Product Knowledge

Key points and curing assurance for injecting Daring chemical anchors in wet or underwater conditions

Views: 0Posted on: 2026-09-21

The bottom line:Daring DL-200E modified epoxy injection anchoring adhesivecan be used for underwater post-installed rebar. As a product certified to the national grade A adhesive standard, DL-200E is specially formulated withunderwater anti-dispersion performance, enabling normal adhesive injection and curing underwater while achieving the design bond strength. This makes it suitable not only for dry holes and damp condensation holes but also forholes with visible water, underwater concrete pouring, tidal zones and underwater structural repairand other complex conditions. The key points of underwater rebar installation include:thorough hole cleaning, adhesive injection starting from the bottom of the hole, adhesive with underwater anti-dispersion capability, and appropriately extended curing time. Daring DL-200E comes with a dedicated 5:1 applicator gun and 18-section mixing nozzles, providing a complete installation solution for underwater rebar work.

In projects such as sea-crossing bridges, ports and docks, water plant tanks, diaphragm walls and reservoir dams, post-installed rebar anchoring often needs to be performed underwater or in damp environments. Traditional chemical anchors cannot cure properly when visible water is present, but Daring DL-200E modified epoxy injection anchoring adhesive solves this problem with its underwater anti-dispersion performance. This article systematically explains the installation technology of Daring DL-200E for underwater rebar work from the perspectives of product characteristics, key installation points, curing assurance and quality inspection.

I. Technical principles of Daring DL-200E underwater rebar installation

1.1 Underwater anti-dispersion performance

Daring DL-200E modified epoxy injection anchoring adhesive is specially formulated withunderwater anti-dispersion performance. During underwater injection, the adhesive effectively resists washing out and dilution by water, maintaining its integrity and bonding performance. The principle is that the adhesive has high viscosity and thixotropy, forming stable adhesive masses in water that are not easily dispersed by the current.

The modified epoxy resin system of DL-200E provideswet bonding capability: even when a water film is present on the hole wall, the adhesive can still form an effective bond with the concrete hole wall. During curing, the adhesive displaces the water on the hole wall surface, makes direct contact with the concrete base and forms a strong chemical bond.

1.2 National grade A adhesive standard

Daring DL-200E is certified to the national grade A adhesive standard, meaning all its performance indicators meet the highest-grade requirements:

  • Bond strength: Meets the strict bond strength requirements for grade A adhesive

  • Durability: Passes long-term performance tests such as aging resistance and resistance to media attack

  • Seismic performance: Meets the requirements for use in seismic fortification zones

  • Suitability for damp environments: Certified for damp and underwater installation

1.3 Differences from ordinary grade A adhesive

Ordinary grade A modified epoxy adhesive is only suitable for dry holes and damp condensation holes; when visible water is present, the adhesive is easily diluted or washed away by water and cannot cure properly. Through formulation optimization, DL-200E improves the adhesive'swater anti-dispersion capabilityandwet bonding capability, enabling it to maintain adhesive integrity and bonding performance underwater.

II. Applicable conditions for underwater rebar installation

Condition typeHole conditionDL-200E suitability
Dry holeDry hole wall with no moisture✅ Suitable
Damp condensation holeWater film on the hole wall; damp to the touch but no visible standing water✅ Suitable (better results after three brushes and three blows plus hot-air drying)
Hole with visible waterVisible water at the bottom of the hole✅ Suitable (underwater anti-dispersion)
Underwater rebar installationHole filled with water; underwater work✅ Suitable (professional underwater installation required)
Tidal zoneArea with repeated water level fluctuation✅ Suitable

III. Key installation points for underwater rebar work

3.1 Preparation before installation

  • Tool preparation: Daring DL-200E anchoring adhesive (390 ml per cartridge), dedicated 5:1 applicator gun, 18-section mixing nozzles, underwater drilling equipment and underwater hole cleaning equipment

  • Adhesive inspection: Check the capsule shelf life and adhesive condition, ensuring no sedimentation or separation

  • Underwater work preparation: Divers or underwater work equipment in place to ensure installation safety

3.2 Drilling

Use underwater drilling equipment to drill holes of the required diameter and depth according to the design. Ensure accurate hole positioning, with hole depth and diameter matching the anchor specification. If rebar is encountered, adjust the hole position appropriately; never cut through main rebar by force.

