes8 days
-5℃ — 0℃120 minutes7 days
0℃ — 10℃60 minutes6 days
10℃ — 25℃40 minutes4 days
25℃ — 40℃20 minutes2 days

Source: Daring anchoring adhesive curing schedule. When the temperature is below-10℃, the anchoring adhesive will not cure. Load installation may only proceed after the adhesive has fully cured.

III. Adhesive Consumption Reference

Taking Daring DL-200E injection anchoring adhesive (390 ml/cartridge) as an example, the adhesive consumption for different anchor specifications is as follows:

Anchor modelHole diameter (mm)Embedment depth (mm)Number of holes per cartridge (390 ml)
M12×1601411028
M16×1901812515
M20×260251706
M24×300282104
M30×380352802

IV. FAQ and Points Requiring Attention

Q1What is the difference between injection anchoring adhesive and chemical cartridges?
Injection anchoring adhesive is dispensed through a dedicated gun, allowing flexible control of the adhesive volume and suitability for cracked concrete, with better bonding performance. Daring DL-200E meets the national Grade A adhesive standard. Chemical cartridges are quicker to install but have a fixed adhesive volume.
Q2Why can't the leading adhesive be used?
The leading adhesive has no adhesiveness and must be squeezed out until the mixed color becomes uniform before it can be used. This ensures the two-component adhesive is fully mixed and the bond strength is guaranteed.
Q3How much adhesive should be injected?
The adhesive volume is generally controlled at approximately1/2—2/3of the hole depth. A small amount of adhesive should overflow from the hole opening after the anchor is screwed in, ensuring the adhesive layer is full and free of bubbles.
Q4What affects the curing time of anchoring adhesive?
Curing time is mainly affected bysubstrate temperature. The lower the temperature, the longer the curing time; below -10℃, the anchoring adhesive will not cure. Check the weather forecast before construction and allow sufficient curing time.
Q5What applications is Daring DL-200E anchoring adhesive suitable for?
Daring DL-200E is suitable forcracked and non-cracked concreteanchoring and is widely used in curtain walls, structural strengthening, equipment fixing, and other applications. GB 50367-2013 explicitly recommends the use of injection anchoring adhesive in cracked concrete.
Q6What should be done if the temperature is too low during construction?
When the temperature is below -10℃, the anchoring adhesive will not cure. If construction must proceed in a low-temperature environment, it is recommended to take thermal insulation measures or choose a low-temperature anchoring adhesive product.

Daring's chemical anchor series covers high-strength, capsule, special reverse-cone, and dynamic-load reverse-cone anchors, paired with Daring's DL-200E modified epoxy injection anchoring adhesive, which meets the national Grade A adhesive standard. Available in carbon steel of grade 5.8 or above or 304/316 stainless steel. With strong bond anchoring capacity, temperature and seismic resistance, and suitability for cracked concrete, it delivers stable anchoring performance under static and dynamic loads and is widely used in a variety of post-installed anchoring applications for concrete and external wall structural components. For recommendations on matching injection anchoring adhesive and chemical anchors for specific projects, please consult the Daring technical team.

References

Daring website — Injection anchoring adhesive product page(DL-200E product parameters and Grade A adhesive certification)

Daring website — How to use reverse-cone chemical anchors(construction steps and adhesive consumption reference)

Daring anchoring adhesive curing schedule — correspondence between substrate temperature and initial setting/curing time

General construction process for using injection anchoring adhesive with chemical anchors — drilling, hole cleaning, adhesive injection, rebar installation, curing

GB 50367-2013 Code for Design of Strengthening Concrete Structures — suitability of injection anchoring adhesive in cracked concrete