Product Knowledge

How long is an anchor test report valid?

Views: 0Posted on: 2018-08-31

The validity period of anchor test reports is something I doubt most people in the building materials industry fully understand, let alone purchasing staff who only handle procurement. Here we will analyze this issue in depth so that everyone who reads this article can have a satisfactory answer.

Classification of anchors

As we know, anchors can be divided by anchoring principle into chemical adhesive anchors and mechanical anchors, but the classification discussed here follows national standards.

Clause 4.1.2 of JG/T 160-2017 'Mechanical Anchors for Concrete' that I could find is as follows:

4.1.2 Classified by application conditions as follows (see Table 1):

Anchors for use in non-cracked concrete, designated N;

Anchors that can be used in both non-cracked and cracked concrete, designated C;

Anchors that can be used in both non-cracked and cracked concrete and can withstand seismic action, designated S.

Table 1 Anchor application conditions

Application conditions

Anchor application condition type

Type N anchor

Type C anchor

Type S anchor

Non-cracked concrete

√

√

√

Non-cracked and cracked concrete

—

√

√

Non-cracked and cracked concrete subject to seismic action

—

—

√

Note: √ indicates suitable application conditions for the anchor

Since this standard applies only to mechanical anchors, and understanding the difference between undercut anchors and expansion anchors, we can make a simple classification of mechanical anchors. Undercut anchors can be used in non-cracked and cracked concrete and under seismic action, so they should be Type S anchors. Expansion anchors cannot be used in load-bearing structures, and must not be used on curtain walls due to their poor seismic capability, so they can be classified as Type N anchors.

Validity period of type test reports

Still referring to the aforementioned standard, section 8.1 of JGT 160-2017 'Mechanical Anchors for Concrete' stipulates:

8.1.1 Factory inspection

Factory inspection items are shown in Table 4, and the number of inspection samples for each specification shall be no fewer than 5.

Table 4 Factory inspection and type inspection items

Test item number

Anchorage performance test items

Factory inspection items

Type inspection items

Type N

Type C

Type S

Type N

Type C

Type S

1

Reference tension test in non-cracked concrete

√



√

√

√

2

Reference shear test in non-cracked concrete




√

√

√

3

Tension performance test in 0.3 mm cracked concrete


√



√

√

4

Shear performance test in 0.3 mm cracked concrete





√

√

5

Concrete strength adaptability test




√

√

√

6

Ultimate installation torque performance test




√

√

√

7

Cyclic crack opening and closing tension performance test





√

√

8

Tension performance test in 0.8 mm cracked concrete



√



√

9

Shear performance test in 0.8 mm cracked concrete






√

10

Variable-amplitude pulsating tensile load performance test






√

11

Variable-amplitude cyclic shear load performance test






√

12

Crack variable-amplitude cyclic opening and closing tension performance test






√

13

Radial force coefficient of undercut anchors






√

Note: √ indicates that the test shall be carried out.

8.1.2 Type inspection

All anchor products used in China shall undergo type inspection by a domestic quality supervision and inspection institution qualified to inspect anchors; the inspection items are shown in Table 4. Type inspection shall be carried out when any of the following circumstances occurs:

a) Finalization appraisal of new products;

b) After formal production, when changes in product design, materials, workmanship, production equipment, management, etc. may affect product performance;

c) During normal production, Type N and Type C anchors are inspected periodically every 3 years, and Type S anchors every 5 years;

d) Production is transferred to another factory, or production resumes after being suspended for more than 1 year.

As can be seen from the standard,Expansion anchors, as Type N anchors, require periodic inspection every 3 years, while undercut anchors are inspected every 5 years.Of course, this applies only to type inspection. However, referring to Table 4 in the standard, one can see that Type S anchors have a great many type inspection items, so naturallythe cost is not affordable for ordinary enterprises, and the vast majority of domestic companies would not consider carrying out such an inspection every 5 years.

Which category do chemical adhesive anchors belong to?

I have reviewed various standards but never found any clause concerning the inspection interval for chemical anchors, so it is naturally difficult to determine the validity period of their test reports. If the provisions for mechanical anchors could be applied, then ordinary high-strength chemical anchors would be Type N or Type C anchors, while reverse-cone anchors and capsule anchors used with anchoring adhesive could be regarded as Type S anchors, with inspection intervals referring to the above. Of course, this is not rigorous and naturally cannot be used as a basis for determination; it is hoped that the country will issue a more comprehensive standard to resolve this issue.

Common entrusted test reports in practice

Most people may be completely unaware of the existence of type reports; what they know is mostly 'entrusted inspection', which is one of the most common test reports in practice. To clarify the relationships among the various reports, the author consulted several national testing institutions and received the following reply: reports are divided into four types—type inspection, entrusted inspection, witness inspection, and sampling inspection. The first is a comprehensive inspection, while the latter three are single-item or multi-item inspections developed according to customer needs. Entrusted inspection reports state 'valid only for the samples submitted', whereas witness inspection and sampling inspection state 'valid only for the current batch of anchors'.

Entrusted inspection, witness inspection, and sampling inspection have no notion of a validity period, because the groups they target are limited. The explanation given by the testing institute is that the report database has a validity period of 5 years, during which the report data can be retrieved. The entrusted test reports widely used in the industry ultimately only have reference value. So how can product quality be ensured? The author can offer a corresponding method:After the manufacturer provides an entrusted test report, conduct sampling inspection on a certain proportion (for example, 0.5‰) of the products delivered to the site to determine whether the batch of anchors is qualified.



Back to Daring Home  Back to Top