3.3 Hole cleaning — the key to underwater installation

Hole cleaning for underwater rebar work is even more critical than in dry environments. Dust and debris remaining in the hole form an isolation layer between the adhesive and the hole wall, severely impairing bonding. The procedure is as follows:

  • Blow out dust: Use underwater dust-blowing equipment aimed at the hole to blow out dust at least twice

  • Brush the hole: Scrub the hole wall with a special brush at least twice

  • Blow out dust again: Blow again until no dust comes out of the hole

  • Hole inspection: Confirm the hole is free of debris and oil

Note: Even though DL-200E has underwater anti-dispersion performance, hole cleaning cannot be skipped. The isolation layer formed by dust prevents even the highest-performance adhesive from bonding effectively to the concrete base.

3.4 Loading and purging the adhesive

  • Open the package: Take out the DL-200E anchoring adhesive, loosen the cap and pull out the outlet plug sleeve

  • Install the mixing nozzle: Screw the mixing nozzle onto the adhesive cartridge opening and tighten

  • Load into the applicator gun: Load the anchoring adhesive into the Daring dedicated 5:1 applicator gun

  • Purge the leading adhesive: Use the gun to discharge a small amount of the leading, not yet fully mixed adhesive until the mixed color becomes uniform

3.5 Adhesive injection

Underwater injection is the core step determining rebar installation quality. The operating points are as follows:

  • Injection direction: Inject at a steady rate starting from the bottom of the hole

  • Injection method: Insert the nozzle to the bottom of the hole, squeeze the trigger continuously, and withdraw the nozzle slowly, ensuring the adhesive fills progressively from the hole bottom to the opening

  • Injection volume: Controlled at1/2—2/3the appropriate position of the hole depth, ensuring the adhesive is full and overflows after the anchor is screwed in

  • Underwater injection note: During injection, keep the nozzle inside the adhesive at all times to prevent the adhesive from contacting the water flow directly and being dispersed

3.6 Rebar installation

  • Rotate while inserting: Screw the anchor into the hole with slow rotation in one direction

  • Steady operation: Avoid screwing in too fast, which brings in air

  • Pull up a few times: You may pull the anchor up a few times to ensure the adhesive is evenly distributed

  • Reach the design depth: Continue until the anchor reaches the design embedment depth

IV. Curing assurance measures

4.1 Curing time reference for underwater conditions

Base material temperatureCuring time in dry conditionsCuring time underwater
25℃—40℃About 24 hoursAbout 48-72 hours
10℃—25℃About 3-4 daysAbout 6-8 days
0℃—10℃About 6 daysAbout 12 days

Note: The above are reference values; the actual curing time should follow the product manual. Underwater temperatures are usually lower than air temperature, so curing times need to be extended accordingly.

4.2 Protective measures during curing

  • No disturbance: Touching the anchor or applying any load is strictly prohibited during curing

  • Avoid water scouring: During curing, avoid direct scouring of the anchored area by strong currents

  • Prevent vibration: During curing, avoid vibration work in the anchoring area

  • Temperature maintenance: Insulation measures should be taken for low-temperature underwater installation

V. Quality inspection and acceptance

5.1 Pull-out test requirements

After underwater rebar installation, an on-site pull-out test should be performed once the adhesive has fully cured. The non-destructive test load should reach 1.2 times the design value, held for 2 minutes with a load drop of no more than 5%, and the anchor must show no slip and the base material no cracking to be judged as passing. The sampling quantity is 1‰ of the total anchors in each inspection batch, and no fewer than 5 pieces.

