Product Knowledge

Curtain wall anchor materials and surface treatment processes explained

Views: 0Posted on: 2018-12-20

Metal anchors used in curtain walls fall into two main categories: the chemical anchor series and the mechanical anchor series. Earlier we looked at the materials of building anchors and learned that metal anchors are mostly made of carbon steel and alloy steel, with a smaller proportion of austenitic stainless steel. This article will mainly analyze the surface treatment processes for some of these materials.

Surface Treatment Processes Mentioned in the Standard

For metal anchors, there are many surface treatment processes, such as blackening, bluing, phosphating, electro-galvanizing (commonly known as cold galvanizing), hot-dip galvanizing, mechanical galvanizing, Dacromet, Teflon, Luxiubao, nickel plating, and so on. With so many surface treatment processes, how should we choose? This is truly a difficult problem. I have consulted many standards without finding any mandatory provision clearly stating which surface treatment processes are allowed and which are not. Only JGJ 145-2013, 'Technical Specification for Post-Installed Anchoring in Concrete Structures,' states the following:

4.1.2 Metal anchors shall be provided with corrosion-protection measures appropriate to the category of service environment. The surfaces of mechanical anchors made of carbon steel or alloy steel shall be galvanized for corrosion protection; the average thickness of the electro-galvanized layer shall be not less than 5 μm, and the average thickness of the hot-dip galvanized layer shall be not less than 45 μm. In outdoor environments, perennially humid indoor environments, seaside locations, and atmospheres with high acidity or alkalinity, anchors made of stainless steel shall be used; in environments containing chloride ions, highly corrosion-resistant stainless steel shall be used. The categories of anchor materials applicable under different environmental conditions may be selected according to Table 4.1.2.

Table 4.1.2 Categories of Anchor Materials Used Under Different Environmental Conditions

Environmental Condition

Category of Anchor Material Used

Normal Indoor Environment

Carbon Steel, Alloy Steel, or Stainless Steel

No significant chloride ion or

sulfide corrosion effects, and easy to repair

S30408、S30408、S32168、

Stainless steels such as S32169 and S30153

With chloride ion or sulfide corrosion effects,

and difficult to repair or costly to repair

S301608、S31603、S31668、

Stainless steels such as S31723 and S23043

Exposed to a chloride ion or sulfide corrosive environment

Stainless steels such as S34553 and S31252

Although only these few sentences mention materials and surface treatment processes, they can still serve as a basis. A brief summary yields the following conclusions:

① Metal anchors mostly use carbon steel, alloy steel, and stainless steel as processing materials;

② Mechanical anchors made of carbon steel and alloy steel must be electro-galvanized or hot-dip galvanized (no other surface treatment methods are mentioned);

③ Environments with higher corrosion-protection requirements require the use of different types of stainless steel according to the specific environment.

Because the standard does not mention surface treatment processes other than electro-galvanizing and hot-dip galvanizing, as an anchor manufacturer Daring basically only performs these two surface treatments. However, it would be wrong to say that only these two processes can be used on walls. Among the surface treatment processes mentioned above, more than one is better than cold galvanizing, yet these processes with better weather resistance are rarely used on curtain walls. The main reason is that, on the one hand, the standard has no relevant provisions, so there is a certain risk to take; on the other hand, the prices also differ — capital always seeks profit.

How to Select Anchor Materials and Surface Treatment Processes

From the table above, one can clearly see the categories of anchor materials used in different environments, which basically cover most working conditions. What I want to emphasize here, however, is the designer's intent. I have encountered a customer inquiring about undercut anchors who required a hot-dip galvanizing process and a 1,200-hour salt spray test — clearly an impossible combination. Yet many suppliers resort to any means to win orders: to pass the test, they give the product surface a special treatment before testing, but the actual delivered products receive no such treatment.

In my view, when designing a project, the designer must have a thorough understanding of the project's material properties. Absurd situations like the one above occur every day; they are truly ridiculous yet leave one powerless. Haphazard design will only put the entire project in a dangerous situation.



Back to Daring Home  Back to Top