Product Knowledge

What electrogalvanized coating thickness is acceptable on anchoring components

Views: 0Posted on: 2019-08-23

Electro-galvanizing, also called cold galvanizing, is a surface treatment process that uses electrolysis to form a uniform, dense, well-bonded metallic or alloy deposit on the article's surface. For environments with low corrosivity, electro-galvanizing is more cost-effective; in fact, shipment volumes of electro-galvanized anchors far exceed those of anchors with other surface treatments.

Classification of electro-galvanizing conversion coatings

The electro-galvanizing process involves more than forming a zinc electroplate on the article's surface; the surface also requires conversion treatment. Regarding electro-galvanizing conversion coatings, GB/T 9799-2011 Metallic and Other Inorganic Coatings—Electroplated Coatings of Zinc with Subsequent Treatments on Iron and Steel contains the following statement:

A.1 General

Chromate conversion solutions are usually acidic, may contain hexavalent or trivalent chromium, and contain other salts that improve the appearance and hardness of the film. With appropriate post-treatment, zinc electroplated coatings can obtain bright, bleached, iridescent, olive-green, and black films. White films can also be obtained by bleaching iridescent films in alkaline or phosphoric acid solutions. Table C.1 gives guidance on suitable films. Table A.1 lists the approximate surface density (mass per unit area) of each class of chromate conversion coating measured according to ISO 3892.

Table A.1 Types, appearance, and surface density of chromate conversion coatings

Type

Typical appearance

Film surface density

ρA/(g/m²)

Code

Name

A

Bright film

Clear, clear to light blue

ρA≤0.5

B*

Bleached film

White with a slight iridescence

ρA≤1.0

C

Iridescent film

Yellowish iridescence

0.5<ρA<1.5

D

Opaque film

Olive green

ρA>1.5

F

Black film

Black

0.5≤ρA≤1.0

Note: The descriptions of chromate coatings in this table do not necessarily refer to improved adhesion of paint and varnish. All chromate films may or may not contain hexavalent chromium ions.

* This is a two-step process.

In other words, after electro-depositing the zinc coating from acid zinc chloride, alkaline non-cyanide zinc, or alkaline cyanide zinc solutions, the article must also receive the corresponding chromate conversion coating on its surface to increase corrosion resistance. The main chromate conversion coatings are shown in the table above; types A and C surface conversion coatings are commonly used for anchors, and Daring uses only the type A zinc coating conversion.

Corrosion resistance of each conversion coating

Annex C of the standard above details the corrosion resistance of the various electro-galvanized + conversion coatings as follows:

C.1 Corrosion resistance of zinc electroplated coatings + chromate conversion coatings in severe salt spray tests

Table C.1 gives the corrosion resistance of zinc electroplated coatings + chromate conversion coatings in neutral salt spray tests under different service conditions.

Table C.1 Corrosion resistance of zinc electroplated coatings + chromate conversion coatings in neutral salt spray tests

Coating designation

(partial)

Service condition number

Service condition

Severe salt spray test duration/h

Fe/Zn5/A

Fe/Zn5/B

Fe/Zn5/F

0

Entirely decorative

48

Fe/Zn5/C

Fe/Zn5/D

Fe/Zn8/A

Fe/Zn8/B

Fe/Zn8/F

1

Warm, dry interior

72

Fe/Zn8/C

Fe/Zn8/D

Fe/Zn12/A

Fe/Zn12/F

2

Interior with possible condensation

120

Fe/Zn12/C

Fe/Zn12/D

Fe/Zn25/A

Fe/Zn25/F

3

Outdoor, ambient conditions

192

Fe/Zn25/C

Fe/Zn25/D

4

Outdoor, severely corrosive

(e.g., marine or industrial environments)

360

For certain important applications at service condition 3, a minimum zinc electroplate thickness of 14um is recommended instead of 12um. For threaded articles with a diameter below 20mm, a minimum coating thickness of 10um is recommended; for articles such as rivets, tapered pins, cotter pins, and washers, a minimum coating thickness of 8um is recommended.

A brief explanation: Fe/Zn5/A represents a 5um zinc electroplate (Zn5) on iron or steel (Fe) with a bright chemical conversion treatment (A), and the others follow the same pattern. Evidently, the type A bright film in the table covers the most service scenarios, which is the main basis for Daring performing only type A bright film surface treatment. The table gives the corresponding service scenarios, and anchors are mostly used outdoors at service condition 3 or below. Generally, threaded articles with a diameter above 20mm have a minimum coating thickness of 12um, those below 20mm can use 10um, and for more severely corrosive scenarios we recommend hot-dip galvanized surface treatment or anchors made directly of 304 or 316 stainless steel.

Other requirements

Beyond electro-galvanizing conversion coating thickness, some projects may have other requirements, such as appearance, post-treatment sealing, and sampling inspection. GB/T 9799-2011 Metallic and Other Inorganic Coatings—Electroplated Coatings of Zinc with Subsequent Treatments on Iron and Steel describes these in considerable detail, and the designer may refer to it selectively according to specific needs.




Back to Daring Home  Back to Top