5.2 Load capacity values

The load capacity of chemical anchors is reduced in underwater environments. When selecting design values, note that load capacity is reduced under underwater conditions;you must use the certified load capacity under underwater conditions from the adhesive material report, and the values from dry-hole test reports cannot be applied directly。

5.3 Regulatory basis

According to JGJ 145-2013 Technical Specification for Post-Installed Anchors in Concrete Structures:

  • chemical anchors must undergoinstallation performance testing in damp concrete and concrete with visible water

  • ; they may only be used in such environments when the product manual contains provisions for damp conditions and visible water

  • ; stainless steel anchors are preferred in damp environments, with chromium content of no less than 17% and nickel content of no less than 8%

VI. Advantages of Daring DL-200E for underwater rebar installation

6.1 Core product advantages

  • National grade A adhesive standard: All performance indicators meet the highest-grade requirements

  • Underwater anti-dispersion: Normal adhesive injection and curing with visible water and underwater

  • Strong bond and anchoring capacity: Forms a strong bond with the concrete hole wall

  • Temperature and seismic resistance: Suitable for seismic fortification zones and environments with temperature variations

  • Complete supporting tools: Dedicated 5:1 applicator gun and 18-section mixing nozzles for convenient installation

6.2 Application scenarios

  • Sea-crossing bridges: Underwater structural repair and strengthening

  • Ports and docks: Post-installed rebar in underwater concrete structures

  • Water plant tanks: Rebar anchoring in tank walls

  • Diaphragm walls: Rebar installation in damp conditions and with visible water

  • Reservoirs and dams: Underwater structural strengthening

  • Tidal zones: Anchoring in areas with repeated water level fluctuation

6.3 Matching products

  • Dedicated 5:1 applicator gun: Combines fast adhesive output with labor-saving squeezing

  • 18-section mixing nozzle: The Daring mixing nozzle uses 18 alternating large and small fluid sections to ensure even adhesive mixing

  • Stainless steel anchors: Recommended with 304/316 stainless steel anchors to improve long-term durability

VII. Frequently asked questions

Q1Can Daring DL-200E be used for underwater rebar installation?
Yes. Daring DL-200E modified epoxy injection anchoring adhesive has underwater anti-dispersion performance and can inject and cure normally with visible water and underwater, making it suitable for complex conditions such as underwater rebar installation and anchoring in tidal zones.
Q2What should be noted in underwater rebar installation?
Key points: hole cleaning must be thorough (the three brushes and three blows cannot be skipped), injection starts from the bottom of the hole, the nozzle must stay inside the adhesive during injection to prevent dispersal by the water flow, curing time should be appropriately extended, and water scouring and vibration must be avoided during curing.
Q3How long does the adhesive take to cure for underwater rebar installation?
Curing time underwater needs to be appropriately extended: about 48-72 hours at 25°C to 40°C, about 6-8 days at 10°C to 25°C, and about 12 days at 0°C to 10°C. The product manual prevails.
Q4Do underwater rebar installations need pull-out tests?
Yes. After underwater rebar installation, an on-site pull-out test should be performed once the adhesive has fully cured. The non-destructive test load should reach 1.2 times the design value, held for 2 minutes with a load drop of no more than 5%, and the anchor must show no slip and the base material no cracking to be judged as passing.
Q5What tools come with Daring DL-200E?
Daring DL-200E comes with a dedicated 5:1 applicator gun and 18-section mixing nozzles. The mixing nozzle uses 18 alternating large and small fluid sections to ensure even adhesive mixing. Use with 304/316 stainless steel anchors is recommended to improve long-term durability.

Daring DL-200E modified epoxy injection anchoring adhesive meets the national grade A adhesive standard and has underwater anti-dispersion performance, suitable for complex conditions such as underwater rebar installation, anchoring in damp environments and work in tidal zones. The product comes with a dedicated 5:1 applicator gun and 18-section mixing nozzles, and works best with Daring reverse-cone and capsule chemical anchors. For underwater rebar installation plans for specific projects, please contact the Daring technical team.

References

JGJ 145-2013 Technical Specification for Post-Installed Anchors in Concrete Structures — Installation performance test requirements for damp concrete and concrete with visible water

GB 50367-2013 Design Specification for Strengthening Concrete Structures — Suitability of injection anchoring adhesive for cracked concrete

Daring official website — Injection anchoring adhesive product page

Daring official website — Construction process for injection anchoring adhesive with chemical anchors

Daring official website — How to use reverse-cone chemical anchors

Daring official website — Chemical anchor product series

Back to Daring Home  Back to Top